• Title/Summary/Keyword: stability period

Search Result 1,552, Processing Time 0.032 seconds

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Studies on Characteristics and Stability of Anthocyanin Pigment Extracted from Korean Purple - Fleshed Potatoes (한국산 유색감자 색소의 특성 및 안정성에 관한 연구)

  • Park, Hong-Ju;Jeon, Tae-Woog;Lee, Sung-Hyeon;Cho, Yong-Sik;Cho, Soo-Muk;Chang, Kyu-Seob
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.9
    • /
    • pp.1544-1551
    • /
    • 2004
  • Effects of pH, sugar, ascorbic acid, organic acids and light sources on the stability of anthocyanin pigment extracted from Korean purple-fleshed potatoes (PL-6, PL-28, PL-31 and Jasim) were studied. The pH had remarkable influence on the color stability of anthocyanin pigment. With increasing pH, the color gradually fades as colorless pseudobases are formed. In acidic pH, anthocyanin was stable, but with increasing pH the color gradually changed to colorless. The addition of sugar decrease in color stability of the pigment during storage period. The most of organic acids, such as a tartaric, citric and succinic acids, were found to improve the stability of the pigment, while malic and malonic acid reduced the stability of the pigment. The addition of ascorbic acid considerable decreased in anthocyanin pigment stability, but the effect was not decreased by adding thiourea. The effect of light sources such as a darkroom, a fluorescent light, and sunlight, reduced gradually the stability of anthocyanin pigment. Therefore the pigment degradation could be minimized by shielding the light from the pigment.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

Seismic Vulnerability Analysis of River Levee by Earthquake Return Period (지진 재현주기에 따른 하천 제방의 지진취약성 분석)

  • Kim, Kyung-Oh;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.679-686
    • /
    • 2020
  • In this study, the seismic vulnerability of public river levees was analyzed quantitatively. Input seismic waves were generated in Pohang seismic waves in return periods of 200, 500, 1000, and 2400 years. The behavior of the levee was analyzed by seismic vulnerability analysis according to the return period. The displacement that occurs during an earthquake showed the same tendency as the input seismic wave and was largest in the return period of 2400 years. An analysis of the sliding stability revealed a 31.5% and 26.7% decrease in the sliding safety factor for the return period of 2400 for the landside and waterside, respectively. An examination of liquefaction by the q/p' ratio showed that the seepage line inside the embankment rises due to earthquakes. As a result, in the case of a return period of 2400 years, most embankments generate liquefaction, making them vulnerable to earthquakes. Through this research, it will be necessary to re-establish domestic seismic-design standards and establish clear standards for the results through a dynamics method.

Study of the Curing Time of Cementless Cold Central Plant Recycled Asphalt Base-Layer through Field-Application Review (무시멘트 상온 재활용 아스팔트 기층의 현장 적용성을 통한 양생기간에 관한 연구)

  • Choi, Jun Seong;Jung, Chul Ho;Lee, Chan Hee;Lim, in su
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.67-74
    • /
    • 2017
  • PURPOSES : The objective of this study is to ascertain the curing period of cementless cold central plant recycled asphalt base-layer, using mechanical analyses and specimen quality tests on the field. METHODS : Cold central plant recycled asphalt base-layer mixture was produced in the plant from reclaimed asphalt, natural aggregate, filler for the cold mix, and the modified emulsion AP using asphalt mix design and plant mix design. In order to examine the applicability of the curing period during the field test, the international standards for the possibility of core extraction and the degree of compaction and LFWD deflection were analyzed. Moreover, Marshall stability test, porosity test, and indirect tensile strength test were performed on the specimens of asphalt mix and plant mix design. RESULTS : The plant production process and compaction method of cementless cold central plant recycled asphalt base-layer were established, and the applicability of the optical moisture content for producing the mixture was verified through the field test. In addition, it was determined that the core extraction method of the conventional international curing standard was insufficient to ensure performance, and the LFWD test demonstrated that the deflection converges after a two-day curing. However, the back-calculation analysis reveals that a three-day curing is satisfactory, resulting in a general level of performance of dense asphalt base-layer. Moreover, from the result of the specimen quality test of the asphalt mix design and plant mix design according to the curing period, it was determined that the qualities satisfied both domestic and international standards, after a two-day curing. However, it was determined that the strength and stiffness after three-day curing are higher than those after a two-day curing by approximately 3.5 % and 20 %, respectively. CONCLUSIONS:A three-day curing period is proposed for the cementless cold central plant recycled asphalt base-layer; this curing period can be demonstrated to retain the modulus of asphalt-base layer in the field and ensure stable quality characteristics.

High Speed Precision Control of Mobile Robot using Neural Network in Real Time (신경망을 이용한 이동 로봇의 실시간 고속 정밀제어)

  • 주진화;이장명
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.1
    • /
    • pp.95-104
    • /
    • 1999
  • In this paper we propose a fast and precise control algorithm for a mobile robot, which aims at the self-tuning control applying two multi-layered neural networks to the structure of computed torque method. Through this algorithm, the nonlinear terms of external disturbance caused by variable task environments and dynamic model errors are estimated and compensated in real time by a long term neural network which has long learning period to extract the non-linearity globally. A short term neural network which has short teaming period is also used for determining optimal gains of PID compensator in order to come over the high frequency disturbance which is not known a priori, as well as to maintain the stability. To justify the global effectiveness of this algorithm where each of the long term and short term neural networks has its own functions, simulations are peformed. This algorithm can also be utilized to come over the serious shortcoming of neural networks, i.e., inefficiency in real time.

  • PDF

A STUDY ON THE ENGINE PERFORMANCE OF A SPARK IGNITION ENGINE ACCORDING TO THE IGNITION ENERGY

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • The more or less homogeneous fuel-air mixture that exists at the end of the compression process is ignited by an electric ignition spark from a spark plug shortly before top dead center. The actual moment of ignition is an optimization parameter; it is adapted to the engine operation so that an optimum combustion process is obtained. Brake mean effective pressure (BMEP) of the spark ignition energy control device (IECD) than conventional spark system at the stoichiometric mixture is increased about 9%. For lean burn engine, the lean limit is extended about 25% by using the IECD. It was considered the stability of combustion by the increase of flame kernel according to the high ignition energy supplies in initial period and discharge energy period lengthen by using the IECD.

Immediate Loading of Implants ; Recent Review (임플란트의 즉시 기능에 관한 최신 지견)

  • Kim, Yun-Sang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Traditionally, the implant treatment require load-free healing period of at least 3 months in the mandible and 6 months in the maxilla. But this long healing period provides patients with the discomfort and economical trouble. Many experiments has been attempted for the outcome of such disadvantage, so recently the immediate loaded implant is getting popularity. Several literature has been published for clinical success of immediate loaded implant. The studies for the success rate of immediate loaded implant in multi-way has been reporting, nevertheless, we don't have yet a probable success. Various studies have been practiced that the advantages and disadvantages associated with immediate loaded implant, and factors that may influence the success of immediate implant, including patient selection, type of bone quality, required implant length, structure of the implant, surgical skill, need for achieving primary stability, control of occlusal force, peri-implant bone activity. The objective of this study is to review the literature related to immediate loading of implants and to discuss factors that may influence this treatment modality, based on scientific evidence.

Quality and Storage Stability of Hamburger during Low Temperature Storage (저온저장에 의한 햄버거의 품질 및 저장 안전성)

  • 송형익;문귀임;문윤희;정인철
    • Food Science of Animal Resources
    • /
    • v.20 no.1
    • /
    • pp.72-78
    • /
    • 2000
  • This study was conducted to investigate the storage period and quality characteristics. The L- and b-value of hamburger patty added significantly during storage, but the color of hamburger bread was not changed. The springiness, cohesiveness, gumminess and chewiness of hamburger patty added significantly during storage. The cohesiveness of hamburger bread was added but the chewiness decreased significantly during storage. The pH of hamburger showed 5.66∼5.69 during storage. The TBA of hamburger patty added from 0.19 to 0.36 malonaldehyde mg/kg, and the VBN added from 3.58 to 7.83mg% during storage. The viable bacteria to 8 days storage was 5.1${\times}$105 CFU/g. The coliform group, Staphylococcus aureus, Salmonella and Vibrio parahaemolyticus was not detected during storage. The taste, aroma, color and texture was not changed, and was not appearance of mold and slime during storage.

  • PDF

Physiological characterization of SP816 bacteriophage (SP816 박테리오파아지의 생리적 특성)

  • 이오형
    • Korean Journal of Microbiology
    • /
    • v.24 no.2
    • /
    • pp.161-167
    • /
    • 1986
  • Some of the physiological properties of Sp816 bacteriophage of Bacillus subtilis SNU816 were characterized. It could form plaques on either B. subtilis SNU816 or B. natto 8102, but not on any other bacillus strains investrgated. Its plaque morphology was circular with a diameter of less than 1.0mm and had a narrow halo surrounding the clear center. Its latent period was 34-36 min and had a burst size of 547. It was most stable at pH 6.0, and rapidly inactivated at $60^{\circ}C$ with a initial deaty rate of -0.216 $min^{-1}$. Host range, thermal inactivation rate at $60^{\circ}C$, pH stability, and UV sensitivity revealed that SP816 was quite different from any other phages investigated together but seemed to be rather related to B. natto phages.

  • PDF