• Title/Summary/Keyword: stainless strip

Search Result 35, Processing Time 0.024 seconds

A study on the bonding properties of YBCO coated conductors with stainless steel stabilizer (스테인레스 강 안정화 YBCO 초전도선재의 접합 특성에 관한 연구)

  • Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Sup;Ko, Rock-Kil;Shin, Hyung-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.262-263
    • /
    • 2005
  • For mechanical and electrical stability and environment protection, Cu and stainless steel stabilizer is laminated to Ag layer to produce a composite neutral-axis(N-A) architecture in which the YBCO layer is centered between the oxide buffered metallic substrate and stabilizer strip lamination. this architecture allows the wire to meet operational requirements including stresses at cryogenic temperature, winding tensions, mechanical bending requirements thermal and electrical stability under fault conditions. we have experimentally studied mechanical properties of laminated stainless steel stabilizer on YBCO coated conductors. we have laminated YBCO coated conductors by continuous dipping soldering process. we have investigated lamination interface between solder and stabilizer, YBCO coated conductor. we evaluated bonding properties tensile / shear bonding strength, peeling strength laminated YBCO coated conductors.

  • PDF

Three Dimensional Analysis of Primary Maxillary Central and Lateral Anterior Zirconia Crown (상악 유절치 지르코니아 전장관 수복을 위한 3차원 분석)

  • Lee, Jungmin;Lee, Hyoseol;Nam, Okhyung;Kim, Misun;Choi, Sungchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.2
    • /
    • pp.176-186
    • /
    • 2016
  • This study was performed to compare the shape and dimension of anterior zirconia crowns to other pediatric crowns using a three-dimensional scanner to investigate adequate amount of tooth preparation. Primary central and lateral anterior zirconia crowns, stainless steel crowns and celluloid strip crowns were scanned by a three-dimensional scanner. Outer and inner surfaces of zirconia and stainless steel crowns, and outer surface of celluloid strip crowns were analyzed. In outer scanned images, all sizes of central and lateral size 1 zirconia crown had the largest labiolingual diameter among the three crowns. In inner scanned images, zirconia crown's mesiodistal diameter was 0.7-1.0 mm smaller and crown length was approximately 1 mm shorter than those of stainless steel crowns. Zirconia crown's labiolingual diameter was larger in central crowns whereas it was smaller in lateral crowns than that of stainless steel crowns. Recommended preparation required for zirconia crown is incisal 2.5-3.0 mm, mesiodistal 1.5-2.0 mm, labial 0.5-1.0 mm. Cingulum should be trimmed parallel to the long axis. No more lingual reduction is needed in central incisors whereas additional 0.5 mm reduction is suggested in lateral incisors.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

A Study on the Erosion Behavior of the Ceramic Sprayed Coating Layer in the Molten 55% Al-Zn (용융 55%Al-Zn 중에서 세라믹 용사 피막의 침식 거동에 관한 연구)

  • 강태영;임병문;최장현;김영식
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2000
  • Sink roll has been used in molten 55%Al-Zn alloy bath of continuous galvanizing line for sinking and stabilizing working steel strip in molten metal bath. In the process, the sink roll body inevitably build up dross compounds and pitting on the sink roll surface during 55%Al-Zn alloy coated strip production, and the life time of the sink roll is shorten by build up dross compounds and pitting. The present study examined the application of thermally sprayed ceramic coatings method on sink roll body for improving erosion resistance at molten 55% Al-Zn pool. In this experiment, the stainless steels such as STS 316L and STS 430F were used as the substrate materials. The CoNiCr and WE-Co powder were selected as bond coating materials. Moreover $Al_2O_3-ZrO_2-SiO_2 and ZrO_2-SiO_2$ powders selected as the top coating materials. Appearances of the specimens before and after dipping to molten 55%Al-Zn pool were compared and analyzed. As a result of this study, STS430F of substrate, WC-Co of bond spray coatings, $ZrO_2-SiO_2$ power of top spray coatings is the best quality in erosion resistance test at molten 55%Al-Zn pool

  • PDF

A study on the bonding properties of YBCO coated conductors with stabilizer tape (안정화 선재의 YBCO 초전도 접합 특성)

  • Kim Tae-Hyung;Oh Sang-Soo;Ha Dong-Woo;Kim Ho-Sup;Ko Rock-Kil;Shin Hyung-Seop;Park Kyung-Chae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.23-26
    • /
    • 2006
  • For mechanical and electrical stability and environment protection. Cu and stainless steel stabilizers are laminated to a Ag layer to produce a composite neutral-axis(N-A) architecture in which the YBCO layer is centered between the oxide buffered metallic substrate and stabilizer strip lamination. This architecture allows the wire to meet operational requirements including stresses at cryogenic temperature. winding tensions as well as mechanical bending requirements including thermal and electrical stability under fault current conditions. We have experimentally studied mechanical properties of the laminated stainless steel and Cu stabilizers on YBCO coated conductors. We have laminated YBCO coated conductors by continuous dipping soldering process. We have investigated lamination interface between solder and stabilizer of the YBCO coated conductor. We evaluated bonding properties. tensile / shear bonding strength. and peeling strength laminated YBCO coated conductors.

