• Title/Summary/Keyword: standard addition method

Search Result 1,446, Processing Time 0.035 seconds

Assessment for the Comparability between Korean Ministry of Environment Standard and ISO Standard for the Determination of Heavy Metals in Soil (토양 중금속 함량 측정에 대한 토양오염공정시험기준과 국제표준간의 적합성 평가)

  • Shin, Gun-Hwan;Lee, Goon-Teak;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyong;Park, Hyun-Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • According to the agreement on WTO/TBT, we are under the situation to adopt international standard (ISO standard) as a national standard if it exists. However, in case of environmental area, it is a domestic legal obligation to use Korean environmental standard method(KESM) for analyzing various contaminants. Therefore it is necessary to assess the comparability between KEM and ISO standard prior to apply ISO standard to soil conservation law in Korea. The main purpose of this study is to assess the comparability of both methods for analyzing heavy metals in soil. We looked over various aspects like pre-treatment, calibration curve range, detection wavelength, soil organic matter content and so on. Apparently, the procedure of both methods is almost same. However in details, both methods are different in stationary time before aqua-regia extraction using reflux system, calibration curve range for Cu, Pb, Ni and measuring wavelength for Pb. According to the results of comparison test, the results were significantly different when the different calibration range was used. In case that all the extracts independent of methods were reanalyzed with the same calibration range of each method, both methods showed statistically same results. Other conditions like different stationary time, measuring wavelength of AAS and soil organic matter content did not have any influence on the analytical result. Therefore, we suggest to extend the calibration curve range to 0~8 mg/L which is used in KS I ISO standard(Korean standard related with environment which is translation version of ISO standard without any technical change). In case of $Cr^{6+}$, the results showed no significant differences between two methods even though the pretreatment, instrumentation and other analysis conditions were different. In addition to UV/Visble spectrometry of KESM for soil contamination, we suggest to adopt ion chromatography of ISO 15192(US EPA method 7199) for analyzing $Cr^{6+}$ with the consideration of laboratory work efficiency.

Design of Standard Facility Interface for Efficient Building Control (효율적인 빌딩 관제를 위한 표준설비 인터페이스 설계)

  • Moon, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.334-337
    • /
    • 2021
  • Recently, the necessity of rapid response to social problems such as disasters and quarantine arising from the complex and diverse social structures has emerged. As the number of large buildings increases, large-scale human damage is expected in the event of a disaster such as fire. To solve this problem, efficient control must be achieved through interfacing with various equipment and facilities installed inside the building. In this paper, we intend to study the interface method for various facilities in the building for efficient control. In detail, the facility standard model is defined by examining the status and specification of building. In addition, we intend to design and propose a standard facility communication data frame to support the protocol applicable to this model.

Determination of bromine in 1000 ㎍/g Cl standard solution by ID-ICPMS (동위원소희석 질량분석법에 의한 1000 ㎍/g 염소 표준용액 중 브롬 불순물 분석)

  • Park, Chang Joon;Suh, Jung Kee;Song, Hyun Joo;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The isotope dilution method was used for the determination of Br impurity in $1000{\mu}g/g$ Cl standard solution. Since relatively pure KCl salt was used for the preparation of the Cl standard solution, the Br impurity determination suffers from both spectral and non-spectral interferences due to the presence of a large amount of K and Cl matrices. AG2-X8 anion-exchange resin was employed to separate the Br analyte from the matrices, and RF power was raised to 1500 W and nebulizer gas flow rate was lowered to 0.77 L/min to reduce background from the $ArArH^+$ molecular ions. The Br impurity in the $1000{\mu}g/g$ Cl standard solution was determined to be 43.7 ng/g with the standard addition method. The analytical result was in good agreement with 41.2 ng/g (RSD 1.6%) determined by the isotope dilution method to lower uncertainty from poor reproducibility of the anion-exchange process.

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

Semiquantitative Analysis of metal for Cigarette Product by Inductively Coupled Plasma Mass Spectrometry (유도결합 플라스마 질량분석기를 이용한 담배 제품의 무기물 반정량 분석)

  • Cho, Sung-Eel;Kim, Hyo-Keun;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.31 no.2
    • /
    • pp.95-106
    • /
    • 2009
  • Semiquantitative analysis by ICP-MS has proven to be a powerful tool for fast screening, in addition, it does not require the element of interest to be present in the calibration standard, making it especially useful for the analysis of unknown samples. In this study, seven cigarette samples were analyzed by the rapid semi-quantitative analysis method based on the ICP-MS. For each cigarette sample, cut tobacco, cigarette paper, filter (before and after smoking), and smoke condensate were analyzed. The accuracy of the analysis technique was evaluated by comparing results obtained from Calibration Check Standard(CCS) and calibration method. Relative Percentage Error(RPE) value of all elements measured for three CCS showed a stable result of less than ${\pm}20%$. Compared to full quantitative analysis by calibration method, the results for cigarette samples showed average error within ${\pm}15%$.

