• Title/Summary/Keyword: stack

Search Result 2,230, Processing Time 0.03 seconds

Temperature Characteristics of the Molten Carbonate Fuel Cell Stack (용융탄산염형 연료전지의 스택구조와 온도특성)

  • Lee, Choong-Gon;Ahn, Kyo-Sang;Park, Seong-Yeon;Seo, Hai-Kyung;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.1
    • /
    • pp.54-61
    • /
    • 2004
  • Temperature characteristics in a stack of molten carbonate fuel cell (MCFC) have been investigated with simulation based on the computational fluid dynamics (CFD) codes and experimental way. The MCFC has generally two stack structures when the natural gas is used as fuel; one is the external reforming type and the other is internal reforming type. Computer simulation at the external reforming stack suggests that the maximum temperature in the stack depends on the gas flow length. The 2 kW MCFC stack with 25 cm gas flow length showed about $675^\circ{C}$ of maximum temperature.

The Study on Noise Reduction of a Industrial stack (산업용 Stack의 방음대책에 대한 연구)

  • Oh, Jin-Woo;Kwon, Byoung-Ha;Lee, Jang-Hyun;Lee, Hyo-Haeng;Lee, Kyu-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.462-467
    • /
    • 2008
  • 산업용 Stack은 높은 위치의 지리적 특징과 낮은 주파수의 음향특성으로 인해 발생소음도 자체를 감소시키는 것이 무엇보다 중요하다. 대표적인 방음대책은 소음기가 있으나 규모가 크고 테스트를 위한 경제적인 부담이 크므로 이론적, 해석적인 검토를 통해 Stack 소음기의 형태를 선정하고 실제 적용 현장에서의 소음기 성능을 측정하여 예측결과를 평가하였다. 산업용 Stack 소음기의 경우 소음기의 구조에 대한 문제 및 저주파 성분이 높은 Stack 소음 특성을 고려하여 조건에 적합한 +형 스프리터 소음기를 설계, 적용하였다. 현장측정결과 문제대역인 저주파 대역에서 뚜렷한 소음감소를 나타내는 것을 알 수 있었다.

  • PDF

A Sutdy on the Pressure Distribution Characteristic of High-rise Buildings in Fire Using Computer Simulation (시뮬레이션을 이용한 화재 시 고층건축물의 압력분포 특성에 관한 연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.49-50
    • /
    • 2019
  • In the case of High-rise buildings, it has a problem by stack effect that rise of vertical height. Especially in case of fire, it need to the consideration of stack effect that it has bigger than general. Therefore in this study, we used to the Contamw and FDS simulation for analysis of stack effect and pressure distribution characteristic in fire. As a result the Contamw simulation shows the pressure distribution by stack effect in general high-rise buildings. However, in case of fire, the height of the neutral plane is lowered and stack effect is larger. Therefore, it is necessary to multiply analyze the temperature distribution and the stack effect in fire.

  • PDF

Improving Stack LSTMs by Combining Syllables and Morphemes for Korean Dependency Parsing (Stack LSTM 기반 한국어 의존 파싱을 위한 음절과 형태소의 결합 단어 표상 방법)

  • Na, Seung-Hoon;Shin, Jong-Hoon;Kim, Kangil
    • Annual Conference on Human and Language Technology
    • /
    • 2016.10a
    • /
    • pp.9-13
    • /
    • 2016
  • Stack LSTM기반 의존 파싱은 전이 기반 파싱에서 스택과 버퍼의 내용을 Stack LSTM으로 인코딩하여 이들을 조합하여 파서 상태 벡터(parser state representation)를 유도해 낸후 다음 전이 액션을 결정하는 방식이다. Stack LSTM기반 의존 파싱에서는 버퍼 초기화를 위해 단어 표상 (word representation) 방식이 중요한데, 한국어와 같이 형태적으로 복잡한 언어 (morphologically rich language)의 경우에는 무수히 많은 단어가 파생될 수 있어 이들 언어에 대해 단어 임베딩 벡터를 직접적으로 얻는 방식에는 한계가 있다. 본 논문에서는 Stack LSTM 을 한국어 의존 파싱에 적용하기 위해 음절-태그과 형태소의 표상들을 결합 (hybrid)하여 단어 표상을 얻어내는 합성 방법을 제안한다. Sejong 테스트셋에서 실험 결과, 제안 단어 표상 방법은 음절-태그 및 형태소를 이용한 방법을 더욱 개선시켜 UAS 93.65% (Rigid평가셋에서는 90.44%)의 우수한 성능을 보여주었다.

  • PDF

Enhancement of Internal Network Security in Small Networks Using UTM and ELK Stack (UTM과 ELK Stack을 활용한 소규모 네트워크의 내부망 보안 강화방안)

  • Song Ha Min;DongHwi Lee
    • Convergence Security Journal
    • /
    • v.24 no.1
    • /
    • pp.3-9
    • /
    • 2024
  • Currently, cyberattacks and security threats are constantly evolving, and organizations need quick and efficient security response methods. This paper proposes ways to strengthen internal network security by utilizing Unified Threat Management (UTM) equipment to improve network security and effectively manage and analyze the log data of the internal network collected through these equipment using Elastic Stack (Elasticsearch, Logstash, Kibana, hereinafter referred to as ELK Stack).

Position Tolerance를 포함한 모형의 Stack Analysis 비교연구

  • 김영남;장성호
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.05a
    • /
    • pp.99-103
    • /
    • 2002
  • It is the basic requirement of product characteristics to specify geometric dimensions and tolerances during design process of parts assembly. Therefore, there are many tolerance stack analysis method to explain tolerance zone. Tolerance stack analysis is to calculate gap using tolerances which includes geometric and coordinate dimension. In this study, we compared several different stack analysis method and try to suggest more general method called the Virtual Method to analyze tolerance stack.

  • PDF

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack

  • Homma, Shin;Maeda, Junji;Hanada, Naoya
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.333-347
    • /
    • 2009
  • Many tower-supported steel stacks have been constructed in Japan, primarily for economic reasons. However the dynamic behavior of these stacks under a strong wind is not well known and the wind load design standard for this type of a stack has not yet been formulated. In light of this situation, we carried out wind response observation of an operating tower-supported steel stack with and without a tuned-mass damper. The observation revealed the performance of the tuned-mass damper installed on the stack in order to control the wind-induced vibration. Based on the observed data, we performed a wind tunnel test of a specimen of the stack. In this paper we report the results of the wind tunnel test and some comparisons with the results of observation. Our findings are as follows: 1) the tuned-mass damper installed on the specimen in the wind tunnel test worked as well as the one on the observed stack, 2) the amplitude of the vortex-induced vibration of the specimen corresponded approximately to that of the observed stack, and 3) correlation between Scruton number and reduced amplitude, y/d, (y is amplitude, d is diameter) was confirmed by both the wind tunnel test and the observed results.

A study on application of an E/V shaft cooling system to reduce the stack effect in high-rise building (연돌효과 저감을 위한 E/V샤프트 냉각장치의 적용에 대한 연구)

  • Lim, Hyun-Woo;Lee, June-Ho;Seo, Jung-Min;Lee, Jung-Hun;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.284-292
    • /
    • 2009
  • The stack-effect in high-rise buildings in winter causes many problems such as difficulties in opening or closing doors, infiltration, energy loss, noise and fire protection. Stack effect is influenced by temperature difference between the interior and exterior of building and the height of building. As an attenuation method for stack effect, the architectural methods are generally used. However, as though architectural methods were fully adopted, the problems are reported as ever in tall building. In this study, a new method to reduce stack effect will be suggested. As an active control method against the stack effect, E/V shaft natural cooling method is suggested. In this paper, the concept of E/V shaft natural cooling system and its reduction performance of stack effect by simulation and field measurement will be reported.

  • PDF

Study on 3D Numerical Analysis of Stack Effect Reduction in Stairwell of Building (건축물 계단에서의 연돌효과 저감방안에 대한 3차원 수치해석 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.152-157
    • /
    • 2015
  • Stack effect on high-rise building have negative effect on living environment, energy and life-safety aspect. Thus, it's necessary to find the measure to reduce the stack effect. As a result of field test on a 31-story building, a circulating type stack effect reduction technology was developed, which supplies air in the low stairs and discharges air in the high stairs. To evaluate the performance of this circulating type stack effect reduction technology on building stairs, a 3D numerical analysis was carried out by using Momentum Loss Model for analyzing leakage flow between compartments in a building. Consequently, numerical analysis proved that the stack effect on building stairs was reduced by a circulating type stack effect reduction technology.