• Title/Summary/Keyword: stack simulation

Search Result 240, Processing Time 0.027 seconds

Analysis of the Homogenization of the Elastic Behavior for a Sheet with Sheared Protrusions using Hexahedral Mesh Coarsening (육면체 요소 재구성을 통한 개방형 사다리꼴이 성형된 판재의 탄성 거동 균질화에 대한 연구)

  • Lee, C.W.;Yang, D.Y.;Park, J.S.;Kang, D.W.
    • Transactions of Materials Processing
    • /
    • v.23 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • The current collector for the molten carbonate fuel cell (MCFC) which has sheared protrusions is manufactured by the three-stage forming process that integrates slitting, preforming and final forming. Due to the repetition of sheared protrusions, an effective simulation method is required to predict the mechanical behavior. In the current study, a sheet with sheared protrusions was assumed to be an orthotropic plate, which has the same length, width and height. FEM simulations were conducted to evaluate the homogenized properties of the current collector, which has 4 (longitudinal direction) x 4 (transverse direction) sheared protrusions. The simulation model was constructed using hexahedral mesh coarsening. From the verification examples, it was found that the proposed simulation method was efficient within reasonable accuracy. The calculated homogenized properties can be applied to the design of a stack for molten carbonate fuel cells and the prediction of mechanical behavior for other applications.

Current overshoot operation of a REBCO magnet to mitigate SCF

  • Lee, Changhyung;Hahn, Seungyong;Bang, Jeseok;Cho, Jeonwook;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • Due to large in-field current carrying capacity and strong mechanical strength, a REBCO wire has been regarded as a viable high temperature superconductor (HTS) option for high field MRI and > 1 GHz (>23.5 T) NMR magnets. However, a REBCO magnet is well known to have an inherent problem of field inhomogeneity, so-called 'Screening Current induced magnetic Field (SCF)'. Recently, 'field shaking' and 'current overshoot operation' techniques have been successfully demonstrated to mitigate the SCF and enhance the field homogeneity by experiments. To investigate the effectiveness of current overshooting operation technique, a numerical simulation is conducted for a test REBCO magnet composed of a stack of double pancake coils using '2D edge-element magnetic field formulation' combined with 'domain homogenization' scheme. The simulation result demonstrates that an appropriate amount of current overshoot can negate the SCF. To verify the simulation results, current overshoot experiments are conducted for the REBCO magnet in liquid nitrogen. Experimental results also demonstrate the possible application of current overshoot technique to mitigate the SCF and enhance the field homogeneity.

Simulation and Process Design of Pervaporation Plate-and-Frame Modules f3r Dehydration of Organic solvents (유기용매 탈수를 위한 투과증발 판틀형 모듈의 전산모사와 공정설계)

  • C. K. Yeom;Majid Kazi;Fakhir U. Baig
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.226-239
    • /
    • 2002
  • A process simulation model of pervaporation process has been developed as a design tool to analyse and optimize the dehyhration of organic solvents through a commercial scale of pervaporative plate-and-frame modules that contain a stack of membrane sheets. In the simulation model, the mass balance, the heat balance and the concentration balance are integrated in a finite elements-in-succession method to simulate the overall process. In the integration method, a feed channel between membrane sheets in the modules was taken as differential unit element volume to simplify calculation procedure and shorten computing time. Some of permeation parameters used in the simulation model, were quantified directly from the dehydration experiment of ethanol through $AzeoSep^{TM}$-2002 membrane which is a commercial pervaporation membrane. The simulation model was verified by comparing the simulated values with experimental data. Using the model, continuous and batch pervaporation processes were simulated, respectively, to acquire basic data for analysing and optimizing in the dehydration of ethanol through the membrane. Based on the simulation results, a comparison between the continuous and the batch pervaporation processes would be discussed.

Study on the design optimization of injection-molded DVD-Tray parts using CAE Simulation (플라스틱 DVD-Tray의 박막 사출성형을 위한 최적화 설계 Simulation에 관한 연구)

  • Chung, Jae-Youp;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1726-1732
    • /
    • 2008
  • Injection molding is one of plastic forming technology which can easily mass-produce plastic parts with various and even complex shape. The technology has lots of difficulties in making a good part due to phase change of material, high applied pressure, and fast melt flow speed in the cavity. To overcome the problems, they had to make trial and error method until the CAE(Computer Aided Engineering) could be a tool for concurrent engineering. In this paper, we investigate the optimal design for a plastic DVD tray part by systematic approach of the commercial CAE program. In design, we should consider two objectives which are both dimensional stability and cost-down. The dimension of the part is crucial because the tray should carry a DVD correctly, but the part is too thin to injection-mold easily. In order to improve the moldability, the mold is designed in the form of stack mold which is a kind of 4 hot runner system. In first, we changed the stack-mold system with one hot-runner to cost down, and decided the optimal position of the gate. After that, we investigate the effect of both the layout of cooling channels and the cooling temperature on the shrinkage of the DVD tray. A optimal simulation approach, the gate design is 2Gate#3 and the layout is Case2 cooling line as the optimal temperature of $70^{\circ}C$. The Moldflow and PC+ABS are used for the CAE program and material respectively.

