• Title/Summary/Keyword: stack simulation

Search Result 240, Processing Time 0.023 seconds

The Simulation of PEMFC System Performance for Automotive Application (1) (작동조건을 고려한 자동차용 PEM 연료전지 시스템 성능 시뮬레이션 (1))

  • Bang, Jung-Hwan;Kim, Han-Sang;Lee, Dong-Hun;Min, Kyoung-Doug;Kim, Min-Soo;Cho, Young-Man
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.460-465
    • /
    • 2003
  • The modeling of PEM (Proton Exchange Membrane) fuel cell system consisting of fuel cell stack and BOP (Balance of Plant) is presented in this paper. The effects of temperature, pressure (air, hydrogen), and humidity on the fuel cell system performance were mainly investigated using thermo-dynamical and electro-chemical equations. To understand the power distribution characteristics of fuel cell system, the effects of operating temperature and air pressure on maximum power and system power were also demonstrated. Through this study, we can get the basic insight into the fuel cell stack and BOP component sizing and it can be used effectively for the optimization of the practical fuel cell systems in purpose.

  • PDF

Influences of Coatings and Solution Corrosivity on Cathodic Protection of Metallic Materials

  • Yoo, Y.R.;Chang, H.Y.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.106-111
    • /
    • 2006
  • Painting has protected metallic stack but the paint films may be degraded and corrosion problem can be arisen. To protect the painted metal stack, cathodic protection can be applied. If cathodic protection is applied to bare metal, only small area may be protected. However, if cathodic protection is applied to painted metal surface, large area can be protected and the lifetime of paint films can be extended. High corrosion resistant alloys were corroded at a Flue Gas Desulfurization (FGD) facility of power plant within a short period and thus cathodic protection can be used to protect these metals. On the base of computer simulation, if cathodic protection is applied to bare metal in a FGD environment, it was estimated that applied current could almost be spent to protect area near the anode. However, if cathodic protection is applied to high resistant-coated metal, the much larger area from the anode could be effectively protected.

Recent Research Trend in Fuel Cell Durability Model for Prediction of Stack Degradation (연료전지 내구 특성 예측을 위한 모델 개발 연구동향)

  • Han, Jaeyoung
    • Prospectives of Industrial Chemistry
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2019
  • 최근 전 세계적으로 이상화탄소 배출규제에 대응하기 위해 신에너지를 동력원으로 하는 자동차에 관심이 증가하고 있다. 그중 이온 교환막 연료전지(PEMFC)는 내연기관을 대신에 자동차 동력원으로 많이 사용되어지고 있으며 양산화를 위한 노력을 전 세계적으로 하고 있다. 하지만 이러한 수소 자동차가 시장과 소비자의 요구 조건을 충족하기 위해서는 내구성을 개선하여야 한다. 현재 선진사들을 중심으로 수소 자동차의 내구성을 개선하기 위해 노력하지만, 대부분 실험적 방법으로 내구성의 분석 및 평가를 수행하고 있다. 하지만, 이러한 방법은 비용과 시간이 많이 들기 때문에 경제적이지 못하다. 본 기고문에서는 내구성에 영향을 받는 인자, 연료전지 시스템 내구성을 예측하고 평가할 수 있는 수소 자동차 내구성 모델 개발에 필요한 수식에 관한 연구, 그리고 내구성 개선을 위한 해석적 방법(simulation)에 관한 연구 동향을 소개하고자 한다.

Stack Allocation-based Memory Performance Improvement Technique on Android 2.3 Dalvik Virtual Machine (안드로이드 2.3 달빅 가상머신에서 스택 할당 기법을 통한 메모리 성능 향상 기법)

  • Lim, Yeong-Kyu;Kim, Cheong-Ghil;Kim, Shin-Dug
    • Journal of Digital Contents Society
    • /
    • v.12 no.4
    • /
    • pp.551-557
    • /
    • 2011
  • In this paper, we propose a stack allocation technique of Android Java objects in order to reduce the number of garbage collection which is one of major reason on Android performance degradation when running applications. The proposed technique is to allocate Java objects into stack rather than heap memory. To do so, stacked objects could escape the garbage collection process. We experiment the proposed technique in the latest Android 2.3 version. For the simulation, we take advantage of the well known Java benchmark, Caffeinemark, and our own. The result shows the performance degradation of Dalvik Virtual Machine execution time caused by the stack allocation of Java objects is very slight and the proposed method considerably reduces the frequency of garbage collection. This will increase application performance and give better user interfaces to Android phone users.

Evaluation of Wind-Induced Vibration for Multiple Stacks Using Numerical Analysis (전산 해석을 이용한 다중연돌의 유체유발진동)

  • Yang, Kwangheok;Park, Chaegwan;Kim, Hyeonjoon;Baek, Songyoul;Park, Soontae
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • Wind-induced vibration is a phenomenon that a struture is oscillated due to wind force such as buffeting, vortex shedding wake and etc., which is one of important characteristics to be considered for design in case that stack has significant slenderness ratio or low natural frequency. International design standards of stack define several criteria for evaluating the suitability of stack design, which describe the required design considerations for each range of design parameters and provide the instruction to verify the stack design against wind-induced vibration simply. However, there is a limitation that they cannot provide quantitative information in case code requirement cannot be satisfied due to constraints of plant space or economical design. In order to overcome the limiation of code, integrated numerical analysis of computational fluid dynamics, harmonic analysis and finite element analysis were proposed to investigate wind-induced vibration for multiple stacks in actual plant. Simulated results of mutual wake interference effect between adjacent stacks were evaluated and compared to the criteria in international standards.