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Experimental Study of a Recuperator with Offset Strip Fins (오프셋 스트립 휜을 가지는 리큐퍼레이터에 대한 실험적 연구)

  • Kim, Taehoon;Do, Kyu Hyung;Han, Yong-Shik;Choi, Byung-Il;Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.72-78
    • /
    • 2015
  • In the present study, a recuperator to improve the thermal efficiency of a micro gas turbine is considered. The counter flow plate-fin heat exchanger with offset strip fins is chosen as the type of the recuperator. From the optimization study as varying design parameters of the recuperator determined from the ideal cycle analysis, the internal structure of the recuperator is determined. The recuperator is made from stainless steel 304. In order to evaluate performance of the recuperator, experimental investigation is performed. The effects of inlet temperature of hot-side of the recuperator on the thermal performance of the recuperator are investigated. As a result, effectiveness of the recuperator obtained from the experiments is well consistent with that obtained from the correlations.

Fabrication of Bending Actuator for Micro Active Catheter (초소형 작동형 내시경용 Bending 액츄에이터의 제작)

  • Lee, Kwang-Ho;Lee, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.615-617
    • /
    • 1997
  • This paper reports experimental results on the fabrication and analysis of millimeter-sized bending actuators for active catheter by use of the shape memory alloy spring and the flexible beam. The major components of micro actuator are shape memory alloy spring, stainless steel strip and two acryl links. The micro actuator with the diameter of 2.0 mm and the length of 25 mm has been fabricated and characterized for the possible application to the micro active catheters. The measured maximum angle is $60^{\circ}$ and the response time is 5 sec.

  • PDF

Studies on a Feasibility of Swine Farm Wastewater Treatment using Microbial Fuel Cell (미생물연료전지의 가축분뇨 처리 가능성 연구)

  • Jang, Jae-Kyung;Kim, Se-Hee;Ryou, Young-Sun;Lee, Sung-Hyoun;Kim, Jong-Gu;Kang, Young-Goo;Kim, Young-Hwa;Choi, Jung-Eun
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.461-466
    • /
    • 2010
  • In this study the feasibility of simultaneous electricity generation and treatment of swine farm wastewater using microbial fuel cells (MFCs) was examined. Two single-chamber MFCs containing an anode filled with different ratio of graphite felt and stainless-steel cross strip was used in all tests. The proportion of stainless-steel cross strip to graphite felt in the anode of control microbial fuel cell (CMFC) was higher than that of swine microbial fuel cell (SMFC) to reduce construction costs. SMFCs produced a stable current of 18 mA by swine wastewater with chemical oxygen demand (COD) of $3.167{\pm}80\;mg/L$ after enriched. The maximum power density and current density of SMFCs were $680\;mW/m^3$ and $3,770\;mA/m^3$, respectively. In the CMFC, power density and current density was lower than that of SMFC. CODs decreased by the SMFC and CMFC from $3.167{\pm}80$ to $865{\pm}21$ and $930{\pm}14\;mg/L$, achieving 72.7% and 70.6% COD removal, respectively. The suspended solid (SS) of both fuel cells was also reduced over 99% ($4,533{\pm}67$ to $24.0{\pm}6.0\;mg/L$). The concentration of nutritive salts, ${NH_4}^+$, ${NO_3}^-$, and ${PO_4}^{3-}$, dropped by 65.4%, 57.5%, and 73.7% by the SMFC, respectively. These results were similar with those of CMFC. These results show that the microbial fuel cells using electrode with mix stainless-steel cross strip and graphite felt can treat the swine wastewater simultaneously with an electricity generation from swine wastewater.

ESTHETIC RESTORATION OF ANTERIOR STAINLESS STEEL CROWN WITH COMPOSITE RESIN VENEER (Stainless steel crown 순면위에 레진피복을 이용한 전치부 심미적 수복)

  • Park, Jong-Ha;An, Soo-Hyeon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.805-812
    • /
    • 1997
  • Despite dentistry's attempts to improve the dental health of the public and to minimize the effects of caries, many children still present with extensive destruction of primary anterior teeth. One of dentistry's most challenging tasks is to repair these teeth with restoration which are durable, retentive, and esthetic. Esthetic restoration can often be achieved with polycarbonate crowns, strip crowns, conventional S-S crowns, open-faced S-S crowns, commercially veneered S-S crowns. But, all of these have limitation. Advances in restorative materials and metal-bonding procedures have made possible new restorative techniques that combine the advantages of S-S crowns with the cosmetics of composite restoration methods. The described technique of bonding composite to trimmed and fitted S-S crowns offers many advantages over other techniques currently used to restore primary anterior teeth. 1. If S-S crowns are accurate trimmed and contoured, good retention of crowns is achieved. 2. The patient time required is similar to that of conventional S-S crowns. 3. Good esthetics and high bond strengths are achieved. 4. It is possible to use this veneering technique intraorally on crowns that have fractured veneers.

  • PDF