• Title/Summary/Keyword: standard gas

Search Result 1,414, Processing Time 0.025 seconds

A Study on Estimation of Noise Damage caused by Rupture of Butane-can(volume : 34g)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Choi, Seong-Joo;Lee, Jong-Rark;Lim, Dong-Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.13-17
    • /
    • 2007
  • It is very insecure to treat a butane can for cooking out of door. The human injury from the accidents of butane cans has been getting increased 1.5 times yearly since 2003. In this context, the Institute of Gas Technology Training in Korea Gas Safety Corporation carries out explosion experiment to make trainees to take all possible measures to ensure safe management of gas in the field by fully recognizing the hazards of gas explosion accidents. This study intends to examine the influence of such explosion experiments on the trainees witnessing nearby. The GEN exposed to the active students participating in the experiment away from 25 meters from the explosion site was 57.94 dB and the GEN to the passive students not participating away from 50 meters was 51.92 dB. According to Weber-Fechner's law for the lower value than 65 dB which is the environmental standard, it is safe from the place 15 meter far from the explosion place. The environmental standard of offices is 50 dB, and it is lower than the environmental standard if the office is 65 meter far from the explosion place.

  • PDF

An Experimental Study on Thermal Efficiency Characteristics with Propane-DME Mixture Ratio for Residential Gas Range (Propane-DME 혼합비율에 따른 가정용 가스레인지의 열효율 특성에 관한 실험적 연구)

  • Ahn, Jae-Uk;Hwang, Hyun-Cheol;Kim, Young-Gyu;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.81-84
    • /
    • 2008
  • In this paper, the research was applied the mixture gas of Propane-DME (dimethyl ether) for being commercialization to residential gas ranges. In order to examine a correspondence between Korean Standard and thermal efficiency characteristics at each burner, experiments were performed with 100% Propane and the mixture gas of 80% Propane-20% DME. The experimental results were shown that the higher a mixture ratio of DME was used, the lower a thermal efficiency was gained. Those were due to low caloric value of DME. With 80% Propane-20% DME mixture gas, one of residential gas ranges was not satisfied the condition for the thermal efficiency value, 40%, Korean Standard. Consequently, the research needs about the standard for being commercialization to the mixture gas of Propane-DME.

  • PDF

A Study on the Development of Safety Standard through the Risk Assessment for Fuel Cell System Applied to UAV (무인 비행체용 연료전지 시스템 위험요소 분석을 통한 안전기준 개발 연구)

  • TAEHEON KIM;JAEUK CHOI;INROK CHO;JUNGWOON LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.56-65
    • /
    • 2024
  • Fuel cell powered unmanned aerial vehicles (UAV) are globally being developed for various application according to hydrogen roadmap. However, safety standards for hydrogen fuel cell for UAV have not been established. Therefore, in this study, we derive safety data based on risk assessment to develop safety standards for fuel cells for UAV. We use fault tree analysis method which is broadly used in hydrogen facilities as a risk assessment tool. We set hydrogen leaks and fires as top events and derived the basic events. Safety data for the basic events were derived by quoting overseas safety standards related to fuel cells. The safety data will be used for developing fuel cell inspection standard according to Act on Hydrogen Economy Promotion and Hydrogen Safety Management.

Development of Primary Reference Gas Mixtures for Liquid Propane (혼합 액체 프로판 표준가스 개발)

  • Jeong, Yun-sung;Kim, Jin-seog;Bae, Hyun-kil;Kang, Ji-hwan;Lee, Seung-ho;Kim, Yong-doo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.49-56
    • /
    • 2021
  • Liquefied Petroleum Gas is divided into liquefied gases containing propane (C3H8) and butane (C4H10). The quality of LPG varies greatly depending on the composition of the mixture, so it is important to measure the composition accurately. It is difficult to determine the composition of the mixture because liquid and gas coexist at room temperature. Therefore, the uncertainty in determining the concentration of hydrocarbons by component is high, and there are many problems that differ from the actual content standard. Therefore, it is necessary to develop a mixed liquid propane standard gas for the composition and accurate concentration of hydrocarbon substances. Mixed liquid propane standard gas is manufactured into bellows-type constant-pressure cylinders by ISO-6142 (2015). The homogeneity of the four standard gases manufactured was confirmed to be GC-FID. The manufacturer's uncertainty of expansion was 0.01 % to 0.30 % and homogeneity was 0.03 % to 0.25 %. In this mixed liquid propane standard gas, the relative expansion uncertainty of weight method, manufacturing consistency, cylinder adsorption and long-term stability was developed within 0.26 %-1.3 9% (95% of confidence level, k=2).