$DEVSim ++^ⓒ$을 이용한 AS/RS의 Modeling 및 Simulation

  • 김용재;황문호;김탁곤;최병규
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1994.10a
    • /
    • pp.7-8
    • /
    • 1994
  • 최근 들어 원자재, 재공품 또는 완제품을 신속하고 정확하게 공급/배분하기 위해 저장과 인출을 담당하는 Material Handling System을 이용하여 작업자의 개입요소를 줄이며, 제고관리 Computer를 이용하여 입고/출고 명령을 유효적절하게 처리하는 ASRS(Atomated Storage and Retreival System : 자동창고 시스템)가 널리 공급되고 있다. 중앙은행의 현금창고, 병원의 약품창고, 식품/화장품 회사의 배송창고, 군수물자의 군납창고에 이르기까지 물품의 저장 또는 공급의 필용성을 갖는 곳에서는 어디든지 찾아볼 수 있는 ASRS는 가깝게는 관공소나 대형빌딩의 주차장에도 이의 개념이 도입되어 사용됨을 볼 수 있다. 최근의 인금인상, 구인난등의 이유로 ASRS설치는 계속 증가할 추세에 있으나 자동 창고 시스템을 설치하기 위해서는 막대한 초기 투자가 필요하며 시스템의 설계 및 설치후 운영에 대한 연구가 반드시 필요하다. ASRS의 운영 Rule 검증, 수행능력 분석등의 목적을 갖는 연구에는 여러 접근방법이 있을 수 있으나 구성 설비와 운영 Rule의 복잡한 관계로 컴퓨터 시뮬레이션의 거의 유일한 문제해결 방법이다. ASRS의 Modeling에 관한 기존의 연구로는 수리모델 수립. 이산사건 시스템의 관점에서 event-graphy, petri-net을 이용한 modeling이 있으며 ASRS에 대한 전용 Simulator 개발등이 진행되었다. 본 연구의 대상 시스템은 2개의 Rack과 하나의 Stacker Crane 으로 구성된 Aisle과 입출고의 물류를 처리하는 순환 RGVS(Rail Guided Vehicle System), 입/출고장을 구성하는 Conveyor Net등으로 이루어진 제조-물류시스템의 일반적인 ASRS이다. 또 이 ASRS의 입/출고 방식은 전수 입/출고만을 포함하며 Blocking 방지를 위한 Capaicty 예약, 다중설비 선택등의 문제등을 고려하고 있다. 본 연구의 접근방법으로는 ASRS의 개념적인 Reference Model을 수립하고 이 Reference Model에 대한 Formal Model로 DEVS(Discrete Event System Specification)을 이용하여 시스템을 Modeling하였다. 이의 Computer Simulation을 위하여 DEVS형식론 환경에서의 Simulation Language인 DEVSim ++ⓒ를 이용하여 시스템을 구현하였다.

  • PDF

Study on the Characteristics of Low-pressure Automotive Polymer Electrolyte Membrane Fuel Cell System Efficiency with Blower Configuration (블로워 구성 변경에 따른 상압형 자동차용 고분자전해질형 연료전지 시스템의 효율 특성 연구)

  • KIM, IL-JOONG;LEE, JUNG-JAE;KIM, HAN-SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.181-189
    • /
    • 2018
  • Polymer electrolyte membrane fuel cell (PEMFC) system receives great attention as a promising power device for automotive applications. For the wide commercialization, the efficiency and performance of automotive PEMFC system should be further improved in terms of total system (stack and balance of plant [BOP]). Air supply module, which is a major part of the BOP, greatly affects the efficiency of automotive PEMFC system. In this paper, a systematic study on the low-pressure automotive PEMFC system was made in an attempt to enhance the net system efficiency. This study mainly presents an investigation of the effect of blower configuration (1-blower and 2-blower) on the net system efficiency of automotive PEMFC system. For this purpose, the effect of operating pressure and cathode stoichiometry on the system efficiency was investigated with stack temperature under the fixed net system power condition. Results indicate that 1-blower system is better in system efficiency over 2-blower system under an air stoichiometry of 2. However, 2-blower system is better in system efficiency under an air stoichiometry of 3. The simulation results show that the optimum operating strategy needs to be established for various blower system configurations considering blower performance maps.

