• Title/Summary/Keyword: standard amount used

Search Result 757, Processing Time 0.03 seconds

Measurement and Estimation for the Clearance of Radioactive Waste with Patients of Thyroid Treatment (갑상선 진료환자 관련 방사성폐기물의 처분을 위한 방사능 측정 및 평가)

  • Kim, Chang-Bum;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.255-261
    • /
    • 2014
  • The generation amount of radioactive waste has been rapidly increased by increase of the usage of radioisotope source in medical field. Especially, the use of the radioactive source of I-131 with short half-life of 8.02 days used in treatment of thyroid has been increased, and all of the wastes concerned have been disposed by means of the self-disposal method. IAEA proposed criteria for clearance level of waste which depends on the individual (10 ${\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, various radioactive wastes in medical fields are collected and measured for establishing the disposal methods and procedures of radioactive wastes. In addition, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and analytical half-life is considered. With comparing the theoretical half-life and the effective half life(7.72 days) which was based on the decay equation of measured data, it is resulted in the theoretical half-life is longer than effective half-life. The storage period of radioactive waste for self-disposal may be curtailed. The result of this study will be proposed as ISO standard.

Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System (미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성)

  • Lee, Seung-Jin;Ko, Kyeong-Han;Ko, Myeong-Han;Yang, Jae-Kyeong;Kim, Yong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.772-779
    • /
    • 2012
  • For improving performance of conical air diffuser generating fine bubble, both experimental and numerical simulation method were used. After adapting diffusers inner real scale bubble column, suitable for various diffuser submergence, the effect of diffuser submergence on oxygen transfer performance such as Oxygen Transfer Coefficient ($K_{L}a_{20}$) and Standard Oxygen Transfer Efficiency (SOTE) was investigated empirically. As flow patterns for various diffuser number and submergence were revealed throughout hydrodynamic simulation for 2-phase fluid flow of air-water, the cause of the change for oxygen transfer performance was cleared up. As results of experimental performance, $K_{L}a_{20}$ was increased slightly by 7% and SOTE was increased drastically by 39~72%, 5.6% per meter. As results of numerical analysis, air volume fraction, air and water velocity in bioreactor were increased with analogous flow tendency by increasing diffuser number. As diffuser submergence increased, air volume fraction, air and water velocity were decreased slightly. Because circulative co-flow is determinant factor for bubble diffusion and rising velocity, excessive circulation intensity can result to worsen oxygen transfer by shortening bubble retention time and amount.

Study on Improving the Environmental Performance of a Railway Vehicle through a Life Cycle Assessment of the Tilting Train (틸팅열차의 전과정평가를 통한 철도차량 환경성 개선방안연구)

  • Lee, Cheul Kyu;Kim, Yong-Ki;Lee, Jae-Young;Choi, Yo-Han;Kim, Cho-Young
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Recent international environmental regulations are focused on reducing pre-contamination and on sustainable development prior to the usage stage of a product. The Environmental Performance Declaration is being used as a tool for quantifying the environmental performance of products, to reduce contamination in advance, and for advertising the results of railway vehicles in Europe. In this study, a life cycle assessment of the tilting train was conducted, the first such case study in Korea, according to the ISO 14025 standard and Korea EDP (Environmental Declaration of the Product) rule. As a result of the LCA, the life cycle carbon emission of the tilting train was determined to be $3.54{\times}10^7kgCO_2eq.$ which is higher than that of a European train. Also, the amount of $CO_2$ emission of the Mcp and car body is higher than that of the other car and bogie.

A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant (대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구)

  • Shin, Chan-Ki;Shin, Dae-Yun
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.1 s.63
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.

Geophysical and Geochemical Studies for the Saline Water Intrusion under the Paddy Field in Kyoung-gi area, Korea (경기 지역 농경지 하부로의 해수 침투에 관한 지구물리 및 지구화학적 연구)

  • Lee Sang-Ho;Kim Kyoung-Woong;Lee Sang-Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.2
    • /
    • pp.96-103
    • /
    • 1999
  • Most of saline water inousions have been diagnosed by geophysical or geochemical approach independently. The objective of this study is to provide the effective method to detect the saline water intrusion on the ground water in the vicinity of seashore using these two methods. Schulumberger sounding, frequency domain electromagnetic sounding and geochemical analysis of ground water were carried out to explore saline water intrusion. Schulumberger sounding was implemented in dry surface condition before irrigation water was introduced into the field, while electromagnetic sounding was carried out in wet ground condition after the irrigation. The purpose of duplicated measurements on the equivalent spot at different times was to investigate the variation of anomaly zone depending on the amount of ground water. It was possible to discriminate the anomalous zone due to high water saturation from the low electric resistivity zone by high salt concentrations through this way. For the verification of the geophysical result, the ground water samples in the study area were collected and analysed at the 23 points near the measuring spots. The groundwater at the spot nearest to the sea water intrusion identified by geophysical method indicates higher salinity than the standard limit concentration for agricultural irrigation water (250 mg/1). Isotope analysis of $D({^2}H)$ vs. is ${^18}O$ and PCA analysis were used to discriminate the anthropogenic pollution from those of high salinity from sea water intrusion.

  • PDF

The Results of the Survey about Present Situation of Quality Assurance for Radiotherapy Machine of Korea (한국의 방사선치료 기기 품질관리 현황에 관한 설문 결과)

  • Jeong, Seonghoon;Yoon, Myonggeun;Lee, Hyunho
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.185-191
    • /
    • 2015
  • As radiation therapy is one of three major cancer treatment methods, many cancer patients get radiation therapy. Because of the invisible and scattering characteristics of radiation, it is impossible to identify the quality and the amount of radiation and secondary cancer could be induced by scattered radiation. Because of advanced technique of radiation therapy and the reasons mentioned above, quality assurance of radiotherapy machine should be performed completely. International organizations such as International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) suggest report of quality assurance to recommend united method of radiotherapy machine quality assurance. Domestic society of medical physics, however, is too small to make such a report, domestic hospitals selectively choose some of contents in global suggestions. As there are no suggestions for domestic hospitals and global suggestions are being updated, we did a survey about quality assurance for radiotherapy machine. The questionnaire is composed of possession of radiotherapy machine, items performed for quality assurance and manpower, etc. 37 of 72 hospitals answered to survey. These results could be used for making domestic standard quality assurance procedure.

Evaluating Stability and Functionality of Hybrid Erosion Control Dam for Reducing Debris Flow Damage in Forested Catchment Nearby Urban Area (도시생활권의 토석류 피해 저감을 위한 복합형 사방댐의 안정성 및 기능성 평가)

  • Kim, Kidae;Kim, Dongyeob;Seo, Junpyo;Lee, Changwoo;Woo, Choongshik;Kang, Minjeng;Jeong, Sangseom;Lee, Dongkyun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.1
    • /
    • pp.59-70
    • /
    • 2018
  • The objective of this study was to develop erosion control dam for preventing disaster in consideration of characteristics of forested catchment near urban area, and to assess its stability and functionality to see its practicability in the field. Two types of hybrid erosion control dams were developed including debris flow prevention dam by using pillar and float board screen type and debris flow control dam by using groyne. Also, review about their static (sliding, overturning, bearing capacity) and dynamic (member force) stability was carried out. According to the result, most of the assessed items met standard safety level although there were some cases where assessed items were short of stability criteria against impact. Also, after miniature flume experiments based on the developed erosion control dam to prove structure function (material catch, deposit), it turned out the dam decreased flow sediment amount and velocity while increasing sediment-capturing capacity by 3.5 times on average compared to the one controlled without erosion control dam. When function of erosion control dam for forested catchment near urban area is quantified based on future flume experiments in a variety of conditions, the dams can be practically used in the urban area, contribution to effectively reducing debris flow damage.

