• Title/Summary/Keyword: sprayed-coating

Search Result 327, Processing Time 0.023 seconds

Evaluation of Cavitation Characteristics for ALBC3 Alloy Coated with Ni-Cr Series Self Fluxing Alloy in Marine Environment (해양환경 하에서 Ni-Cr계 자용성 합금 코팅된 ALBC3 합금의 캐비테이션 특성 평가)

  • Lee, Seung-Jun;Kim, Seong-Jong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.538-544
    • /
    • 2013
  • In this study, cavitation characteristics of a thermal spray coating were evaluated in order to improve durability and cavitation resistance. For a coating material, a Ni-based self-fluxing alloy was thermal-sprayed over a ALBC3 alloy substrate and subsequently modified by heat treatment.The resulted self-fluxing coating layer had relatively high hardness compared to the base material, and thus would be expected to exhibit good durability. However, the cavitation characteristics were deteriorated due to the intrinsic porous structure of the coating. Therefore, it is essential to optimize heat treatment condition during thermal spraying coating process for self-fluxing alloy, and in this research the increase in heat treatment temperature is thought to increase the fluidity of B and Si in the self-fluxing alloy and to remove pores or defects, leading to the characteristics enhancement.

Improvement for Shielding Effectiveness of EMI Shield Layers using Conformal Spray Coating Scheme (콘포멀 스프레이 코팅으로 형성한 EMI 차단막의 차폐효과 개선)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.107-112
    • /
    • 2018
  • Shielding effectiveness (SE) improvement with EMI shield layers fabricated by conformal spray coating system was studied. Silver or Nickel powder filled acrylic resin were sprayed on the samples. We compared the performance with the viscosity of 400 cPs and 100 cPs cases. The thickness range of the coating layer was 20 to 50 um for the silver, 60 to 120 um for the nickel. The shielding effectiveness was measured by ASTM D4935 using coaxial type TEM-cell. The silver-filled resin showed much better performance than that of the nickel-filled resin. The shielding effectiveness increased almost proportional to the thickness of the coating layers until being saturated around 63 dB for the silver-layer or around 34 dB for the nickel-layer. The best performance measured in this study was the shielding effectiveness of 63 dB with $35{\mu}m-thick$ of silver-layer.

HISTOLOGIC EvALUATION OF BONE HEALING AROUND TITANIUM PLASMA SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS IN DOGS (성경 대퇴골에 매식된 Titanium Plasma Spray 및 Hydroxyapatite 피복임프란트 주위의 골치유 양상)

  • Huh, Ki-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.418-437
    • /
    • 1995
  • The effect of the hydroxyapatite coatings on Titanium implants has been the subject of recent investigations. So far, the use of HA coating remains substantially controversial.This study was aimed to evaluate histologically the bone healing patterns around titanium plasm sprayed(TPS) amd HA-coated implant after implantation into the femur neck of ten adult dogs. After implantation, animals were sacrificed at the intervals of 2,4,6,8 and 12 weeks.The fluorescent dyes were injected on the postoperative 4th and 12th week into the animals supposed to be killed at the 12th week. The morphology and direction of new bone formation was similar in both TPS and HA-coated implants.There was a tendency toward more bone formation in the cortical bone area than in the cancellous bone area. Histologically,in the interface of the HA-coated implants, bone response and bone maturation was faster, compared to the TPS implants in the 2nd and 4th week. By fluorescent microscopy, new bone formation was active in the 4th week around both implants and was directed from the periosteum overlying cortical bone to the cancellous bone. These results suggest that the bone formation and maturation is faster during the early healing stage in the interface of the HA-coated implant and where the cortical bone quality is poor, HA coated implant is superior to the TPS implant in the early phase of new bone formation.

  • PDF

Formation of YSZ Coatings Deposited by Suspension Vacuum Plasma Spraying (서스펜션 진공 플라즈마 용사법을 통한 YSZ 코팅의 형성)

  • Yoo, Yeon Woo;Byon, Eungsun
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.460-464
    • /
    • 2017
  • As increasing thermal efficiency of the gas turbine, the performance improvement of thermal barrier coatings is also becoming important. Ytrria stabilized zirconia(YSZ) is the most popular materials for ceramic top coating because of its low thermal conductivity. In order to enhance the performance of thermal barrier coatings for hot sections in the gas turbine, suspension plasma spraying was developed in order to feed nano-sized powders. YSZ coatings formed by suspension plasma spraying showed better performance than YSZ coatings due to its exclusive microstructure. In this research, two YSZ coatings were deposited by suspension vacuum plasma spraying at 400 mbar and 250 mbar. Microstructures of YSZ coatings were analyzed by scanning electron image(SEM) on each spraying conditions, respectively. Crystalline structure transformation was not detected by X-ray diffraction. Thermal conductivity of suspension vacuum plasma sprayed YSZ coatings were measured by laser flash analysis. Thermal conductivity of suspension vacuum plasma sprayed YSZ coatings containing horizontally oriented nano-sized pores and vertical cracks showed $0.6-1.0W/m{\cdot}K$, similar to thermal conductivity of YSZ coatings formed by atmospheric plasma spraying.

