• 제목/요약/키워드: squirrel cage induction motor

검색결과 153건 처리시간 0.022초

SMART용 냉각재순환펌프에 장착되는 농형유도전동기의 전자기 및 열해석 (Electromagnetic and Thermal Analysis of Squirrel Gage Canned Induction Motor for SMART Main Coolant Pump)

  • 허형;구대현;강도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.308-311
    • /
    • 1999
  • A squirrel cage canned induction motor for the main coolant pump of the integral reactor, SMART was designed, manufactured and tested. The motor was first designed using the equivalent circuit theory to determine major dimensions and then finalized through finite element analyses for electromagnetic and thermal characteristics. In order to verify the design methodology, a reduced scale canned induction motor was manufactured and tested. The experimental results have shown a good agreement with the analysis results.

  • PDF

5상 1.5kW 농형 유도전동기의 운전특성 (Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW)

  • 김민회;정형우;송현직
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

유한요소법을 이용한 농형유도전동기의 회전자 불량 진단에 관한 연구 (A Study on the Fault Diagnosis of Rotor Bars in Squirrel Cage Induction Motors by Finite Element Method)

  • 김창업;정용배
    • 한국자기학회지
    • /
    • 제6권5호
    • /
    • pp.287-293
    • /
    • 1996
  • 농형유도전동기의 회전자는 제조 과정중에 회전자 도체의 단선, 기포 발생으로 인한 회전자 도체의 저항 증가, 스큐 불량 등 여러 가지 고장이 발생될 수 있다. 이와 같은 고장은 유도전동기의 성능을 저하시키므로 회전자를 조립하기 전에 고장 유무를판단하면 조립에 드는 제조 비용을 절약할 수 있고 전동기의 신뢰성을 높일 수 있다. 본 논문에서는 이와같은 고장을 진단하는 방법의 하나로 유한요소법을 이용하여 회전자가 회전할 때 발생하는 전자석 코일에서의 유도 전류 파형을 검출하여 고장을 진단하는 방법을 제안하였다. 제안한 방법의 타당성을 검층하기 위하여 5 Hp 삼상 농형유도전동기에 대해 고장전류를 검출하고 이를 해석 결과와 비교 분석하였다.

  • PDF

회전속도 변화에 따른 유도발전기의 특성 해석 (Characteristics Analysis of Induction Generator with a Change in Rotor Speed)

  • 김종겸;박영진;김일중;김영국
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2225-2229
    • /
    • 2011
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. However, many engineer are unfamiliar with the induction generator, even though no difference exists between both machines except for the mode of operation. But an induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load, total efficiency is decreased. In this paper, we analyzed that input, output, torque and efficiency is different from each other above and below synchronous speed.

5상 유도전동기 구동을 위한 수정된 직접 토크제어 시스템 (The Modified Direct Torque Control System for Five-Phase Induction Motor Drives)

  • 김민회;김남훈;백원식
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.138-147
    • /
    • 2009
  • 본 논문에서는 5상 농형유도전동기(Five-phase squirrel-cage induction motor)의 수정된 직접 토크제어(Direct torque control, DTC) 시스템을 제안한다. 5상 유도전동기 구동은 추가적인 자유도로 인하여 개선된 특성이 얻어짐과 동시에 일반적인 3상 유도전동기에 비해 토크의 맥동이 감소하며, 신뢰성 증가와 같은 장점을 가진다. 5상 유도전동기의 직접 토크제어는 인버터 구동시스템이 기존의 3상 인버터가 8개의 공간전압 벡터를 가지고 있는 것에 비해서 32개의 공간전압 벡터를 제공하기 때문에 여러 가지 장점이 있다. 그러나 5상 전동기의 경우는 제3공간 고조파 성분으로 인하여 구조적인 단점을 가지고 있어 고조파 성분의 전류제어가 요구된다. 따라서 이 논문에서는 5상 유도전동기의 특성을 개선하기 위하여 제3고조파 전류성분을 제어할 수 있는 수정된 직접 토크제어 시스템을 제시한다. 전통적인 5상 유도전동기의 직접 토크제어와 제안된 직접 토크제어 시스템의 운전특성을 검증하기 위하여, 디지털 제어기로 32[bit] 고정소수점 DSP인 TMS320F2812를 사용하여 2.2[kW] 5상 유도전동기의 속도제어 시스템을 구성하여 동특성을 관찰한 결과 우수한 특성이 얻어짐을 확인하였다.

