• Title/Summary/Keyword: standard excess rate

Search Result 43, Processing Time 0.024 seconds

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part I : Establishment of Criteria and Verification (고온건강경보시스템 기준 설정에 관한 연구( I ) - 기준 설정 및 검증 -)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.767-780
    • /
    • 2009
  • This study investigates the standard, duration period and excess mortality of extreme heat using the standardized daily mortality data from 1991 to 2004, establishing a standard threshold Criteria for Heat Health Watch Warning System in Korea. It ultimately aims to provide the guidance in building up Heat Health Watch Warning System for Korea by suggesting the standard to quantify thermal stress from heat. The standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city takes into account both daily maximum temperature and daily maximum heat index(HI) and consists of four phases; caution, extreme caution, danger, and extreme danger. Extreme caution phase and danger phase are used as the advisory and warning of extreme heat, respectively. Since the nationwide distribution of the frequency of extreme heat day and the excess mortality rate shows little difference across regions, the standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city can be used for other regions.

Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces (일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

Insurance risk analysis of kidney donors (신장 공여자의 보험의학적 위험분석)

  • Kim, Dong-Jin
    • The Journal of the Korean life insurance medical association
    • /
    • v.29 no.2
    • /
    • pp.18-21
    • /
    • 2010
  • Background: The kidney transplantation is increasing. The kidney donation of a living donor is more common in Korea than in other countries. Underwriters may encounter a case of a kidney donor. So we need to determine medical risk for a living kidney donor. Methods: Comparative mortality figures were calculated from a source article using mortality analysis methods. Results: Mortality Ratio of a living kidney donor was estimated to 106%, and Excess Death Rate was 0.89 per 1000. Discussion: A healthy kidney donor is quite within standard, even better in terms of medical risk.

  • PDF

Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects (식사가 정상인의 맥에 미치는 영향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

Analysis of Consolidation Characteristics of Soft Clay Based on Constant Pressure Ratio Consolidation Test (일정 압력비 압밀시험을 이용한 연약점토의 압밀특성 분석)

  • 김훈규;정두회
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.455-462
    • /
    • 2002
  • There exist several kinds of continuous consolidation tests to analyze the consolidation behavior of soft clay. The constant rate of strain (CRS) test has been adopted as a standard method by several countries, and some researches also have been peformed by domestic researchers. Among those, the constant pressure ratio (CPR) test is peformed with the constant ratio of excess porewater pressure to vertical effective stress. The test has the advantage of considerable reduction of duration time. In the study, the consolidation characteristics are analyzed by performing the CPR test as validate the pressure ratio with undisturbed soft clay and remolded clay, Also, results of the standard consolidation test and CRS test are compared to verify the CPR test can be employed for practical use. As a result, effects of variation of the pressure ratio on consolidation parameter are similar to the strain rate in the CRS test. Therefore, the test can be used to analyze the consolidation behavior of soft clay But the test have some problems such as expensive cost of equipment and highly skilled workmanship.

  • PDF

The Characteristic of Swelling Index Evaluated by CRS Consolidation Test (일정변형속도(CRS) 압밀시험에 의한 팽창지수 산정 특성)

  • 한상재;김수삼;김병일;이응준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.311-317
    • /
    • 2003
  • The swelling index of clayey soil was examined by constant rate of strain(CRS) consolidation test. Four kinds of strain rate were applied during unloading. The strain rates are l/l, l/5, 1/10, l/l 5 of loading. The strain rates during loading are 0.05%/min and 0.03%/min. From the test results using standard consolidometer, the swelling indexes were much similar values in case of 1/5 or 1/10 of the strain rate during loading stage. In the relation between effective stress and excess pore water pressure ratio, it was found that the existence of cross point and the stress level can be separated into two zones according to the swelling index.

Estimating excess post-exercise oxygen consumption using multiple linear regression in healthy Korean adults: a pilot study

  • Jung, Won-Sang;Park, Hun-Young;Kim, Sung-Woo;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.35-41
    • /
    • 2021
  • [Purpose] This pilot study aimed to develop a regression model to estimate the excess post-exercise oxygen consumption (EPOC) of Korean adults using various easy-to-measure dependent variables. [Methods] The EPOC and dependent variables for its estimation (e.g., sex, age, height, weight, body mass index, fat-free mass [FFM], fat mass, % body fat, and heart rate_sum [HR_sum]) were measured in 75 healthy adults (31 males, 44 females). Statistical analysis was performed to develop an EPOC estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and HR_sum were important variables in the EPOC regression models of various exercise types. The explanatory power and standard errors of estimates (SEE) for EPOC of each exercise type were as follows: the continuous exercise (CEx) regression model was 86.3% (R2) and 85.9% (adjusted R2), and the mean SEE was 11.73 kcal, interval exercise (IEx) regression model was 83.1% (R2) and 82.6% (adjusted R2), while the mean SEE was 13.68 kcal, and the accumulation of short-duration exercise (AEx) regression models was 91.3% (R2) and 91.0% (adjusted R2), while the mean SEE was 27.71 kcal. There was no significant difference between the measured EPOC using a metabolic gas analyzer and the predicted EPOC for each exercise type. [Conclusion] This pilot study developed a regression model to estimate EPOC in healthy Korean adults. The regression model was as follows: CEx = -37.128 + 1.003 × (FFM) + 0.016 × (HR_sum), IEx = -49.265 + 1.442 × (FFM) + 0.013 × (HR_sum), and AEx = -100.942 + 2.209 × (FFM) + 0.020 × (HR_sum).

Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection (안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구)

  • Seo, Jae-Ho;Choi, Jin-Yong;Oh, Whan-Sup;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.