• 제목/요약/키워드: stainless 304 2B

검색결과 34건 처리시간 0.024초

레이저피닝을 이용한 스테인리스강의 표면 경도 강화 (Enhancement of Surface Hardness of Stainless Steel by Laser Peening)

  • 임현택;이명화;김필규;박종복;정성호
    • 한국레이저가공학회지
    • /
    • 제12권3호
    • /
    • pp.18-22
    • /
    • 2009
  • Experimental results for the laser shock peening of stainless steels, duplex stainless steel and STS304, for the enhancement of surface hardness are reported. A high power Nd:YAG laser (532 nm, 2nd harmonics) was used to irradiate the workpiece in water at the irradiances of 5, 10, $15\;GW/cm^2$. The surface of a workpiece was covered with Fe or Al foil for protection of the original surface and reduction of laser reflection. The laser pulse densities were varied from $25\;pulse/mm^2$ to $75\;pulse/mm^2$. In the case of the STS304, the surface hardness increased with increasing pulse density and the maximum increase of about 29% was achieved using Fe foil at $10\;GW/cm^2$ and $75\;pulse/mm^2$ conditions. The maximum increase in surface hardness of duplex stainless steel was about 8% at $10\;GW/cm^2$ and $75\;pulse/mm^2$ with also Fe foil. In the case of the Al foil, less increase of surface hardness was obtained, possibly due to the thermal expansion effect.

  • PDF

정전위 전해에칭법에 의한 스테인레스 강의 입계 석출물 분석 (Analysis of the grain boundary precipitates in stainless steel by potentiostatic etching dissolution method)

  • 박신화;안병량;홍기정;이도형
    • 분석과학
    • /
    • 제6권2호
    • /
    • pp.157-165
    • /
    • 1993
  • 강 중 석출물을 추출분리한 후 이를 정량분석하는 것을 목적으로 개발된 정전위 전해법을 304 스테인레스 판재 및 선재 제조시에 발생한 결함 원인 분석에 활용하여 시료의 조직을 관찰하였으며, 결함 원인을 조사하였다. 스테인레스 선재 및 판재의 균열 전파 양상은 정전위 전해법을 이용하여 에칭한 후 주사전자현미경으로 관찰하였고, 입계를 따라서 존재하는 조대한 석출물은 EDS 및 EPMA를 이용하여 성분분석을 행하였다. 이들 조대한 석출물의 구조분석은 X-선 회절 패턴을 이용하여 행하였다. 판재 및 선재 두 경우 모두 균열은 입계를 따라서 전파하고 있었으며, 입계에는 $M_{23}(C,\;B)_6$ 이외에 조대한 $M_2C$ 석출물이 존재하는 것으로 확인되었다. 이들 석출물들의 분석에 정전위 전해에칭법을 이용함으로써 양호한 시료를 얻을 수 있었다.

  • PDF

반복과대하중에 의한 피로파괴거동의 고찰 (An evaluation of Fatigue Crack Propagation Behaviors on Cyclic Overload Test)

  • 김용수;신근하;강동명;김병석
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.47-56
    • /
    • 1992
  • The retardation effect of fatigue crack propagation after cyclic overloading seems to be affected by strain hardening exponent. Namely, for the material with high values of n, the delay effect is found to be severe. We proposed a modified crack retardation equation which may apply the retardation of fatigue crack growth after a cyclic overloading, as (da/dN)'$_{cyc}$=($\mu$n+λ)B $\Delta$ $K^{q}$ /[(1- $R_{eff}$) $K_{cf}$$\Delta$K]. where, $R_{eff}$ is effective stress ratio [=( $K_{min}$-K, os)/( $K_{max}$$K_{res}$)] The constants $\mu$=-0.5 and λ=0.6, and the values are found to be identical for materials such as aluminum (A 1060), steel (SS 34), brass ( $B_{s}$ SIB) and stainless steel (SUS 304) used in this investigation. (SUS 304) used in this investigation.ation.n.n.