벡터제어 유도전동기의 최대효율 운전 (Maximum Efficiency Drive of Vector-Controlled Induction Motors)

  • 윤덕용;최규하;홍순찬;백수현;이은웅
    • 전력전자학회논문지
    • /
    • 제1권1호
    • /
    • pp.27-37
    • /
    • 1996
  • This paper proposes the control algorithm for maximum efficiency drive of PWM inverter - induction motor system with high dynamic performance. If the induction motor is driven under light load with rated magnetizing current, the Iron loss is excessively large compared with the codder loss which results in doer motor efficiency. Maximum efficiency drive of an induction motor can be achieved by controlling the magnetizing current to satisfy the optimal ratio that leads the total motor loss to be a minimum value at a given speed. The proposed control algorithm essentially uses vector control technique and adopts voltage decoupling control strategy to prevent the degradation of dynamic performance due to reduced magnetizing current. To verify the proposed method, digital simulations and experiments are carried out for a squirrel-cage induction motor with the rating of 2.2[kW].

  • PDF

유한요소법에 의한 농형유도전동기 d-q 등가모델의 회로정수 산출 (Calculation of Equivalent d-q Model Parameters of A Squirrel Cage Induction Motor Using Finite Element Method)

  • 최종선;구태만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.315-317
    • /
    • 1999
  • This paper presents a method for determining of the equivalent d-q model parameters of three-phase squirrel cage induction motors. The method is based on the use of a finite-element field calculation which enables the precise slot geometry to be modelled accurately, and includes the effects of magnetic saturation of iron core. The proposed method can reduce computational costs compared with the method that needs the iterative field analysis to obtain the impedance. It is verified that the circuit inductances are shown as functions of the current.

  • PDF

복합고장을 가지는 농형유도전동기의 모델링과 웨이블릿 분해를 이용한 고장진단 (Fault Modeling and Diagnosis using Wavelet Decomposition in Squirrel-Cage Induction Motor Under Mixed Fault Condition)

  • 김연태;배현;박진수;김성신
    • 한국지능시스템학회논문지
    • /
    • 제16권6호
    • /
    • pp.691-697
    • /
    • 2006
  • 유도전동기는 산업시스템에 있어서 필수적인 요소이기 때문에 유지 관리, 모니터링 시스템, 고장 진단 등의 다양한 분야에서 많은 연구가 행해지고 있다. 유도전동기의 운전 중 하나의 고장이 발생한 경우 이것은 전동기의 다른 부분에 영향을 미치거나 또 다른 고장을 유발시키는 원인이 된다. 따라서 개별적인 고장뿐만 아니라 결합된 형태의 고장을 검출하고 진단하는 것은 유용한 방법이다. 본 논문에서는 전압불평형 고장과 회전자바 고장이 발생한 경우, 흐리고 두 고장이 동시에 복합적으로 발생한 경우를 모델링하고 이에 대해 고장을 웨이블릿 분해를 이용하여 진단하였다. 제안된 고장 검출 및 진단 알고리즘은 농형유도전동기의 고정자 전류를 이용하였으며 매트랩 시뮬링크를 사용하여 시뮬레이션 하였다.

슬롯조합에 따른 유도전동기의 공간자속분포 (Harmonic Flux Distribution of Induction Motor by Slot Combinations)

  • 이동주;이은웅;오영수;김종겸;손홍관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.18-20
    • /
    • 1997
  • In this paper, we analyze the harmonic flux distribution of squirrel cage induction motor with the different stator/rotor slot combination(36/42 and 36/44) using Finite Element Method and fast Fourier transform. These result will be used to obtain dips & cusps (harmonic torque) in torque characteristic curve.

  • PDF

기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정 (Selection of Motor Starting Method by Numeric Simulation)

  • 장중구;서상진;이민용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF