• Title/Summary/Keyword: standard for application

Search Result 4,026, Processing Time 0.038 seconds

Improvement of Personal Information Protection Laws in the era of the 4th industrial revolution (4차 산업혁명 시대의 개인정보보호법제 개선방안)

  • Choi, Kyoung-jin
    • Journal of Legislation Research
    • /
    • no.53
    • /
    • pp.177-211
    • /
    • 2017
  • In the course of the emergence and development of new ICT technologies and services such as Big Data, Internet of Things and Artificial Intelligence, the future will change by these new innovations in the Fourth Industrial Revolution. The future of this fourth industrial revolution will change and our future will be data-based society or economy. Since there is personal information at the center of it, the development of the economy through the utilization of personal information will depend on how to make the personal information protection laws. In Korea, which is trying to lead the 4th industrial revolution, it is a legal interest that can not give up the use of personal information, and also it is an important legal benefit that can not give up the personal interests of individuals who want to protect from personal information. Therefore, it is necessary to change the law on personal information protection in a rational way to harmonize the two. In this regard, this article discusses the problems of duplication and incompatibility of the personal information protection law, the scope of application of the personal information protection law and the uncertainty of the judgment standard, the lack of flexibility responding to the demand for the use of reasonable personal information, And there is a problem of reverse discrimination against domestic area compared to the regulated blind spot in foreign countries. In order to solve these problems and to improve the legislation of personal information protection in the era of the fourth industrial revolution, we proposed to consider both personal information protection and safe use by improving the purpose and regulation direction of the personal information protection law. The balance and harmony between the systematical maintenance of the personal information protection legislation and laws and regulations were also set as important directions. It is pointed out that the establishment of rational judgment criteria and the legislative review to clarify it are necessary for the constantly controversial personal information definition regulation and the method of allowing anonymization information as the intermediate domain. In addition to the legislative review for the legitimate and non-invasive use of personal information, there is a need to improve the collective consent system for collecting personal information to differentiate the subject and to improve the legislation to ensure the effectiveness of the regulation on the movement of personal information between countries. In addition to the issues discussed in this article, there may be a number of challenges, but overall, the protection and use of personal information should be harmonized while maintaining the direction indicated above.

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

A Study on the Characteristics of Ca(OH)2 According to the Calcination Conditions of Oyster Shells and Its Application for Exterior Water Paints (굴 패각의 소성 조건에 따른 소석회의 특성과 외부용 수성 도료 적용 연구)

  • Hwang, Dae Ju;Yu, Young Hwan;Han, Chang Soo;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.594-605
    • /
    • 2022
  • CaO was prepared by calcining for oyster shells using a microwave kiln. It was analyzed to Ca(OH)2 synthed on hydration reaction from prepared CaO. The synthesized Ca(OH)2 was formulated as an external water paint. Oyster shells (325 mesh, 43 ㎛) were decarbonized for (a) 950 ℃/1 hr and (b) 1,150 ℃/1 hr to prepare CaO. In the calcination condition of (a), CaO was 56.7 wt%, and in the calcination condition of (b), CaO was 100 wt%. To compare CaO by calcination of oyster shells with that of limestone, limestone (25~30 mm) was decarbonized at 950 ℃/1 hr to prepare CaO, and as a result of the analysis(XRD), it was analyzed as CaO 100 wt%. CaO was prepared under the calcining conditions of oyster shells (b) 1,150 ℃/1 hr, and Ca(OH)2 was synthesized through hydration. Hydration conditions of the prepared CaO were (a) CaO : H2O(100 g : 200 g) and (b) CaO : H2O(100 g : 400 g). As a result of the hydration reaction, it was confirmed as low reactivity. 100 wt% of Ca(OH)2 was synthesized. In particular, Ca(OH)2 synthesized under the hydration condition of (a) was analyzed in a plate shape. An external water paint was formulated with Ca(OH)2 synthesized from oyster shells as the main component. When 15 items of the external water paint standard specification (KS M 6010) were analyzed, it was confirmed that all other criteria were satisfied except for freezing stability.

Estimation of Fractional Urban Tree Canopy Cover through Machine Learning Using Optical Satellite Images (기계학습을 이용한 광학 위성 영상 기반의 도시 내 수목 피복률 추정)

