• Title/Summary/Keyword: stainless pipe

Search Result 190, Processing Time 0.028 seconds

Safety Evalution of on the cable of Extra dosed bridges by fire (화재에 대한 Extra-dosed교 케이블의 안전성 평가)

  • Rhu, Bong-Jo;Song, Young-Sun;Park, Weon-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.23-33
    • /
    • 2008
  • Extra dosed bridge among the Cabled-stayed bridges have been increasingly built in korea in recently. But such bridges were often damaged by fire due to car collison. In this study Extra dosed bridges among the cabled-supported bridges are selected to analysis model frequently to be designed and/or constructed in recent and furture in this study. COSMOS FloWorks 2007 software are used for Heat Transfer Analysis and Thermal Stress Analysis. The safety of wire, HDPE pipe and stainless steel pipe are investigated. In the case of the constant of the temperature of the heat source, the significant three variables for the analysis are selected for study : (1) the distance between the fire-proof bulk head and the heat source, (2) wind velocity, (3) the height of the end of Stainless steel pipe.

A Study on MsS Guided Wave Scattering from Defects (MsS Guided Wave를 이용한 결함 신호의 분석에 관한 연구)

  • Choi, Boo-Il;Cho, Youn-Ho;Lee, Joon-Hyun;Shin, Dong-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2009
  • An investigation has been made on the relationship between characteristics of torsional mode signal in MsS and SH mode signal in BEM modeling for the defect of stainless steel pipe. In order to compare torsional mode signal with SH mode signal of defect in stainless steel pipe, specimens were made by changing size of depth and width along to circumferential direction 360 degrees. All the defects was detected by torsional mode signal of MsS, especially according to the change of depth size, amplitude of signal was changed. But width change for the circumferential defects has no certain tendency. SH mode signal of BEM modeling shows similar results with torsional mode, with change makes amplitude variation of signal. In this paper, the characteristics of torsional mode and SH mode signals were found. It is possible to predict the circumferential defects for the pipe by SH mode modeling.

Crack growth analysis and remaining life prediction of dissimilar metal pipe weld joint with circumferential crack under cyclic loading

  • Murthy, A. Ramachandra;Gandhi, P.;Vishnuvardhan, S.;Sudharshan, G.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2949-2957
    • /
    • 2020
  • Fatigue crack growth model has been developed for dissimilar metal weld joints of a piping component under cyclic loading, where in the crack is located at the center of the weld in the circumferential direction. The fracture parameter, Stress Intensity Factor (SIF) has been computed by using principle of superposition as KH + KM. KH is evaluated by assuming that, the complete specimen is made of the material containing the notch location. In second stage, the stress field ahead of the crack tip, accounting for the strength mismatch, the applied load and geometry has been characterized to evaluate SIF (KM). For each incremental crack depth, stress field ahead of the crack tip has been quantified by using J-integral (elastic), mismatch ratio, plastic interaction factor and stress parallel to the crack surface. The associated constants for evaluation of KM have been computed by using the quantified stress field with respect to the distance from the crack tip. Net SIF (KH + KM) computed, has been used for the crack growth analysis and remaining life prediction by Paris crack growth model. To validate the model, SIF and remaining life has been predicted for a pipe made up of (i) SA312 Type 304LN austenitic stainless steel and SA508 Gr. 3 Cl. 1. Low alloy carbon steel (ii) welded SA312 Type 304LN austenitic stainless-steel pipe. From the studies, it is observed that the model could predict the remaining life of DMWJ piping components with a maximum difference of 15% compared to experimental observations.

Construction Method and Control System of the Heat of Hydration for Inchon International Airport Elevated Road Way (인천국제공항 여객터미널 전면 고가 교량 공사 시공방법 및 수화열 대책)

  • 임채만;박명웅;조용기;조선규;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.869-881
    • /
    • 1999
  • Inchon International Airport Elevated Road Way is located between the Passenger Terminal Building and Transportaion Center which are Inchon International Airport core construction projects. The deck of the bridge is consists of 5-span or 6-span continuous pre-stressed concrete slab. Steel form has been used to enhance the quality of texture on concrete slab. Steel form has been used to enhance the quality of texture on concrete surface, lower surface of deck slab with the two way arch has been manufactured by highly professional manner in order to get an beautiful exterior architectural looks. The prestressed concrete deck slab is mass concrete structures with a high-specified concrete strength and a varying section in the range of 0.95-2.8m thickness. Therefore high risks of thermal cracking occurrence by heat of hydration highly are expected. To resolve such problem, we adopted type 1 cement and pipe cooking method at construction site through mass concrete specimen test and 3-dimensional analysis. For Pipe cooling we used 25mm diameter stainless pipes with wrinkles. Cooling pipe with spacing 50-60cm has been installed. And continuous pipe cooling with cooling water of 15$^{\circ}C$ was conducted for 2days. In present 8 span of all 29 spans construction has been completed. No thermal cracking heat hydration has been observed yet.

  • PDF

A Study on the Drag Reduction Effect and Heat Transfer Enhancement of Non ionized Surfactant and Water Mixture in a Circular Pipe Flow (비이온계 계면활성제 첨가수에 대한 관내 유동저항 감소 및 열전달 촉진에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2007
  • This paper has dealt with the effect of non ionized surfactant and water mixture on drag reduction and heat transfer enhancement in a circular pipe flow with experimentally. The test section was consisted of stainless steel pipe with inside diameter of 16mm. The wire coil was used to increase heat transfer in a pipe and the on ionized surfactant(Oleyl Dihydroxyethyl Amino Oxide, ODEAO) was used to reduce the drag force of water mixture with surfactant. The main parameters of this experiment were diameter and pitch of wire coil and the ratio of test section length and horizontal wire coil length. In this experiment, the acquired results were 1) Drag reduction effect existed in this ODEAO-water mixture, 2) Friction factor and heat transfer were increased with insertion the heat transfer enhancement coil, 3) With increasing of pitch ratio, heat transfer was decreased, and 4) Heat transfer was decreased by the decreasing of inserting coil diameter.

Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse (탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과)

  • Paek, Y.;Jeon, J.G.;Yun, N.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

Multiple Regression Analysis for Piercing Punch Profile Optimization to Prevent Tearing During Tee Pipe Burring (다중 회귀 분석을 활용한 Tee-Pipe 버링 공정에서 찢어짐 방지를 위한 피어싱 펀치 형상 최적 설계)

  • Lee, Y.S.;Kim, J.Y.;Kang, J.S.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.271-276
    • /
    • 2017
  • A tee is the most common pipefitting used to combine or divide fluid flow. Tees can connect pipes of different diameters or change the direction of a pipe run. To manufacture tee type of stainless steel pipe, combinations of punch piercing and burr forming have been widely used in the industry. However, such method is considerably time consuming with regard to performing empirical work necessary to attain process conditions to prevent upper end tearing of the tee product and meet target tee height. Numerous experiments have shown that the piercing profile is the main cause of defects mentioned above. Furthermore, the mold design is formed through trial and error according to pipe diameters and changes in requirements. Thus, the objective of this study was to perform piercing and burring process analysis via finite element analysis using DYNAFORM to resolve problems mentioned above. An optimization design method was used to determine the piercing punch profile. Three radii of the piercing punch (i.e., large, small, and joined radii) were selected as design variables to minimize thinning of a tee pipe. Based on results of correlation and multiple regression analyses, we developed a predictive approximation model to satisfy requirements for both thickness reduction and target height. The new piercing punch profile was then applied to actual tee forming using the developed prediction equation. Model results were found to be in good agreement with experimental results.

Effect of Loading Rate on the Deformation Behavior of SA508 Gr.1a Low Alloy Steel and TP316 Stainless Steel Pipe Materials at RT and 316℃ (상온과 316℃에서 SA508 Gr.1a 저합금강 배관과 TP316 스테인리스강 배관의 변형거동에 미치는 하중속도의 영향)

  • Kim, Jin Weon;Choi, Myung Rak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.383-390
    • /
    • 2015
  • This study conducted tensile tests on SA508 Gr.1a low alloy steel and SA312 TP316 stainless steel piping materials under various strain rates at room temperature (RT) and $316^{\circ}C$ to investigate the effects of loading rate on the deformation behavior of nuclear piping materials. At RT, the deformation behavior for both pipe materials showed a typical loading rate dependence, i.e., the strength increased and the ductility decreased as the loading rate increased. At $316^{\circ}C$, however, the strength and elongation of SA508 Gr.1a low alloy steel decreased as the loading rate increased, and its reduction of area non-linearly varied with the loading rate. For SA312 TP316 stainless steel, the strength, elongation, and reduction of area at $316^{\circ}C$ were almost the same regardless of the loading rate. At both temperatures, the strain hardening capacity was nearly independent of the loading rate for SA508 Gr.1a low alloy steel, while it decreased with increasing loading rate for SA312 TP316 stainless steel.

Research of detect of the object in stainless pipe using the magnetic inductance (자기인덕턴스를 이용한 Stainless Steel 배관 내 이물질 검사에 대한 연구)

  • Joo, Gun-June;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.179-181
    • /
    • 2006
  • 각 원자력 발전소에서는 정밀성, 안전성을 확인하는 검사의 중요성을 인식하여 LPMS(Loose Part Monitoring System)을 사용하여 사고 징후를 조기에 감지하여 이에 대한 예방조치를 가능케 함으로써 설계기준 사고 발생을 사전에 방지할 수 있게 한다. 또한 이 기술은 신호 측정 및 분석 등의 기반기술 개발을 통하여 건전성 감시 기술의 신뢰성을 향상 시키고 있다. LPMS(Loose Part Monitoring System)기술은 재료, 기기, 구조물 등의 성질과 내부조직을 변화시키거나 파괴하지 않고, 배관내부에 흐르는 금속 파편들을 찾아내어 정밀성, 안전성, 신뢰성을 확보하기 위하여 검사기술이 적용되고 있다. 그러나 이 방법은 배관내의 이물질의 충격이 발생해야 감지가 가능하고, 이물질의 모양이나 사이즈를 확인하기에는 어려움이 있다. 따라서 본 논문에서는 배관외부에서 자기장을 인가하여, 배관내의 이물질에 변화하는 자기장을 홀센서로 측정하여 기존의 LPMS 방식을 보완하는 시스템을 개발하기 위해, 배관에 필요한 자기장 발생장치를 설계하고, 이물질을 검출하기 위한 검출 감도향상에 대해 연구하였다.

  • PDF

Fluid Heating System using High-Frequency Inverter Based on Electromagnetic Indirect Induction Heating

  • Kim Yong-Ju;Shin Dae Cheul;Kim Kee Hwan;Uchihori Y.;Kawamura Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.69-74
    • /
    • 2001
  • In this Paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF