• Title/Summary/Keyword: spot measurements

Search Result 80, Processing Time 0.026 seconds

A Study on the Sizes of Ready-made Clothes to Export to China - Suggestion of Chinese Correspondent Sizes Based on Korean Women's Clothes - (중국수출(中國輸出) 여성기성복(女性旣成服)의 치수(値數)에 관(關)한 연구(硏究) - 한국(韓國) 여성복(女性服)을 중심(中心)으로 한 중국(中國) 여성복(女性服)의 대응치수(對應値數) 제시(提示)-)

  • Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.8 no.4
    • /
    • pp.1-21
    • /
    • 2004
  • This research suggest the correspondent sizes of female ready-made clothes to export to China on the basis of those of Korean women's ready-made clothes. The following is the concrete coverage of this research: $\cdot$ Analyze the physical measurements and body types of the women in their 30s and 40s in the area of Ningbo, Jeolgang Province in China. $\cdot$ Compare the body measurements of Chinese and Korean women. $\cdot$ Hold compensation measurement by an basic torso pattern test to raise precision of the direct and indirect body measurements. $\cdot$ Establish the corresponding and representative sizes of women's ready-made clothes to go to China. $\cdot$ Make basic torso pattern and sample clothes reflecting representative sizes. $\cdot$ Hold adjustment and compensation through the wearing evaluation by Chinese consumers on the spot. $\cdot$ Finally suggest the correspondent sizes of women's ready-made clothes to export to China.

Study about Prediction Model to Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Nearby High Voltage Power Line (고압 송전선로 주변에 위치한 초등학교 학생들의 극저주파 자기장 노출량 예측 모델에 관한 연구)

  • Kim, Yoon-Shin;Hyun, Youn-Joo;Choi, Seong-Ho;Roh, Young-Man;Hong, Seung-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.506-514
    • /
    • 2006
  • The objectives of this study were to evaluate personal exposure estimated using a time activity pattern and microenvironmental model. The study was carried out for 44 children attending a primary school nearby the lines (school A) and 125 children attending a school away from 154 kV power lines (school B). For children attending school A, the estimated personal level was a little weak correlated with the measured level($Pearson\;r\;=0.34{\sim}0.35$). For children attending school B, the correlation was very low ($Pearson\;r\;=\;0.09{\sim}0.16$) using the TW A Model II, otherwise, TWA Model II-I which considered the average residential MF level according to the distance from the power line and home explained $39{\sim}53%$ of the correlation in MF personal exposures. The estimated personal exposure level was very well represented by the measured exposure level using TWA Model II-2 which consisted on spot and 24 h stationary measurements at subject's home ($Pearson\;r\;=\;0.65{\sim}0.85$). In conclusion, personal magnetic field expsoure estimated using a TWA Model II-2 should be provided for a reasonable estimate of measured exposure in schoolchildren living near the power line.

Application of a Wire code in Domestic Residential EMF Studies (국내 거주환경에서의 전자기장 노출평가를 위한 Wire code의 타당성에 관한 연구)

  • Tak, Sang-Woo;Kim, Hyun;Kim, Rohko
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.55-60
    • /
    • 2000
  • Wire codes, introduced by Wertheimer and Leeper, are interesting largely because several case-control studies have reported associations between them and certain types of cancers, including childhood leukemia. This paper is concerned with the reliability of wire codes as a surrogate for residential electric and magnetic field, divided into four categories based on the electrical wiring within 40m of homes. To examine the correlation between spot measurements and wire codes, EMF was measured by using HI-3604 and classified by wire codes. The correlation between long-transformed RMS of magnetic field and wire codes was 0.81. But the correlation between log-transformed RMS of electric field and wire codes was 0.27. The results led us to determine a four category from of the Wertheimer and Leeper code that 1) may be useful in domestic epidemiological studies and 2) is not suitable for electric field exposure. Thus, the critical point of exposure assessment in residential magnetic field is to classify a wire code precisely.