Development of Standard Checklist for Safety Management of Toxic Gas facility in Domestic University Laboratory (국내 대학 실험실 독성가스 시설의 안전관리를 위한 표준 체크리스트 개발)

  • Lee, Sungjin;Kim, Byung-Duk;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.92-98
    • /
    • 2015
  • Toxic gases are managed by High Pressure Gas Safety Control Act. Toxic Gases are "31 designated species and each gas of which the permissible concentration($LC_{50}$) is equal to or less than 5000 ppm as defined in High Pressure Gas Safety Control Act.". Korean toxic gas usage in accordance with the growth of the electronic industry has increased explosively. The demand of toxic gas research in domestic university laboratories has grown together. But the research associated with toxic gas safety management in the domestic laboratory is nonexistent state. In this study, we identified weak points of toxic gas safety management through a survey of domestic university laboratory facilities. This paper presented toxic gas safety measures in order to overcome those weak points. Also this paper developed a standard checklist to improve and ensure safe management of toxic gas facility in accordance with the proposed measures. This research is to enforce safety management of toxic gas facilities in domestic university laboratory and it will provide safety guidelines for every laboratory.

Supplementation of Regulation on the Offshore Oil Pipeline for Maintenance (해저 송유배관 유지관리를 위한 기준 보완 제시)

  • Kang, Chan-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.70-81
    • /
    • 2012
  • The study aims to supplement facility management plan and safety regulations & standard of oil pipeline by searching and reviewing related regulation & standard inside and outside of the country. Korean regulation & standard is reviewed based on harbor and fishery design standard of the ministry of maritime affairs and fisheries, general technology standard of oil pipeline safety regulation, gas excavation construction and safety maintenance indicator of Korea gas corporation. Global regulation & standard is reviewed based on U.S standard inspection for offshore pipeline and Europe/Mexico standard inspection for offshore pipeline. The contents of offshore pipeline installation is inserted into pipeline sector for objected facilities of safety inspection regulation & standard and, the standard of safety inspection for offshore pipeline is newly presented into pipeline maintenance part of the planning facilities management with its inspection period and method.

  • PDF

A study on the Prediction of Explosion Risk for the Low Pressure Natural Gas Facilities with Different Explosion Conditions (저압 도시가스 사용설비의 누출 조건에 따른 폭발 위험 분위기 형성 범위 예측에 관한 연구)

  • Han, Sangil;Lee, Dongwook;Hwang, Kyu-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.59-65
    • /
    • 2016
  • It is imperative to use suitable explosion proof equipments to prevent explosion in different gas facilities. There is no technical standard for the classification of hazardous areas though standard of explosion proof is regulated. In this study, we have adopted Industrial Standard KS to develop the methodology for the prediction of the explosion risk in the natural gas facility with low pressure using the important factors including hole size, hypothetical volume, validation of ventilation effectiveness. The applicability of the developed methodology was evaluated by the comparison with the data obtained from experiments of natural gas explosion.

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

The Analytical Bias of Total Hydrocarbon (THC) Measurements in Relation to the Selection of Standard Gas Compound (총탄화수소의 계측에서 표준시료성분의 선택에 따른 오차 발생 연구)

  • Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.449-452
    • /
    • 2010
  • In this article, the performance of the THC analyzer was inspected using two different span gases of methane ($CH_4$) and propane ($C_3H_8$). To explore the effect of standard gas selection, MicroFID system was tested by the following procedures. Initially, the system is spanned by propane gas of 60 ppm (or 180 ppmC). The system is then run against methane standards prepared at 5 different concentrations of 200, 250, 300, 400, and 500 ppm. According to the suggestion of the KMOE's test procedure to use multiplying a factor of 3 (for propane), the resulting THC values derived by methane standards were systematically biased with ~500% error relative to true value. This paper discusses the interpretation procedures to obtain the least biased THC values for a given span set-up.

Simultaneous Determination of (-)-Menthone and (-)-Menthol in Menthae Herba by Gas Chromatography and Principal Component Analysis

  • Kim, Jung-Hoon;Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.16 no.3
    • /
    • pp.180-184
    • /
    • 2010
  • The simple and accurate method was established for the simultaneous determination of (-)-menthone and (-)-menthol in Menthae herba obtained from Korea and China. A quantitative analysis was performed with a gas chromatography-flame ionization detector and reference compounds were separated on a capillary HP-Innowax column (30 m $\times$ 0.23 mm, 0.50 ${\mu}m$, Agilent, MA, USA). The correlation coefficients of the compounds showed good linearity ($r^2$ > 0.9997) over the linear range. The precision, repeatability and stability showed less than 1.7% of relative standard deviation (RSD) values for two compounds. Recovery rates were within the range of 95.72 - 103.76%. The method was applied successfully to analyze 15 samples of Menthae herba and achieved sufficient and specific separation of reference compounds. The principal component analysis (PCA) exhibited the classification of 15 samples according to their locations of origin.