Characteristics of Plasma Sprayed TiO2-NiCr Conductive Heating Roll Coatings (가열 롤에서 플라즈마 TiO2-NiCr 용사피막의 특성)

  • Kang, Tae-Gu;Jin, Min-Seok;Ko, Young-Bong;Kim, Tae-Hyung;Cho, Sang-Hum;Park, Jung-Sik;Kim, Jong-Chul;Park, Kyeung-Chae
    • Journal of Welding and Joining
    • /
    • v.25 no.4
    • /
    • pp.28-34
    • /
    • 2007
  • The heating unit of direct heating method manufactured as the plasma spray coating of $TiO_2/NiCr$ conductive heating material on the surface of heating unit in order to improve the disadvantages of indirect heating method. $TiO_2$ and NiCr (80wt.%Ni-20wt.%Cr) that had the properties of conduction and heating was chosen for the conductive heating material. The compositions of the composite powders were studied $TiO_2-30wt.%NiCr\;and\;TiO_2-10wt.%NiCr$. As the heating temperature was increased, the hardness of heating layer was increased because of the fine microstructure and the decrease of porosity. The adhesion strength was decreased for coarsening and connection of voids in the insulation layer, and the electrical resistivity of heating layer was increased for fine crack formation and growth. In this study, the best efficient sprayed coatings with heating unit was concluded as the plasma sprayed $TiO_2-10wt.%NiCr$ coatings that was heat treated at $300^{\circ}C$.

Friction and Wear Properties of Plasma-sprayed Cr2O3-MoO3 Composite Coatings at High Temperature (MoO3가 첨가된 Cr2O3 플라즈마 용사코팅의 고온 마찰 마멸 특성)

  • Lyo, In-Woong;Ahn, Hyo-Sok;Lim, Dae-Soon
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.851-856
    • /
    • 2002
  • Tribological behavior of plasma-sprayed $Cr_2O_3$-based coatings containing $MoO_3$ at 450$^{\circ}C$ was investigated to understand the influence of $MoO_3$. A reciprocal disc-on-plate type tribo-tester was employed to examine fricition and wear behavior of the specimens. The microstructure and phase composition of the coating was characterized with Transmission Electron Microscopy(TEM). The TEM analysis indicated that $MoO_3$ was dispersed into the grain boundary, resulting in the increase of the hardness and density of the coating. Worn surfaces were investigated by scanning electron microscopy and chemistry of the worn surfaces was analyzed using a X-ray Photoelectron Spectrometer(XPS). The results showed that the friction coefficient of the $MoO_3$-added coatings was lower than that without $MoO_3$ addition. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with $MoO_3$ composition in the protecting layer appears to be more favorable in reducing the friction.

The Mechanical Properties of WC-CoFe Coating Sprayed by HVOF (고속화염용사코팅으로 제조된 WC-CoFe 코팅의 기계적 특성에 관한 연구)

  • Joo, Yun-Kon;Cho, Tong-Yul;Ha, Sung-Sik;Lee, Chan-Gyu;Chun, Hui-Gon;Hur, Sung-Gang;Yoon, Jae-Hong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.1
    • /
    • pp.6-13
    • /
    • 2012
  • HVOF thermal spray coating of 80%WC-CoFe powder is one of the most promising candidate for the replacement of the traditional hard chrome plating and hard ceramics coating because of the environmental problem of the very toxic $Cr^{6+}$ known as carcinogen by chrome plating and the brittleness of ceramics coatings. 80%WC-CoFe powder was coated by HVOF thermal spraying for the study of durability improvement of the high speed spindle such as air bearing spindle. The coating procedure was designed by the Taguchi program, including 4 parameters of hydrogen and oxygen flow rates, powder feed rate and spray distance. The surface properties of the 80%WC-CoFe powder coating were investigated roughness, hardness and porosity. The optimal condition for thermal spray has been ensured by the relationship between the spary parameters and the hardness of the coatings. The optimal coating process obtained by Taguchi program is the process of oxygen flow rate 34 FRM, hydrogen flow rate 57 FRM, powder feed rate 35 g/min and spray distance 8 inch. The coating cross-sectional structure was observed scanning electron microscope before chemical etching. Estimation of coating porosity was performed using metallugical image analysis. The Friction and wear behaviors of HVOF WC-CoFe coating prepared by OCP are investigated by reciprocating sliding wear test at $25^{\circ}C$ and $450^{\circ}C$. Friction coefficients (FC) of coating decreases as sliding surface temperature increases from $25^{\circ}C$ to $450^{\circ}C$.