Uncertainty Analysis of Cross-Correlation Algorithm based on FFT by PIV Standard Images (표준 영상에 의한 FFT 기반 상호상관 PIV 알고리즘의 불확도 해석)

  • Lee, Suk-Jong;Choi, Jung-Geun;Sung, Jae-Young;Hwang, Tae-Gyu;Doh, Deog-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • Uncertainty introduced by a cross-correlation algorithm based on FFT has been investigated using PIV standard images. The standard images were generated by the Monte Carlo simulation method. Both bias and random errors from the velocity vector have been analyzed with regard to the particle diameter, displacement, and the number of particles. The uncertainty of velocity is evaluated based upon the IS0/IEC standard. As a result, a total error of $0.26\%$ is included in the PIV cross-correlation algorithm. In addition, the uncertainty budget is presented, where the effect of the above three variables is examined. According to the budget, the variation of the number of particles within the interrogation window mainly contributes to the combined standard uncertainty of the real measured velocity field when excluding the effect of errors by the experiments itself. Finally, the expanded uncertainty is found to be about $12\%$ at the $95\%$ confidence level.

  • PDF

Review on the New Fire Protection Standard for Nuclear Power Plants and Investigation for the Applicability of the Performance-Based Fire Modeling

  • Jee, Moon-Hak;Hong, Sung-Yull;Sung, Chang-Kyung;Kim, In-Hwang
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.259-267
    • /
    • 2002
  • NFPA-803 has been referred as the Fire Protection Standard at the Nuclear Power Plants of Pressurized Water Reactor. This Standard has been used as the fire protection regulation, containing prescriptive requirements with deterministic methodology. Recently, with cumulative efforts by the U.S. Nuclear Regulatory Commission and Utilities in America to establish a new Standard, including a quantitative evaluation methodology, NFPA-805, the Performance-Based Standard for FIRE Protection for Light Water Reactor Electric Generating Plants was issued and approved by the American National Standards Institute as an American National Standard with an effective date of February 9, 2001. This paper presents an analysis result from the computer modeling for the fire simulation In addition, it proposes the idea that this kind of analytic method can be available for the facilities design of fire prevention and protection fields, as well as an evaluation for the fire suppression system with a quantitative analysis for the thermal phenomena in fire compartments in Nuclear Power Plants.

Flame Spectrophotometric Determination of Sodium in Zirconium Compounds (불꽃 분광광도법에 의한 지르코늄 화합물 중의 나트륨 정량)

  • Choe, Gyu-Won;Yang, Jae-Hyun;Lee, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.2
    • /
    • pp.51-54
    • /
    • 1968
  • Rapid flame spectrophotometric method is developed to determine a small amount of sodium in zircon frit and high purity zirconium compounds. The instrumental characteristics and the optimum conditions are studied and a comparison between calibration curve method and standard addition method is made.

  • PDF

Determination of Selenium in Milk by ICP-OES (ICP-OES를 이용한 우유의 Selenium 분석)

  • 김효중;박종길;신정걸;백영진
    • Food Science of Animal Resources
    • /
    • v.23 no.4
    • /
    • pp.356-360
    • /
    • 2003
  • The purpose of this paper was to determine the quantity of selenium in milk by inductively coupled plasma optical emission spectrometry. The sample was digested in teflon vessel containing nitric-hydrogen peroxide acid mixture. After digestion, the sample is treated with additional hydrochloric acid. Total selenium was reduced with sodium borohydride and concentrated hydrochloric acid in a simplified hydride generation(HG) manifold. The optimum conditions of HG are 2 M for HCl, 1.5% for NaBH$_4$, 1.2 mL/mim for sample flow. Recovery rates by the standard addition method were 88.0% at 10 ppb and 92.2% at 10 ppm. The relative standard deviations were 4.8 and 3.2%, respectively. This method showed a good accuracy and precision. And so it was highly suitable for determination of small quantity of selenium in milk.

A Study on Development of Construction Standard Production Rates and Cost Analysis for Off-Site Construction (OSC)-Based PC Structure Construction Costs - Comparison with RC Method - (OSC기반 PC구조 공사비 산정을 위한 품셈개발 및 공사비 분석 - RC공법과 비교 -)

  • Lee, Hansoo;Lee, Chiho;Han, Heesu;Lee, Jeongwook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.2
    • /
    • pp.56-68
    • /
    • 2024
  • A construction standard production rates system for the factory built and on-site installation phases of OSC (Off-Site Construction)-based precast concrete (PC) structures in apartment buildings was recently proposed to establish an objective cost standard (Lee et al., 2021). In addition, the Korean government has taken steps to improve the institutional foundation for the systematic calculation of PC construction costs such as revising construction standard production rates for major components that can be applied to the on-site installation phase of PC method. In this study, we analyzed the results of a field survey of apartment building PC structures and collected expert opinions to develop factory-built and on-site installation standard production rates that can be applied to apartment building PC method. We also propose directions for improving the standard production rates so that they can be applied to the site and component of apartment buildings by comparing them with the current standard production rates. This study also derived the cost characteristics and cost reduction measures of PC construction by calculating the construction costs using the developed rates and comparing the construction costs with the RC methods of apartment buildings of the same scale. The construction standard production rates for PC construction derived in this study are expected to contribute to the spread of PC construction by ensuring the objectivity and consistency of the results of PC methods cost estimation.