  • PDF

Precision measurements of radiometric aperture area by laser spot scanning along the edge of the aperture (레이저 스폿의 칼날주사 방법에 의한 복사계 개구 면적의 정밀측정)

  • 강창호;김석원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.258-262
    • /
    • 2004
  • The uncertainty of the detector-based candela scale is limited by the area measurement uncertainty of radiometric apertures. The apertures were fabricated with a diamond-turning machine which trimmed the edge of the apertures as sharply as a knife edge. The positions of the apertures were controlled by a digital feedback algorithm to scan the laser spot with the beam waist less than 5 ${\mu}{\textrm}{m}$. The knife edge scan yielded a set of coordinates on the edges of the aperture. The areas of the apertures were obtained by fitting the coordinates to the ellipses. The relative standard uncertainty of the measurement was estimated to be 8${\times}$10$^{-5}$.

The First Comprehensive Photometric Study of the Neglected Binary System V345 Cassiopeiae

  • Jeong, Min-Ji;Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.213-221
    • /
    • 2013
  • We present the first BVRI CCD photometric observations of V345 Cas made on 22 nights during the observing seasons in 2007-2008. Our light curves, resembling those of EB-type binary stars, are analyzed with the 2003 version of the Wilson-Devinney binary code. The photometric study shows that V345 Cas is a typical semi-detached binary system with the primary star being about ${\Delta}T$ = 2400 K hotter, two times more massive, but only 17% larger than the secondary star being filled with it's Roche-lobe. The orbit has a relatively large inclination of about $88^{\circ}$. A cool spot on the secondary component is modeled to explain a small light curve asymmetry. Absolute dimensions and related radiometric parameters of the eclipsing pair are calculated and their evolutionary states are discussed with the HR diagrams of mass-radius and temperature-luminosity. A period analysis of all available times of minima, including our measurements, indicates that the orbital period may vary in a cyclical way, unfortunately the secondary period for the variation can not be uniquely determined because of lack of present timing data.

Colorimetric evaluation of white spot lesions following external bleaching with fluoridation: An in-vitro study

  • Choi, Yoon-Young;Lee, Dong-Yul;Kim, Yae-Jin
    • The korean journal of orthodontics
    • /
    • v.48 no.6
    • /
    • pp.377-383
    • /
    • 2018
  • Objective: This study was performed to investigate the effects of external tooth bleaching with flouridation on the appearance of white spot lesions (WSLs) in vitro. Methods: In total, 125 bracket-bonded bovine incisor enamel blocks with artificial WSLs were randomly divided into a control group and four treatment groups (home bleaching, home bleaching + fluoridation, in-office bleaching, and in-office bleaching + fluoridation). A spectroradiometer (SR) and digital images (DIs) were used to evaluate colorimetric parameters (Commission Internationale l'Eclairage $L^*a^*b^*$) for all specimens. Color measurements were obtained before WSL formation (T1), after WSL formation (T2), and after completion of the external tooth bleaching treatment (T3). Results: The SRbased color change after bleaching was significantly greater in the treatment groups than in the control group (p < 0.05). SR-based lightness ($L^*$) and redgreen ($a^*$) values were significantly higher at T2 than at T1 (p < 0.001), with no significant changes in yellow-blue ($b^*$) values. At T3, SR-based $L^*$ values had increased while $a^*$ and $b^*$ values had decreased in the treatment groups (p < 0.001). The DI-based color difference between the sound enamel and WSL areas (DE*DI) increased significantly from T1 to T2 in all groups (p < 0.001) and significantly decreased from T2 to T3 in the treatment groups (p < 0.001). No significant differences in ${\Delta}E^*DI$ at T3 were shown between the four treatment groups (p > 0.05). Conclusions: The findings of this study suggested that external tooth bleaching with fluoridation can alleviate the conspicuity of WSLs.