  • PDF

8인치 직경의 304L 스테인리스강관의 부식특성에 미치는 제작공정의 영향 (Effect of Manufacturing Process on the Corrosion Properties of 304L Stainless Steel Pipe with 8-inch Diameter)

  • 김기태;허승영;장현영;김영식
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.279-286
    • /
    • 2018
  • Austenitic stainless steels used in nuclear power plants mainly use pipes made of seamless pipes, which depend on imports. The manufacturing process and high cost are some of the problems associated with seamless pipes. Therefore, in this study, the corrosion characteristics of the seamless pipe and the SAW pipe were assessed to determine the safety and reliability of the SAW pipe in a bid to replace the seamless pipe. Microstructure was analyzed using an optical microscope and the degree of hardness was measured using a Rockwell B scale. Intergranular corrosion resistance was evaluated by ASTM A262 Practice A, C, and E methods. The degree of sensitization was determined using a DL-EPR test. Anodic polarization test was performed in deaerated 1% NaCl solution at $30^{\circ}C$ and the U-bend method was used to evaluate the SCC resistance in 0.01 M $Na_2S_4O_6$ at $340^{\circ}C$ and 40% NaOH solution at $290^{\circ}C$. Weld metal of the SAW pipe specimen showed relatively high degree of sensitization and intergranular corrosion rate. However, annealing to SAW pipes improved the corrosion properties in comparison to that of the seamless pipe.

Stainless Steel Surface Oxidized in Strong Oxidizing Solution

  • Kyoung-Chul Lee;Kyoung-Hee Ham;Woon-Sun Ahn
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권5호
    • /
    • pp.520-524
    • /
    • 1991
  • Stainless steel 304 2B and BA are oxidized in 2.5 M $CrO_3/$ 5.0 M $H_2SO_4$ solution, and elemental composition and oxidized state of the surface region is analyzed as a function of the surface depth using X-ray photoelectron spectroscopy. It is found that Fe and Cr are preferentially oxidized and diffuse outward following the oxidation. Element Ni, the third major component of the steel is not oxidized and remains deep under the surface. It is also found that the oxidized Fe dissolves considerably into the solution thereby enriching the gas-oxide interface with Cr.

軟鋼의 高溫 表面渡勞균열 成長擧動에 관한 硏究 (A Study on Propagation Behavior of Surface-Fatigue-Crack in the Mild Steel at Elevated Temperatures)

  • 김규남;서창민;;강성수
    • 대한기계학회논문집
    • /
    • 제7권4호
    • /
    • pp.425-433
    • /
    • 1983
  • Fatigue tests by axial loading (R=0.1) were carried out to investigate fatigue crack growth properties of small surface cracks in mild steel at room temperature, 250.deg. C and 400.deg. C, by using flat specimens with a small artificial pit. All the data of the fatigue crack growth rate obtained in the present tests are determined as a function of the stress intensity factor range, so that the applicability of liner fracture mechanics to the fatigue crack growth of surface cracks at elevated temperatures is investigated and discussed in comparison with the data of type 304 stainless steel at room temperature and elevated temperature. The obtained results are as follows: 1) Relations of both surface fatigue crack length and its depth to cycle ratio fall within a narrow scatter band in spite of different stress levels. 2) The .DELTA. .sigma. .root. .pi. a-da/dN relation of surface fatigue crack growth at room temperature is independent of the stress level and can be plotted as a straight line at log-log diagram, but the relation at 400.deg. C depends partly on the stress level. 3) Relations of the fatigue crack growth into depth d(2b)/dN and is stress intensity factor range .DELTA. $K_{I}$, accounted for the aspect ratio variation, fall within a narrow scatter band for wide range of the applied stress levels. And .DELTA. $K_{I}$E-d(2b)/dN relations of mild steel at different stress level coincide relatively well with the data of type 304 stainless steel. 4) The value of aspect ratio obtained by a beach mark method and a temper coloring method approaches about 0.9 in common with crack growth and it is independent of stress level and temperatures. 5) The equi-crack length curve is parallel to S-N$_{f}$ curve at elevated temperatures.s.s.s.

가로등주 소재 적용을 위한 200계 스테인리스강의 용접부 특성 연구 (A Study on the Welds Characteristics of 200 Grade Stainless Steel for Application of Street Pole Material)

  • 이병우;이도경;김현수;홍성현
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.33-39
    • /
    • 2009
  • The aim of this study is to analyze the welds characteristics of the 205 stainless steel pipe for application of street pole material. The welds corrosion behavior of STS 205 pipe in 0.1 N sulphuric acid solution and 5% NaCl solution at room temperature was studied using both salt spray test and potentiodynamic polarization experiment. The morphology and components of corrosion products on surface of STS 205 pipe welds were investigated using SEM/EDX. The tensile strength and yield strength values of STS 205 plate were 715 MPa and 369 MPa respectively. The microvickers hardness values of STS 205 pipe welds were slightly increased than that of STS 304 pipe welds. Corrosion current density($I_{corr.}$) and critical current density($I_{crit.}$) values of STS 205 pipe welds in 3.5% NaCl solution were $1.89{\times}10^{-6}$ $A/cm^2$ and $15.8{\times}10 ^{-6}$ $A/cm^2$. The corrosion resistance of SIS 205 pipe welds was similar to its STS 304 pipe welds. The STS 205 and 304 pipe welds passive films were chromium oxide. Especially, the STS 205 pipe welds showed good corrosion resistance in 0.1 N sulphuric acid. This is attributed to the forming of protective chromium oxide on the surface of STS 205 pipe welds.

  • PDF

초음파탐상 수행시 Polarity Thresholding 알고리즘을 이용한 재료잡음 억제 (Material Noise Reduction in Ultrasonic Test Using Polarity Thresholding Algorithm)

  • 구길모;고대식;김태현;전계석
    • 한국음향학회지
    • /
    • 제14권1호
    • /
    • pp.73-80
    • /
    • 1995
  • 본 논문에서는 Polarity Thresholding(PT) 알고리즘을 원자력 발전소의 중요 배관 재료인 스테인레스강(SUS-304) 탐상에 응용하여 초음파 수신신호를 개선시키는 방법을 연구하였다. PT 알고리즘은 수신신호의 스펙트럼을 분할하여 얻은 각각의 주파수분할 신호들이 갖는, 결정립에 의한 간섭패턴의 분산적 신호와 결함에 의한 비분산적 신호를 구분하여 S/N 비를 개선시키는 것이다. 실험을 위하여, 실제 검사부위의 특성과 유사하게 스테인레스강을 각각 1125, 1150, 1175, $1200^\circ{C}$로 열처리하였고, 시료의 배면에 원통형 결함을 인공 가공하였다. 중심주파수가 5MHz인 초음파변환기를 사용하여, 펄스-반사법에 의해 데이터를 획득한 후 PT 알고리즘을 적용한 결과 개선된 S/N 비는 평균 14.2 dB로 나타났다.

  • PDF

Hardness and Corrosion Resistance of Surface Composites Fabricated with Fe-based Metamorphic Powders by High-energy Electron Beam Irradiation

  • Nam, Dukhyun;Lee, Kyuhong;Lee, Sunghak;Young, Kyoo
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.301-306
    • /
    • 2008
  • Surface composite layers of 1.9~2.9 mm in thickness were fabricated by depositing metamorphic powders on a carbon steel substrate and by irradiating with a high-energy electron beam. In the surface composite layers, 48~64 vol.% of $Cr_{2}B$ or $Cr_{1.65}Fe_{0.35}B_{0.96}$ borides were densely precipitated in the austenite or martensite matrix. These hard borides improved the hardness of the surface composite layer. According to the otentiodynamic polarization test results of the surface composites, coatings, STS304 stainless steel, and carbon steel substrate, the corrosion potential of the surface composite fabricated with 'C+' powders was highest, and its corrosion current density was lowest, while its pitting potential was similar to that of the STS304 steel. This indicated that the overall corrosion resistance of the surface composite fabricated with 'C+' powders was the best among the tested materials. Austenite and martensite phases of the surface composites and coatings was selectively corroded, while borides were retained inside pits. In the coating fabricated with 'C+' powders, the localized corrosion additionally occurred along splat boundaries, and thus the corrosion resistance of the coating was worse than that of the surface composite.

Study on High-Temperature Oxidation Behaviors of Plasma-Sprayed TiB2-Co Composite Coatings

  • Fadavi, Milad;Baboukani, Amin Rabiei;Edris, Hossein;Salehi, Mahdi
    • 한국세라믹학회지
    • /
    • 제55권2호
    • /
    • pp.178-184
    • /
    • 2018
  • In the present study, $TiB_2-Co$ composite coatings were thermally sprayed onto the surface of a 304 stainless steel substrate using an atmospheric plasma spray (APS). The phase analysis of the powders and plasma-sprayed coatings was performed using X-ray diffractometry analysis. The microstructures of the coatings were studied by a scanning electron microscope (SEM). The average particle size and flowability of the feedstocks were also measured. Both $TiB_2-32Co$ and $TiB_2-45Co$ (wt.%) coatings possessed typical dense lamellar structures and high-quality adhesion to the substrate. The oxidation behaviors of the coatings were studied at $900^{\circ}C$ in an atmospheric environment. In addition, the cross-sectional images of the oxidized coatings were analyzed by SEM. A thin and well-adhered layer was formed on the surface of both $TiB_2-Co$ coatings, confirming satisfactory high-temperature oxidation resistance. The kinetic curves corresponding to the isothermal oxidation of the coatings illustrated a short transient stage from rapid to slow oxidation during the early portion of the oxidation experiment.