A noble Sample-and-Hold Circuit using A Micro-Inductor To Improve The Contrast Resolution of X-ray CMOS Image Sensors (X-ray CMOS 영상 센서의 대조 해상도 향상을 위해 Micro-inductor를 적용한 새로운 Sample-and-Hold 회로)

  • Lee, Dae-Hee;Cho, Gyu-Seong;Kang, Dong-Uk;Kim, Myung-Soo;Cho, Min-Sik;Yoo, Hyun-Jun;Kim, Ye-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.7-14
    • /
    • 2012
  • A image quality is limited by a sample-and-hold circuit of the X-ray CMOS image sensor even though simple mos switch or bootstrapped clock circuit are used to get high quality sampled signal. Because distortion of sampled signal is produced by the charge injection from sample-and-hold circuit even using bootstrapped. This paper presents the 3D micro-inductor design methode in the CMOS process. Using this methode, it is possible to increase the ENOB (effective number of bit) through the use of micro-inductor which is calculated and designed in standard CMOS process in this paper. The ENOB is improved 0.7 bit from 17.64 bit to 18.34 bit without any circuit just by optimized inductor value resulting in verified simulation result. Because of this feature, micro-inductor methode suggested in this paper is able to adapt a mamography that is needed high resolution so that it help to decrease patients dose amount.

Effect of sugar content on fermentation characteristics and in vitro digestibility of whole crop wheat silage

  • Song, Tae Hwa;Oh, Young Jin;Park, Jong Ho;Kang, Chon Sik;Cheong, Young Keun;Son, Jea Han;Park, Jong Chul;Kim, Yang Kil;Kim, Kyong Ho;Kim, Bo Kyeong;Park, Tae Il
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.282-282
    • /
    • 2017
  • The many factors such as sugar content, moisture, type of bacteria which predominate, buffering capacity, packing and sealing are known to be associated with silage fermentation quality. Among the sugar content are particularly important, because effective silage ensiling relies on the fermentation of sugar content to lactic acid by lactic acid bacteria. Sugar content is also known to affect the protein utilization of rumen. This study was conducted to observe the effect of water soluble carbohydrates on fermentation characteristics and in vitro digestibility of whole crop wheat silage. This experiment was used standard cultivars (Cheongwoo, Hordeum balgare L) and solid breeding line of whole crop wheat. The materials harvested at the 30 after heading day and chopped for making silage, and using this silage carried out in vitro digestibility for 6, 12, 24 and 48 hours. For the feed value, crude protein, NDF, ADF contents showed slightly higher than the before ensiling and TDN contents were slightly lower compared to the before ensiling, but did not show the significantly different. For the sugar contents, fructose and glucose contents were decreased in the after ensiling compared to the before ensiling, there were more reduced at the containing high sugar content wheat. The pH value was lower at containing high sugar content wheat. lactic acid content was significantly higher at the containing high sugar content wheat. Therefore, there was profitable to the production of high quality wheat silage at the higher the sugar content. In in vitro digestibility test, containing high sugar content HW34line showed significantly higher dry matter digestibility at 6 and 12 hours of incubation and amount of NH3-N lower other line in all incubation time. Therefore, there was profitable to the production of high quality wheat silage at the higher the sugar content.

  • PDF

Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates (백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용)

  • Kim, Choong-Hyon;Woo, Seong Ihl;Jeon, Sung Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.568-575
    • /
    • 1999
  • Two different digestion procedures for the simultaneous determination of major and platinum-group element(PGE) in spent automobile catalysts containing PGE and silicates by inductively coupled plasma atomic emission spectrometry(ICP-AES) are compared. Combinations of mixed aids using HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, and $H_3BO_3$ are utilized for the hot plate dissolution method and the closed-vessel microwave digestion method, The latter method has been shown to be relatively superior in terms of recovery, analysis time, and amount of aqua regia (3 parts HCl + part $HNO_3$ required to dissolve PGE in comparison with conventional open vessel hot-plate dissolution. The best results were drawn from the following conditions: In closed Teflon PFA vessels under microwave heating with temperature/pressure regulation, a 0.25 g portion of sample was digested in 2 mL of HF, 2 mL of $HNO_3$ and 6mL of HCl under the pressure of 200 psi(13.79 bar) at $180^{\circ}C$ for 1hr, followed by a second digestion stage with 16 mL of 5%(w/v) boric acid under the pressure of 20 psi(1.38 bar) at $100^{\circ}C$ for 10 min. After the microwave heating, the sample was post-treated with 10 mL of aqua regia twice by hot-plate heating. This condition gives the PGE recovery within 85~110% and the relative standard deviations within 2%. The method developed can therefore be regarded as an alternative method for routine analysis of spent automobile catalysts.

  • PDF