Failure Analysis of Corroded Coating Materials by Acoustic Emission (음향방출법에 의한 용사코팅 피막부식재의 파손 해석)

  • KIM GUI-SHIK;HYUN CHANG-HAE;HONG YONG-UI;SHON CHANG-HWAN
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.43-49
    • /
    • 2005
  • This paper is to investigate the effect of corrosion by acoustic emission method in tensile loading and the adhesiveness between substrate and coating layer. The powders used are Zn and Amdry625, respectively. They are coated on brass alloy substrate. AE signals of Zn and Amdry625 coating layer increase drastically in strain $2\%$. However, those of Zn specimen have more than those of Amdry625 specimen. When the specimens executed the corrosion test under $3.5\%$ NaCl solution for 500, 1000 hours, the salt solution penetrated into the surface of the substrate through the pores of the coating layer. As a result, corrosion production formed on the surface of the substrate. The adhesiveness between coating layers is weakened by the polarization and corrosion itself. The AE event, count, and energy of corroded coating specimens decrease, compared to specimens without corrosion. The results are summarized as follows : 1. In the tensile tests, the time that it took to start and develop the cracks and exfoliations between the surface of the substrates and the plasma spray coatings were different according to the type of plasma sprayed material, which are Zn and Amdry625. These phenomena were obvious at the strain rate 1 to $5\%$, and few available data were found after that stage. 2. The specimens with Zn coating showed the characteristics of crack, according to the changes of the tensile strength applied on the substrates while those with Amdry625 showed exfoliation as a result of low adaptation to the tensile strength. 3. The anti-corrosion specimens showed that the adhesive properties between the substrate and the plasma spray coating were strong in the order of Zn, Amdry. It showed that Corroded specimens cracked or exfoliated easily, even with the small energy, because those had a comparatively weakened adhesive property, due to corrosion. 4. Zn specimen showed no corrosion phenomena on the surface of the substrates, because they had the function of sacrifice anode however, Amdry625 specimen showed the corrosion, because it did not have that function.

The Effect of Sodium Alginate Coating on the Storage Stability and Dissolution Rate of Enteric Coated Lansoprazole (알긴산 나트륨이 장용코팅된 란소프라졸 제제의 저장안정성 및 용출률에 미치는 영향에 관한 연구)

  • Kim, Jung-Hoon;Oh, Jung-Min;Khang, Gil-Son;Jeong, Je-Kyo;Lee, Jung-Sik;Jeung, Sang-Young;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.4
    • /
    • pp.277-284
    • /
    • 2002
  • Lansoprazole, pharmaceutics for acid-related diseases, is unstable in low pH environments and generally coated with enteric polymer to obtain gastroresistance in stomach. Because its storage stability is influenced by acidic substitutes of enteric polymer, alkaline chemicals wεre generally addεd to dosage form as a stabilizer. In this experience, we coated lansoprazole bead with sodium alginate and evaluated the effect of bead size and sodium alginate coating on the storage stability and dissolution profile of lansoprazole. Sodium alginate solution containing lansoprazole was sprayed as a droplet into 3% (w/v) $CaCl_2$ solution and the resultant bead was coated with starch, sodium alginate, and hydroxypropyl methylcellulose phthalate. The content of lansoprazole granule not coated with sodium alginate decreased to 57.96% of initial content when stored at a severe condition for 4 weeks, but that of lansoprazole granule coated with sodium alginate before enteric coating decreased little and as the thickness of sodium alginate film increased, the content of bead didn't decreased for 4 weeks. Sodium alginate film also improved the gastroresistance without much influencing the maximum dissolution rate.

Coating behavior of zirconia film fabricated by granule spray in vacuum (상온진공 과립분사에 의한 지르코니아 필름의 코팅거동)

  • Tungalaltamir, Ochirkhuyag;Kang, Young-Lim;Park, Woon-Ik;Park, Dong-Soo;Park, Chan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.5
    • /
    • pp.205-211
    • /
    • 2022
  • The Granule Spray in Vacuum (GSV) process is a method of forming a dense nanostructured ceramic coating film by spraying ceramic granules on a substrate at room temperature in a vacuum. In the Granule Spray, the granules made by agglomerating particles with the size from submicrometer to micrometer can be sprayed into the substrate. Once the granules were squashed upon collision with the substrate, they become several dozens of nanometer-sized crystals in vacuum process. The zirconia of the monoclinic phase transform into tetragonal phase at 1150℃. At this time, its volume is changed by about 6.5 %. For this reason, it is widely held that it is difficult to acquire a compact of monoclinic zirconia sinter. In this study, the effect of particle treatment temperature and standoff distance on the substrate of zirconia granules were investigated in GSV. Also, particle treatment temperature, standoff distance, coating efficiency, and microstructure of the film were considered in forming the monoclinic zirconia coating film in GSV without any heating process. The deposited films exhibited monoclinic zirconia phase without any other detectable phase by X-ray diffractometer (XRD).