  • PDF

A Study on ESD Protection Circuit for 2-Stack Structure Design Based on LVTSCR (LVTSCR 기반의 2-Stack 구조 설계를 위한 ESD 보호회로에 관한 연구)

  • Seo, Jeong-Yun;Do, Kyoung-Il;Chae, Hee-Guk;Seo, Jeong-Ju;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.836-841
    • /
    • 2018
  • In this paper, This paper is based on the conventional ESD protection circuits SCR and LVTSCR. Also, the SCR-based ESD protection circuit, which is different from the conventional structure, is presented and tested for variations in the trigger voltage and holding voltage. Due to the insertion of additional N +, P + regions, the newly added SCR-based protection circuit have improved electrical characteristics. To discuss the electrical characteristics of the proposed circuit, Synopsys T-CAD simulation data was shown.

Constitution and Operation of a Molten Carbonate Fuel Cell System (용융탄산염형 연료전지 발전시스템 구성 및 운전)

  • Ahn, Kyo-Sang;Kim, Dong-Hyung;Seol, Jin-Ho;Lim, Hee-Chun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.100-103
    • /
    • 1997
  • Korea Electric Power Corporation (KEPCO) started a fuel cell project to develop alternative sources of electric power because of the rapid increase in power demand and global environmental problems. For the development of a molten carbonate fuel cell (MCFC), KEPCO started the project in 1993 to develop a 2 kW MCFC system and finished it at the end of 1996. In this project, $ASPEN^+$ was utilized to design the 2 kW MCFC generation system. Based on this simulation, a power generation system was designed and installed for operation and a long term test of internally manifolded 2 kW class MCFC stack. This stack has 20 cells with an effective electrode area of $1000\;cm^2$. It was run at 0.84 V and $150\;mA/cm^2$ and was operated for more than 3,250 hours continuously. This paper describes the system configuration and its control and measurement units. An analysis of the stack performance, the effect of gas utilization ratio, and the stack performance requirements are also discussed.

  • PDF

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

Numerical Studies of a Separator for Stack Temperature Control in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 스택 온도 조절을 위한 분리판에 관한 수치 해석 연구)

  • Kim, Do-Hyung;Kim, Beom-Joo;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.3
    • /
    • pp.305-312
    • /
    • 2011
  • The use of a separator to control stack temperature in a molten carbonate fuel cell was studied by numerical simulation using a computational fluid dynamics code. The stack model assumed steady-state and constant-load operation of a co-flow stack with an external reformer at atmospheric pressure. Representing a conventional cell type, separators with two flow paths, one each for the anode and cathode gas, were simulated under conditions in which the cathode gas was composed of either air and carbon dioxide (case I) or oxygen and carbon dioxide (case II). The results showed that the average cell potential in case II was higher than that in case I due to the higher partial pressures of oxygen and carbon dioxide in the cathode gas. This result indicates that the amount of heat released during the electrochemical reactions was less for case II than for case I under the same load. However, simulated results showed that the maximum stack temperature in case I was lower than that in case II due to a reduction in the total flow rate of the cathode gas. To control the stack temperature and retain a high cell potential, we proposed the use of a separator with three flow paths (case III); two flow paths for the electrodes and a path in the center of the separator for the flow of nitrogen for cooling. The simulated results for case III showed that the average cell potential was similar to that in case II, indicating that the amount of heat released in the stack was similar to that in case II, and that the maximum stack temperature was the lowest of the three cases due to the nitrogen gas flow in the center of the separator. In summary, the simulated results showed that the use of a separator with three flow paths enabled temperature control in a co-flow stack with an external reformer at atmospheric pressure.

Prediction Accuracy Enhancement of Function Return Address via RAS Pollution Prevention (RAS 오염 방지를 통한 함수 복귀 예측 정확도 향상)

  • Kim, Ju-Hwan;Kwak, Jong-Wook;Jhang, Seong-Tae;Jhon, Chu-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.3
    • /
    • pp.54-68
    • /
    • 2011
  • As the prediction accuracy of conditional branch instruction is increased highly, the importance of prediction accuracy for unconditional branch instruction is also increased accordingly. Except the case of RAS(Return Address Stack) overflow, the prediction accuracy of function return address should be 100% theoretically. However, there exist some possibilities of miss-predictions for RAS return addresses, when miss-speculative execution paths are invalidated, in case of modern speculative microprocessor environments. In this paper, we propose the RAS rename technique to prevent RAS pollution, results in the reduction of RAS miss-prediction. We divide a RAS stack into a soft-stack and a hard-stack and we handle the instructions for speculative execution in the soft-stack. When some overwrites happen in the soft-stack, we move the soft-stack data into the hard-stack. In addition, we propose an enhanced version of RAS rename scheme. In simulation results, our solution provide 1/90 reduction of miss-prediction of function return address, results in up to 6.85% IPC improvement, compared to normal RAS method. Furthermore, it reduce miss-prediction ratio as 1/9, compared to previous technique.