• Title/Summary/Keyword: standard for application

Search Result 4,010, Processing Time 0.038 seconds

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Microbiological Safety Assessment of a Perilla Leaf Postharvest Facility for Application of a Good Agricultural Practices (GAP) System (농산물우수관리제도(GAP system) 적용을 위한 깻잎의 수확 후 관리시설(APC)에 대한 미생물학적 안전성 평가)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Lee, Hyo-Won;Shim, Won-Bo;Yoon, Yo-Han;Kim, Se-Ri;Kim, Doo-Ho;Ryu, Jae-Gee;Hong, Moo-Ki;You, Oh-Jong;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.392-398
    • /
    • 2009
  • This study identified risk factors of cross-contamination of foodborne pathogens and established a good agricultural practice (GAP) system for an agricultural products processing center (APC) for perilla leaves. All samples were collected before and after a standard work shift at the APC, while perilla leaves were also collected after each step in the APC. In addition, the workers and their surroundings were sampled by swabbing. The total plate count (TPC) and coliform count in the water samples increased significantly (p<0.05) to 3.36 and 1.73 log CFU/mL after work, respectively. However, no Escherichia coli and Listeria monocytogenes were detected. The bacterial populations of the workers and their surroundings did not differ significantly (p${\geq}$0.05) before and after work. However, Staphylococcus aureus (<1.66 log CFU) was detected at a high rate (13-50%) in the basket, packing table, gloves and cloth. Although perilla leaves passed through the washing steps, the TPC and coliform bacterial populations on the final products were higher (p${\geq}$0.05) than those of unwashed perilla leaves, which indicates that the washing system was not functioning properly. Accordingly, a GAP system with a better washing system should be employed at this facility.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Effects of Harvesting Frequency and Fertilization Levels on Botanical Composition and Forage Productivity of Alpine Grassland at 800m Altitude (산지초지를 위한 대관령 표고 800m에서 예취횟수와 시비수준이 목초의 식생구성비율, 건물수량 및 사료성분에 미치는 영향)

  • Oh, Seung Min;Kim, Ji Yun;Lee, Bae Hun;Peng, Jinglun;Chemere, Befekadu;Nejad, Jalil Ghassemi;Sung, Kyung Il;Kim, Byong Wan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.2
    • /
    • pp.124-128
    • /
    • 2016
  • The objective of this research was to determine the effects of harvesting frequency and fertilization levels on botanical composition, dry matter yield, and forage feed compositions of Alpine grassland at 800 m altitude. This research lasted for three years at National Alpine Agricultural Research Institute in Pyeongchang with two harvesting frequency schedules (two and three times annually) and two levels of fertilizer application (conventional level of fertilizer at 280-200-240 kg/ha and a lower level of fertilizer at 200-200-200 kg/ha for N, $P_2O_5$, and $K_2O$). Mixture combinations with seeding rate (kg/ha) were as follows: Orchardgrass 18, Tall fescue 9, Timothy 8, Kentucky bluegrass 3, and Ladino Clover 2. The gramineae ratio ranged from 93.2 to 95.3%. Therefore, gramineae forage was considered as the dominant plant in this experiment. No significant (p>0.05) difference was observed in forage dry matter yield between the two harvesting frequency treatments (two times at 9.8 ton/ha and three times at 8.6 ton/ha). However, forage dry matter yield in the two times of harvesting frequency tended to be greater than that in the three times of harvesting frequency. Significantly (p<0.05) higher forage dry matter yield in the standard fertilization level group than the lower fertilization level group (9.8 ton/ha vs. 8.7 ton/ha) was observed. However, there was no significant (p>0.05) difference in forage crude protein concentration between the two harvesting frequency treatment groups, although the concentration in the group with three times of harvesting frequency tended to be higher. In contrast, crude fiber concentration in the group with two times of harvesting frequency tended to be higher, although the difference was not statistically significant (p>0.05). Crude protein, ether extract, crude fiber, and organic matter concentrations were not significantly (p>0.05) different between the two groups with different fertilization levels. Based on these results, it was concluded that the group with two times of harvesting frequency with conventional fertilization level might be proper for obtaining better forage productivity for Alpine grassland at 800 m altitude.

Improvement of Personal Information Protection Laws in the era of the 4th industrial revolution (4차 산업혁명 시대의 개인정보보호법제 개선방안)