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Comparison of temperature measurements methods to investigate the causes of deformation of packaging materials during microwave heating (전자레인지의 가열조리 시 포장재의 열변형 원인 규명을 위한 온도 측정 방법 비교)

  • Yoon, Chan Suk;Lee, Hwa Shin;Pfeiffer, Thomas;Cho, Ah Reum;Moon, Sang Kwon;Lee, Keun Taik
    • Food Science and Preservation
    • /
    • v.23 no.3
    • /
    • pp.422-431
    • /
    • 2016
  • To investigate the causes of the thermal deformations of packaging materials when microwave-heating ready-to-eat sauce products packaged in stand-up pouches, patterns of temperature changes were determined using an infra-red thermal imaging camera, a thermo-sensitive tape, and a fiver-optic thermometer. The temperature distributions of spicy chicken sauce and Indian curry samples in a stand-up pouch were found to be uneven during micrewave heating. A sharp increase in the temperature was detected, especially above the filling layers and in the corners of sealing layers of the package. The temperature measurements using an infra-red thermal imaging camera are restricted to the surface, and therefore might underestimate the actual temperature. Using a thermo-sensitive tape, temperature up to $200^{\circ}C$ were measured in the spicy chicken sauce sample showing package deformation. When the temperature is measured using a fiber-optic thermometer, it is crucial to have precise sensor performance to accurately measure the temperature in a narrow hot-spot area of the package. In this experiment, the fiber-optic thermometer was attached to a GaAs crystal sensor, which obtained more sensitive and accurate temperature measurements than those by a convectional sensor.

A Study on the Measurements of Optical Parameters in Photosensitizer by Light Scattering (농도가 진한 매질에서 광증감제에 의한 광학적 파라미터측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Joub
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.102-108
    • /
    • 2011
  • The study of wave propagation and scattering in biological media has become increasingly important in recent years. The propagation of light within tissues is an important problem that confronts the dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. In the clinical application of photodynamic therapy(PDT) and in photobiology, the photon deposition within a tissue determines the spatial distribution of photochemical reactions. Scattered light is measured as a function of the distance (r) between the axis of the incident beam and the detection spot. Consequently, knowledge of the photosensitizer(Chlorophyll-a) function that characterizes a phantom is measured. To obtain the results of scattering coefficients(${\mu}s$) of a turbid material from diffusion described by experimental approach. It was measured the energy fluency of photon radiation at the position of penetration depth. From fluorescence experimental method obtained the analytical expression for the scattered light as the values of $(I/I_o)_{wavelength}$ vs the distance between the center of the incident beam and optical fiber in terms of the condition of "in situ spectroscopy(optically thick)" and real time by fluorometric measurements. The result was compromised with transport of intensities though a random distribution of scatters.

A Method for Reducing the Effect of Disk Radial Runout for a High-Speed Optical Disk Drive (고속 광 디스크 드라이브를 위한 디스크의 편심 보상 방법)

  • Ryoo Jung Rae;Moon Jung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.2
    • /
    • pp.101-105
    • /
    • 2006
  • Disk radial runout creates a periodic relative motion between the laser beam spot and tracks formed on an optical disk. While only focus control is activated, the periodic relative motion yields sinusoid-like waves in the tracking error signal, where one cycle of the sinusoid-like waves corresponds to one track. The frequency of the sinusoid-like waves varies depending on the disk rotational speed and the amount of the disk radial runout. If the frequency of the tracking error signal in the off-track state is too high due to large radial runout of the disk, it is not a simple matter to begin track-following control stably. It might take a long time to reach a steady state or tracking control might fail to reach a stable steady state in the worst case. This article proposes a simple method for reducing the relative motion caused by the disk radial runout in the off-track state. The relative motion in the off-track state is effectively reduced by a drive input obtained through measurements of the tracking error signal and simple calculations based on the measurements, which helps reduce the transient response time of the track-following control. The validity of the proposed method is verified through an experiment using an optical disk drive.