  • Sejeong Bae ;Bokyung Son ;Taejun Sung ;Yeonsu Lee ;Jungho Im ;Yoojin Kang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.1009-1029
    • /
    • 2023
  • Urban trees play a vital role in urban ecosystems,significantly reducing impervious surfaces and impacting carbon cycling within the city. Although previous research has demonstrated the efficacy of employing artificial intelligence in conjunction with airborne light detection and ranging (LiDAR) data to generate urban tree information, the availability and cost constraints associated with LiDAR data pose limitations. Consequently, this study employed freely accessible, high-resolution multispectral satellite imagery (i.e., Sentinel-2 data) to estimate fractional tree canopy cover (FTC) within the urban confines of Suwon, South Korea, employing machine learning techniques. This study leveraged a median composite image derived from a time series of Sentinel-2 images. In order to account for the diverse land cover found in urban areas, the model incorporated three types of input variables: average (mean) and standard deviation (std) values within a 30-meter grid from 10 m resolution of optical indices from Sentinel-2, and fractional coverage for distinct land cover classes within 30 m grids from the existing level 3 land cover map. Four schemes with different combinations of input variables were compared. Notably, when all three factors (i.e., mean, std, and fractional cover) were used to consider the variation of landcover in urban areas(Scheme 4, S4), the machine learning model exhibited improved performance compared to using only the mean of optical indices (Scheme 1). Of the various models proposed, the random forest (RF) model with S4 demonstrated the most remarkable performance, achieving R2 of 0.8196, and mean absolute error (MAE) of 0.0749, and a root mean squared error (RMSE) of 0.1022. The std variable exhibited the highest impact on model outputs within the heterogeneous land covers based on the variable importance analysis. This trained RF model with S4 was then applied to the entire Suwon region, consistently delivering robust results with an R2 of 0.8702, MAE of 0.0873, and RMSE of 0.1335. The FTC estimation method developed in this study is expected to offer advantages for application in various regions, providing fundamental data for a better understanding of carbon dynamics in urban ecosystems in the future.

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF

Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET (TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가)

  • Moon, Il-Sang;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2012
  • Purpose: To verify the optimal scan time per bed for clinical application, we evaluated the quality of $^{18}F$-FDG images with varying scan times in a phantom and 20 patients with 38 lesions using a Philips (TOF) PET/CT scanner. Materials and Methods: The PET/CT images of a NEMA IEC body phantom and 20 patients (16 males, 4 females) were acquired for 5 different scan times of 20-100 sec per bed with intervals of 20 sec. The activity ratio of hot spheres (diameter of 17 [H1], 22 [H2] and 28 [H3] mm) to the background region in the IEC body phantom was 8-to-1. The contrast recovery coefficient (CRC) and standard uptake value (SUV) based on ROIs of hot spheres and background region were calculated. The noise in each background region was estimated as the ratio of SD of counts to the mean counts in the background region. On the patient image, the injected dose of $^{18}F$-FDG was $444{\pm}74$ MBq and the SUVs in the 38 hot lesions were measured. Results: The two scan time groups (LT-60 [<60 sec] and GT-60 [${\geq}60$ sec]) were compared. In the phantom study, the coefficient of deviations (CVs, %) of CRC and SUV in LT-60 (H1: 14.2 and 7.3, H2: 11.4 and 7.8, H3: 4.9 and 3.2) were higher than GT-60 (H1: 8.9 and 2.8, H1: 8.2 and 5.0, H3: 2.0 and 1.6). In the patient study, the mean CV of CRC and SUV in LT-60 (4.0) was higher than GT-60 (1.2). Conclusion: This study showed that noise increased as the scan time decreased. High noise for the scan time <60 sec per bed yielded high variation of SUV and CRC. Therefore, considering PET/CT image quality, the scan time per bed in the TOF PET/CT scanner should be at least ${\geq}60$ sec.

  • PDF

Study on Characteristics of Chemical Properties and Microbial Flora of Organic Farming Soil in Korea (유기농 토양의 화학적 특성 및 미생물상 연구)

  • Park, Kwang-Lai;Suga, Yuko;Hong, Seung-Gil;Lee, Chorong;Ahn, Minsil;Kim, Seok-Cheol;Hashimoto, Tomoyoshi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.77-83
    • /
    • 2016
  • The objectives of this study was to investigate the difference between organic-farming and conventional-farming soils relatives to soil chemical properties and microbial flora. Fifteen soil sampling sites were chosen from the certified organic upland farm, considered with its location, crop and application of organic compost types. Soil chemical properties were analyzed by standard methods established by National Institute of Agricultural Sciences, Rural Development Administration. For the soil chemical properties, the values of pH were ranged from 4.5 to 7.3. The values of electrical conductivity (EC) in the sampling sites were below 2 dS/m of convention cultivation soil. For analyzing the microbial flora, the bacillus(16S rDNA) and cladothricosis(18S rDNA) were analyzed by using PCR-DGGE (Denaturing Gradient Gel Electrophoresis) in the soil of 15 sampling sites. Cluster analysis of biodiversity index was performed by using pattern of DGGE. DGGE patterns and clustering analysis of bacterial DNA from soil extracts revealed that the bacterial community was differentiated between less than 5 years and more than 5 years depending on the cultivation history. But there was no consistent tendency between cultivation history and regional trend in the case of molds. Therefore, it would be very effective to analyze bacterial clusters of organically cultivated soils in long - term cultivated soil for more than 5 years.

