• Title/Summary/Keyword: sprA

Search Result 238, Processing Time 0.028 seconds

Analysis of ethanol concentration and refractive-index by use of surface plasmon resonance effect (표면 플라즈몬 공명에 의한 에탄올의 농도 및 굴절률 분석)

  • 도용화;이관수;송석호;손대원;이상선
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • A surface plasmon sensor has been fabricated for detection of concentration and refractive-index of a mixed solution. Based on the Kretschmann-Raether attenuated-total-reflection configuration, the sensor consists of 54 nm-thick Ag metal layer under a prism and a cell containing the mixed solution. We have observed a nonlinear refractive-index change as the ethanol-water concentration increased. The experimental results show us that the detection limit of the SPR sensor is 3$\times$10$^{-2}$ % in ethanol mass ratio. The concentration-to-index curve shows a linear increase in the range of ethanol concentration from 0% to 50%, but a nonlinearity is observed beyond 50%. We have modeled the nonlinearity and compared it with the experimental results.

A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks (랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.23-30
    • /
    • 2016
  • A fire extinguishing system for a rack warehouse was recently designed, which only consider the gross area and number of stories. However, the design of such a system should take into account not only the planar structuree, but also the elevation perspectives due to its vertical structure. Moreover, the fire load of the commodities palletized on the racks should be considered, in order to design a performance-based fire safety system that is appropriate for these environmental conditions. For this reason, this study analyzed the fire characteristics of the commodities palletized on the racks (pallet + the commodities in a box unit + vinyl packing material), taking into consideration the results of a field investigation conducted in Korea, as well as the Hazard Classifications of Commodities used in other countries. Through this analysis, the heat release rate (HRR) and smoke production rate (SPR) were derived.

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.

Study of the optical switching properties in waveguide type Au/$SiO_2$ nanocomposite film using prism coupler (프리즘 커플러를 이용한 도파로형 Au/$SiO_2$ 나노 혼합박막의 광 스위칭 특성 연구)

  • Cho, Sung-Hun;Lee, Soon-Il;Lee, Taek-Sung;Kim, Won-Mok;Lee, Kyeong-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.76-76
    • /
    • 2008
  • The resonance properties due to the surface plasmon(SP) excitation of metal nanoparticles make the nanocomposite films promising for various applications such as optical switching devices. In spite of the well-known ultra-sensitive operation of optical switches based on a guided wave, the application of nanocomposite film(NC) has inherent limitation originating from the excessive optical loss related with the surface plasmon resonance(SPR). In this study, we addressed this problem and present the experimental and theoretical analysis on the pump-probe optical switching in prism-coupled Au(1 vol.%):$SiO_2$ nanocomposite waveguide film. The guided mode was successfully generated using a near infrared probe beam of 1550 nm and modulated with an external pump beam of 532 nm close to the SPR wavelength. We extend our approach to ultra-fast operation using a pulsed laser with 5 ns pulse width. To improve the switching speed through the reduction in thermal loading effect accompanied by the resonant absorption of pump beam light, we adopted a metallic film as a coupling layer instead of low-index dielectric layer between the high-index SF10 prism and NC slab waveguide. We observed great enhancement in switching speed for the case of using metallic coupling layer, and founded a distinct difference in origin of optical nonlinearities induced during switching operation using cw and ns laser.

  • PDF

Output-Feedback Control of Uncertain Nonlinear Systems Using Adaptive Fuzzy Observer with Minimal Dynamic Order

  • Park, Jang-Hyun;Huh, Sung-Hoe;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.39.2-39
    • /
    • 2001
  • This paper describes the design of an output-feedback controller based on an adaptive fuzzy observer for uncertain single-input single-output nonlinear dynamical systems. Especially, we have focused on the realization of minimal dynamic order of the adaptive fuzzy observer. For the purpose, we propose a new method in which no strictly positive real(SPR) condition is needed and combine dynamic rule activation scheme with on-line estimation of fuzzy parameters. By using proposed scheme, we can reduce computation time, storage space, and dynamic order of the adaptive fuzzy observer ...

  • PDF

Development of a Point Tracking System for Measuring Structural Deformations Using Commercial Video Cameras

  • Kim, Hong-Il;Kim, Ho-Young;Park, Hyun-Jin;Han, Jae-Hung;Kim, Jun-Bum;Kim, Do-Hyung;Han, Jeong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.10 no.2
    • /
    • pp.86-94
    • /
    • 2009
  • This paper deals with the creation of a new, low-cost point/position tracking system that can measure deformations in engineering structures with simple commercially widespread cameras. Though point tracking systems do exist today, such as Stereo Pattern Recognition (SPR) and Projection Moir$\acute{e}$ Interferometry (PMI) systems, they are far too costly to use to analyze small, simple structures because complex optical components such as large flashes, high-resolution cameras and data acquisition systems with several computers are required. We developed a point tracking system using commercial cameras. This system used IR LEDs and commercial IR CCD cameras to minimize the interference posed by other extraneous light sources. The main algorithm used for this system is an optical point tracking algorithm, which is composed of the point extraction algorithm and the point matching algorithm for 3-D motion estimation. a series of verification tests were performed. Then, the developed point tracking system was applied to measure deformations of an acrylic plate under a mechanical load. The measured deformations of the acrylic plate matched well with the numerical analysis results. The results indicate that the developed point tracking system is reliable enough to measure continuous deformed shapes of various engineering structures.

Quantitative Assay of Recombinant Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor (Surface plasmon resonance 바이오센서를 이용한 재조합 B형 간염 표면항원의 정량분석)

  • Lee, E. K.;Ahn, S. J.;Yoo, C. H.;Ryu, K.;Jeon, J. Y.;Lee, H. I.;Choi, S. C.;Lee, Y. S.
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • We performed a basic experiment for rapid, on-line, real-time measurement of HBsAg by using a surface plasmon resonance biosensor to quantify the recognition and interaction of biomolecules. We immobilized the anti-HBsAg polyclonal antibody to the dextran layer on a CM5 chip surface which was pre-activated by N-hydroxysuccinimide for amine coupling. The binding of the HBsAg to the immobilized antibody was measured by the mass increase detected by the change in the SPR signal. The binding characteristics between HBsAg and its antibody followed typical monolayer adsorption isotherm. When the entire immobilized antibody was interacted, there was no additional, non-specific binding observed, which suggested the biointeraction was very specific as expected and independent of the ligand density. No significant steric hindrance was observed at 17.6 nm/$mm^2$ immobilization density. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the chip surface was linear up to ca. $40\mu\textrm{g}$/mL, which is much wider than that of the ELISA method. It appeared the antigen-antibody binding was increased as the immobilized ligand density increased, but verification is warranted. This study showed the potential of this biosensor-based method as a rapid, simple, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification replacing the current ELISA method.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

A Novel Anticoagulant Protein with High Affinity to Blood Coagulation Factor Va from Tegillarca granosa

  • Jung, Won-Kyo;Jo, Hee-Yeon;Qian, Zhong-Ji;Jeong, Young-Ju;Park, Sae-Gwang;Choi, Il-Whan;Kim, Se-Kwon
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.832-838
    • /
    • 2007
  • A novel inhibitory protein against blood coagulation factor Va (FVa) was purified from muscle protein of granulated ark (Tegillarca granosa, order Arcoida, marine bivalvia) by consecutive FPLC method using anion exchange and gel permeation chromatography. In the results of ESI-QTOF tandem mass analysis and database research, it was revealed that the purified T. granosa anticoagulant protein (TGAP) has 7.7 kDa of molecular mass and its partial sequence, HTHLQRAPHPNALGYHGK, has a high identity (64%) with serine/threonine kinase derived from Rhodopirellula baltica (order Planctomycetales, marine bacteria). TGAP could potently prolong thrombin time (TT), corresponding to inhibition of thrombin (FIIa) formation. Specific factor inhibitory assay showed that TGAP inhibits FVa among the major components of prothrombinase complex. In vitro assay for direct-binding affinity using surface plasmon resonance (SPR) spectrometer indicated that TGAP could be directly bound with FVa. In addition, the binding affinity of FVa to FII was decreased by addition of TGAP in dose-dependant manner ($IC_{50}$ value = 77.9 nM). These results illustrated that TGAP might interact with a heavy chain of FVa ($FVa_H$) bound to FII in prothrombin complex. The present study elucidated that non-cytotoxic T. granosa anticoagulant protein (TGAP) bound to FVa can prolong blood coagulation time by inhibiting conversion of FII to FIIa in blood coagulation cascade. In addition, TGAP did not significantly (P < 0.05) show fibrinolytic activity and cytotoxicity on venous endothelial cell line (ECV 304).

Temporal variation of magma chemistry in association with extinction of spreading, the fossil Antarctic-Phoenix Ridge, Drake Passage, Antarctica

  • Choe, Won-Hie;Lee, Jong-Ik;Lee, Mi-Jung;Hur, Soon-Do;Jin, Young-Keun
    • 한국지구과학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.136-141
    • /
    • 2005
  • The K Ar ages, whole rock geochemistry and Sr Nd Pb isotopes have been determined for the submarine basalts dredged from the P2 and P3 segments of the Antarctic-Phoenix Ridge (APR), Drake Passage, Antarctica, for better understanding on temporal variation of magma chemistry in association with extinction of seafloor spreading. The fossilized APR is distant from the known hot spots, and consists of older N-MORB prior to extinction of spreading and younger E-MORB after extinction. The older N-MORB (3.5-6.4 Ma) occur in the southeast flank of the P3 segment (PR3) and the younger E-MORB (1.4-3.1 Ma) comprise a huge seamount at the P3 segment (SPR) and a big volcanic edifice at the P2 segment (PR2). The N-type PR3 basalts have higher Mg#, K/Ba, and CaO/Al2O3 and lower Zr/Y, Sr, and Na8.0 with slight enrichment in incompatible elements and almost flat REE patterns. The E-type SPR and PR2 basalts are highly enriched in incompatible elements and LREE. The extinction of spreading occurring at 3.3 Ma seems to have led to a temporal magma oversupply with E-MORB signatures. Geochemical signatures such as Ba/TiO2, Ba/La, and Sm/La suggest heterogeneity of upper mantle and formation of E-MORB by higher contribution of enriched materials to mantle melting, compared to N-MORB environment. E-MORB magmas beneath the APR seem to have been produced by low melting degree (up to 1% or more) at deeper low-temperature regime, where metasomatized veins consisting of pyroxenites have preferentially participated in the melting. The occurrence of E-MORB at the APR is a good example to better understand what kinds of magmatism would occur in association with extinction of spreading.

  • PDF