Simulation Experiment of PEMFC Using Insulation Vessel at Low Temperature Region (저온영역에서 단열용기를 이용한 연료전지 모의 실험)

  • Jo, In-Su;Kwon, Oh-Jung;Kim, Yu;Hyun, Deok-Su;Park, Chang-Kwon;Oh, Byeong-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.403-409
    • /
    • 2008
  • Polymer electrolyte membrane fuel cell (PEMFC) is very interesting power source due to high power density, simple construction and operation at low temperature. But it has problems such as high cost, improvement of performance, effect of temperature and initial start at low temperature. These problems can be approached to be solved by using experiment and mathematical method which are general principles for analysis and optimization of control system for heat and hydrogen detecting management. In this paper, insulation vessel and control system for stable operation of fuel cell at low temperature were developed for experiment. The constant temperature capability and the heating time at sub-zero temperatures with insulation control system were studied by using a heating bar of 60W class. PEMFC stack which was made by 4 cells with $50\;mc^2$ active area in each cell is a thermal source. Times which take to reach constant temperature by the state of insulation vacuum were measured at variable environment temperatures. The test was performed at two conditions: heating mode and cooling mode. Constant temperature capability was better at lower environment temperature and vacuum pressure. The results of this experiment could be used as basis data about stable operation of fuel cell stack in low temperature zone.

Buffer Overflow Malicious Code Detection by Tracing Executable Area of Memory (메모리 실행영력 추적을 사용한 버퍼오버플로 악성코드 탐지기법)

  • Choi, Sung-Woon;Cho, Jae-Ik;Moon, Jong-Sub
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.5
    • /
    • pp.189-194
    • /
    • 2009
  • Most of anti-virus programs detect and compare the signature of the malicious code to detect buffer overflow malicious code. Therefore most of anti-virus programs can't detect new or unknown malicious code. This paper introduces a new way to detect malicious code traces memory executable of essentials APIs by malicious code. To prove the usefulness of the technology, 7 sample codes were chosen for compared with other methods of 8 anti-virus programs. Through the simulation, It turns out that other anti-virus programs could detect only a limited portion of the code, because they were implemented just for detecting not heap areas but stack areas. But in other hand, I was able to confirm that the proposed technology is capable to detect the malicious code.

A Study on Mount Vibration Reduction of a Centrifugal Turbo Blower for FCEV (FCEV용 원심형 터보 블로워의 마운트 진동 저감에 관한 연구)

  • Kim, Yoon-Seok;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.10
    • /
    • pp.1073-1081
    • /
    • 2008
  • A centrifugal turbo blower of the fuel cell electric vehicle (FCEV) operates at very high speed above 30000 rpm in order to increase the pressure of the air, which supplied to a stack of FCEV, using rotation of its impeller blades. Vibration which originated from the blower is generated by unbalance of mechanical components, rotation of bearings and rotating asymmetry that rotate at high speed. The vibration is transmitted to receiving structure through vibration isolators and it can causes serious problems in the noise, vibration and harshness(NVH) performance. Thus, the study about reducing this kind of vibration is an important task. In this paper, dynamic analysis of the blower executed by numerical simulation and experimental analysis of the blower is also performed. Then, measured and simulated results are compared in order to validate of the simulation. Finally, reducing vibration through modifying mount stiffness is the main purpose of this paper.

Simulation Study of NOx Dispersion from Power Plant Stack Gas (화력발전소 배출가스 중 질소산화물의 확산에 관한 연구)

  • Park, Mi-Jeong;Jo, Young-Min;Sung, Doo-Yong;Kim, Mi-Jeong;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.540-550
    • /
    • 2013
  • Various efforts have been explored to save the cost in many industrial fields. In order to recover the residual thermal energy from the flue gas, an extreme high efficiency heat exchanger is planning to install at a power plant. The gas temperature will be reduced to $40^{\circ}C$ from $115^{\circ}C$. Thus gas buoyancy decreases, and dispersion of nitrogen oxides is expected to deteriorate as increasing relative humidity. In this study, the conversion of nitrogen monoxide to nitrogen dioxide and dispersion regime are investigated through computational modeling. Nitrogen dioxide which indicates 0.1 ppm at 85 m from the ground could be propagated to 620 m at $115^{\circ}C$ of the flue gas, whilst when cooled down to $40^{\circ}C$, it expands up to 750 m. The ground level influence area showed more expansion of dispersion, approximately to 930 m.