  • Choi, Kyoung-jin
    • Journal of Legislation Research
    • /
    • no.53
    • /
    • pp.177-211
    • /
    • 2017
  • In the course of the emergence and development of new ICT technologies and services such as Big Data, Internet of Things and Artificial Intelligence, the future will change by these new innovations in the Fourth Industrial Revolution. The future of this fourth industrial revolution will change and our future will be data-based society or economy. Since there is personal information at the center of it, the development of the economy through the utilization of personal information will depend on how to make the personal information protection laws. In Korea, which is trying to lead the 4th industrial revolution, it is a legal interest that can not give up the use of personal information, and also it is an important legal benefit that can not give up the personal interests of individuals who want to protect from personal information. Therefore, it is necessary to change the law on personal information protection in a rational way to harmonize the two. In this regard, this article discusses the problems of duplication and incompatibility of the personal information protection law, the scope of application of the personal information protection law and the uncertainty of the judgment standard, the lack of flexibility responding to the demand for the use of reasonable personal information, And there is a problem of reverse discrimination against domestic area compared to the regulated blind spot in foreign countries. In order to solve these problems and to improve the legislation of personal information protection in the era of the fourth industrial revolution, we proposed to consider both personal information protection and safe use by improving the purpose and regulation direction of the personal information protection law. The balance and harmony between the systematical maintenance of the personal information protection legislation and laws and regulations were also set as important directions. It is pointed out that the establishment of rational judgment criteria and the legislative review to clarify it are necessary for the constantly controversial personal information definition regulation and the method of allowing anonymization information as the intermediate domain. In addition to the legislative review for the legitimate and non-invasive use of personal information, there is a need to improve the collective consent system for collecting personal information to differentiate the subject and to improve the legislation to ensure the effectiveness of the regulation on the movement of personal information between countries. In addition to the issues discussed in this article, there may be a number of challenges, but overall, the protection and use of personal information should be harmonized while maintaining the direction indicated above.

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

A Study on the Characteristics of Ca(OH)2 According to the Calcination Conditions of Oyster Shells and Its Application for Exterior Water Paints (굴 패각의 소성 조건에 따른 소석회의 특성과 외부용 수성 도료 적용 연구)

  • Hwang, Dae Ju;Yu, Young Hwan;Han, Chang Soo;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.594-605
    • /
    • 2022
  • CaO was prepared by calcining for oyster shells using a microwave kiln. It was analyzed to Ca(OH)2 synthed on hydration reaction from prepared CaO. The synthesized Ca(OH)2 was formulated as an external water paint. Oyster shells (325 mesh, 43 ㎛) were decarbonized for (a) 950 ℃/1 hr and (b) 1,150 ℃/1 hr to prepare CaO. In the calcination condition of (a), CaO was 56.7 wt%, and in the calcination condition of (b), CaO was 100 wt%. To compare CaO by calcination of oyster shells with that of limestone, limestone (25~30 mm) was decarbonized at 950 ℃/1 hr to prepare CaO, and as a result of the analysis(XRD), it was analyzed as CaO 100 wt%. CaO was prepared under the calcining conditions of oyster shells (b) 1,150 ℃/1 hr, and Ca(OH)2 was synthesized through hydration. Hydration conditions of the prepared CaO were (a) CaO : H2O(100 g : 200 g) and (b) CaO : H2O(100 g : 400 g). As a result of the hydration reaction, it was confirmed as low reactivity. 100 wt% of Ca(OH)2 was synthesized. In particular, Ca(OH)2 synthesized under the hydration condition of (a) was analyzed in a plate shape. An external water paint was formulated with Ca(OH)2 synthesized from oyster shells as the main component. When 15 items of the external water paint standard specification (KS M 6010) were analyzed, it was confirmed that all other criteria were satisfied except for freezing stability.

Estimation of Fractional Urban Tree Canopy Cover through Machine Learning Using Optical Satellite Images (기계학습을 이용한 광학 위성 영상 기반의 도시 내 수목 피복률 추정)

  • Sejeong Bae ;Bokyung Son ;Taejun Sung ;Yeonsu Lee ;Jungho Im ;Yoojin Kang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.1009-1029
    • /
    • 2023
  • Urban trees play a vital role in urban ecosystems,significantly reducing impervious surfaces and impacting carbon cycling within the city. Although previous research has demonstrated the efficacy of employing artificial intelligence in conjunction with airborne light detection and ranging (LiDAR) data to generate urban tree information, the availability and cost constraints associated with LiDAR data pose limitations. Consequently, this study employed freely accessible, high-resolution multispectral satellite imagery (i.e., Sentinel-2 data) to estimate fractional tree canopy cover (FTC) within the urban confines of Suwon, South Korea, employing machine learning techniques. This study leveraged a median composite image derived from a time series of Sentinel-2 images. In order to account for the diverse land cover found in urban areas, the model incorporated three types of input variables: average (mean) and standard deviation (std) values within a 30-meter grid from 10 m resolution of optical indices from Sentinel-2, and fractional coverage for distinct land cover classes within 30 m grids from the existing level 3 land cover map. Four schemes with different combinations of input variables were compared. Notably, when all three factors (i.e., mean, std, and fractional cover) were used to consider the variation of landcover in urban areas(Scheme 4, S4), the machine learning model exhibited improved performance compared to using only the mean of optical indices (Scheme 1). Of the various models proposed, the random forest (RF) model with S4 demonstrated the most remarkable performance, achieving R2 of 0.8196, and mean absolute error (MAE) of 0.0749, and a root mean squared error (RMSE) of 0.1022. The std variable exhibited the highest impact on model outputs within the heterogeneous land covers based on the variable importance analysis. This trained RF model with S4 was then applied to the entire Suwon region, consistently delivering robust results with an R2 of 0.8702, MAE of 0.0873, and RMSE of 0.1335. The FTC estimation method developed in this study is expected to offer advantages for application in various regions, providing fundamental data for a better understanding of carbon dynamics in urban ecosystems in the future.

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF