• Title/Summary/Keyword: square tube

Search Result 325, Processing Time 0.027 seconds

Brightness Property by Applied Frequency for External Electrode Fluorescent Lamp (EEFL) (External Electrode Fluorescent Lamp (EEFL)의 입력 주파수에 따른 휘도특성)

  • Lee, Seonh-Jin;Yang, Jong-Kyong;Choi, Yong-Sung;Lee, Sang-Hern;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.223-225
    • /
    • 2005
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, an EEFL presented the possibility of using it as a light source for backlights. However, because an EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verifies the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL frequency and brightness by measuring the optical characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Luminance Properties and Electrical Properties by Applied Frequency of External Electrode Fluorescent Lamp(EEFL) (EEFL의 주파수 변화에 따른 전기적 특성과 휘도특성)

  • Lee, Seong-Jin;Lee, Jong-Chan;Park, Noh-Joon;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.355-360
    • /
    • 2007
  • The recent TFT-LCD Trend that is done large size gradually. As size of monitor great, though problem happens, it is that consumer's request which it makes monitor combined TV function. Monitor and TV are no difference externally greatly, but define difference happens as for backlight. An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high Luminance using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and Luminance by measuring the optical characteristics.

Analysis of high-frequency resonant Inverter character using efficient ozonizer (고효율 오존생기용 고주파 공진형 인버터의 특성 해석)

  • Kim, Young-Hoon;Hwang, Young-Min;Noh, In-Bae;Kim, Young-Bin;Heo, Tae-Won;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

Forming Simulation of Extru-Bending Process Using Multi-Billets (멀티빌렛을 사용한 압출굽힘가공의 성형 해석)

  • Park D. Y.;Jin I. T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.120-123
    • /
    • 2004
  • The bending phenomenon has been known to be occurred by the difference of velocity at the die exit. The difference of velocity at the die exit section can be obtained by the different velocity of billets inside die chamber after passing the multi-hole container. The curvature can be controlled by the two variables, the one of them is the different velocity of billets through the multi-hole container, the other is the difference of hole diameter. The bending phenomenon during extruding using four billets can be obtained by the difference of hole diameters in the multi-hole container or by the difference of relative velocity of billet inserted in the container. As results of DEFORM-3D analysis, it can be shown that bending can be obtained during extruding by the difference of relative velocity of two billets or by the difference of hole diameter, and the amount of curvature is increased by the difference of velocity and diameter. According to the shape of products, the curvature of rectangular section is bigger than the curvature of regular square section. And, it is estimated that, because the stress on the welding line is much higher than yield stress of material, the bonding of four billets can be obtained.

  • PDF

Optical Characteristics of EEFL (External Electrode Fluorescence Lamp) for Large Size BLU (대화면 BLU용 EEFL의 광학적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.74-76
    • /
    • 2006
  • An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the ear1y stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significant1y affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and brightness by measuring the optical characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Effects of gum elastic bougie in intubation with difficult airway (마네킹을 이용한 어려운 기도에서 부지 기관 내 삽관의 효과)

  • Shim, Gyu-Sik;Bang, Sung-Hwan;Ahn, Hee-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.2
    • /
    • pp.123-131
    • /
    • 2020
  • Purpose: This study aimed to find out the effectiveness of gum elastic bougies for intubation in comparison to stylet according to airway type using a manikin. Methods: The study subjects were 52 paramedic students who intubated using a Macintosh laryngoscope and compared stylet and gum elastic bougie use in a 7.5 mmID endotracheal tube, on a manikin with either normal or difficult airway. Difficult airway was made Philadelphia neck collar. Collected data included intubation time, accuracy and ease of intubation, later analyzed by frequency analysis, descriptive analysis, independent t-test, chi square test, paired t-test, and McNemar test using SPSS Statistics 18.0. Results: There was a significant difference in intubation time according to intubation device and airway type (p=.000). There was no significant difference in accuracy of intubation according to intubation device or airway type (normal airway p=1.000, difficult airway p=.052). There was a significant difference in ease of intubation scale according to intubation device and airway type (p=.000, p=.000). Conclusion: Based on the speed and ease of intubation, gum elastic bougie is recommended for intubation in patients with difficult airways such as those with cervical injury.

Experimental and theoretical studies on SHS column connection with external stiffening ring under static tension load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Ma, Xu;Quan, Xinxin
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.167-177
    • /
    • 2018
  • In order to investigate mechanical properties in the core area of Square Hollow Section(SHS) column connection with external stiffening ring, four specimens were tested under the static tension load. The failure modes, load-displacement curves and strain distribution were analyzed to study the mechanical properties and the load transfer mechanism of the core area of connections. The connections behave good ductility and load-bearing capacity under the static tension load. Parametric analysis was also conducted, in which the thickness of steel tube, extended width and thickness of the stiffening ring were considered as the parameters to investigate the effects on mechanical properties of the connections. Based on the experimental results, an analytical method for the bearing capacity of connection with external stiffening ring under the static tension load was proposed. The theoretical results and the experimental results are in good agreement, which indicates that the theoretical calculation method of the bearing capacity is advisable.

An evaluation equation of load capacities for CFT square column-to-beam connections with combined diaphragm

  • Choi, Sung-Mo;Jung, Do-Sub;Kim, Dae-Joong;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • v.7 no.4
    • /
    • pp.303-320
    • /
    • 2007
  • The objective of this study is to clarify the structural features of members consisting of connection, as a series of the previous study on the CFT column-to-beam tensile connection with combined cross diaphragm. This connection has the merits that the stress is distributed evenly on the beam flange and the diaphragm and the stress concentration is reduced, by improving the stress transfer route and restraining abrupt deformation of diaphragm. The finite element analysis was performed to find out the stress transfer through sleeve which is an important member of the connection with combined cross diaphragm. The length and thickness of sleeve were used as variables for the analysis. As the analysis results, the length and thickness of sleeve didn't influence on the capacity of the connection and played a role of a medium to transfer the stress from the diaphragm to the filled concrete. It is proposed that the appropriate length of sleeve be the same value as the diameter of sleeve and the appropriate ratio of sleeve diameter to sleeve thickness be 20. Two equations for evaluation of the load-carrying capacity of the connection were also proposed through the modification of the evaluation equation suggested in the previous study.

Brightness Characteristics by Applied Frequency for External Electrode Fluorescent Lamp (외부전극형 형광램프의 입력 주파수에 따른 휘도 특성)

  • Choi, Yong-Sung;Cha, Jae-Chea;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.75-78
    • /
    • 2006
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainlyon its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, an EEFL presented the possibility of using it as a light source for backlights. However, because an EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verifies the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL frequency and brightness by measuring the optical. characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Predictors of Delirium in Patients after Orthopedic Surgery (정형외과 수술 후 섬망 발생요인 분석)

  • Chung, Mee Hye;Yun, Sun Ok;Park, Jeong Hee;Chu, Soon Ok;Oh, So Young;Kim, Mi Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.3
    • /
    • pp.443-454
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the predictors of delirium in patients after orthopedic surgery. Methods: Participants were 121 orthopedic surgery patients from one university affiliated hospital located in Seoul. The instrument of Delirium Observation Screening Scale (DOS) developed by Schuurmans et al. (2003) was utilized. Data were collected from September 1st, 2010 to March 31st, 2011 and analyzed using SPSS 12.0 with descriptive statistics, t-test, chi-square test and logistic regression. Results: The delirium in patients after orthopedic surgery was occurred in 9 (7.4%) out of 121 patients. Several factors were associated with the delirium occurrence age, admission route, preadmission Activity of Daily Living (ADL), preadmission hearing aid use, preadmission walking degree, diagnosis, type of surgery, Intensive Care Unit (ICU) stay after surgery, restraint, drainage tube, time of admission to surgery, preoperative albumin and preoperative sodium. Preadmission ADL, preoperative sodium and time of admission to surgery were the significant predictors of the delirium occurrence. Conclusion: Study results may help nurses predicting and detecting delirium early and providing preventive measures to the patients with high risk of delirium after orthopedic surgery.