ANALYSIS OF DIFFERENTIAL GENE EXPRESSION IN NORMAL, CYST AND AMELOBLASTOMA CELLS (정상, 낭종 및 법랑아세포종 세포에서의 유전자 발현 차이 분석)

  • Yang, Cheol-Hee;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.75-88
    • /
    • 2005
  • Ameloblastoma is the most commonly occurring odontogenic tumor in oral cavity. Although most are benign epithelial neoplasm, they are generally considered to be locally aggressive and destructive, exhibiting a high rate of recurrence. The biological behavior of this neoplasm is a slowly growing, locally invasive tumor without metastasis, therefore malignant neoplasm, changed its histological appearance to carcinoma or showed distant metastasis, is only defined clinically. In this study, we identified the differentially expressed genes(DEGs) in stages under benign or malignant ameloblastoma compared with normal patient using ordered differential display(ODD) reverse transcription(RT)-PCR and $GeneFishing^{TM}$ technology. ODD RT-PCR is rather effective when the investigation of samples containing very small amounts of total RNA must be accomplished. ODD RT-PCR used the means of amplification with anchored T-primer and adaptor specific primer. bearing definite two bases at their 3' ends and so this method could display differential 3'-expressed sequence taqs(ESTs) patterns without using full-length cDNAs. Compared with standard differential display, ODD RT-PCR is more simple and have enough sensitivity to search for molecular markers by comparing gene expression profiles, However, this method required much effort and skill to perform. $GeneFishing^{TM}$ modified from DD-PCR is an improved method for detecting differentially expressed genes in two or more related samples. This two step RT-PCR method uses a constant reverse primer(anchor ACP-T) to prime the RT reaction and arbitrary primer pairs(annealing control primers, ACPs) during PCR. Because of high annealing specificity of ACPs than ODD RT-PCR, the application of $GeneFishing^{TM}$ to DEG discovery generates reproducible, authentic, and long(100bp to 2kb) PCR products that are detectable on agarose gels. Consequently, various DEGs observed differential expression levels on agarose gels were isolated from normal, benign, and malignant tissues using these methods. The expression patterns of the some isolated DEGs through ODD RT-PCR and $GeneFishing^{TM}$ were confirmed by Northern blot analysis and RT-PCR. The results showed that these identified DEGs were implicated in ameloblastoma neoplasm processes. Therefore, the identified DEGs will be further studied in order to be applied in candidate selection for marker as an early diagnosis during ameloblastoma neoplasm processes.

  • PDF

A Study on Organizational Effectiveness of Administrative Personnel in Hospitals (병원 행정직원의 조직효과성 수준)

  • Lee, Duk-Gu;Park, Eun-Cheol;Yu, Seung-Hum;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.7 no.2
    • /
    • pp.52-79
    • /
    • 2002
  • The hospital is characterized by it's remarkable labor industry and human resources input by unit. Recently, the administrative personnel are recognized as an important staff to provide a hospital guidance to consumer and also easiness for consumer's visit to hospital. The purpose of this study is to find the organizational effectiveness of the administrative personnel in hospitals. The survey data involved in the study was derived from 229 personnels working in 3 medium and small sized hospitals and 1 university hospital in Inchon area. The major finding are as follows; 1. The organizational efficiency in accordance with the general characteristics of subjects in order of over 31 years of age, university graduates, long-term tenure and high position is higher, whereas, in as much as wage and well trained personnels in are higher, general hospital's organizational efficiency is higher in comparison with those of university hospital. 2. The organizational efficiency in accordance with satisfaction and the psychological motive contributional factors is higher as much as the high satisfactory level in every hospitals in general. 3. The organizational efficiency in accordance with the factors of job characteristics is higher in as much as difficulty of the jobs is lesser, however there was not statically significance. In as much as job standard level is higher and the more job responsibility the higher organizational efficiency. It was obvious that the higher professional expertise as well as the training and application level are improving the organizational efficiency. 4. The organizational efficiency in accordance with the factors of structural characteristics was higher in as much as the intercommunication was smooth and the structural formalization level are higher, however there was not statically significance between the participation level of decision making and the organizational efficiency. 5. In as much as older age, management of organization and the job level are satisfied, the higher structural formalization level, the smooth intercommunication have affected as major influence factors of organizational efficiency. 6. In the university hospitals is satisfied in the management and job level of hospital organization as there are no difficult jobs while the level of hospital's organizational formality is high and the intercommunication is smooth, which are improving the organizational efficiency. In the general hospitals is also satisfied the management and job level of hospital organization and psychological motive contributional factors is higher, it was apparent that the organizational efficiency is higher in as much as the level of job standardization is high and the intercommunication is smooth. As a result of this study, in order for improving the organizational efficiency of administrative personnel in hospitals, the management and job level as well as personal relation are preferably satisfied, whereas formalization of organization, intercommunication and etc. should be satisfied, and, therefore, it is advisable to buildup discriminated organizational management and environment for different division on the basis above factors. Since this study is carried on four hospitals in Inchon area, there is a certain limit to generalize its result to all domestic hospitals, nevertheless the gallop poll was made by developing the questionnaires with reasonability and reliability. Especially. as the study was carried by analyzing the comparison of influence factors' difference of organizational efficiency in accordance with the divisional characteristics of the university and general hospitals.

  • PDF