• Title/Summary/Keyword: spiral test

Search Result 194, Processing Time 0.024 seconds

Spreading of motion aftereffect for rotational motion: Evidence of adaptation of global motion detector (회전 운동 잔여 효과의 확산 현상: 전역적 운동 탐지기의 순응에 대한 증거)

  • Kham Keetaek
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.1
    • /
    • pp.17-27
    • /
    • 2005
  • After prolonged viewing of a moving pattern, a stationary pattern can appear to move in the opposite direction, a phenomenon known as motion aftereffect (MAE). Unlike the classical explanation MAE was not confined to an adapted region; instead it can spread to an adjacent region, which was not adapted previously. In order to examine the relative locus of the mechanism responsible for MAE spreading, a rotating harmonic spiral pattern was presented as an adapting stimulus within an annulus window, and then the duration of MAE was measured in both the adapted annulus region and the non-adapted inner region. Two different kinds of test patterns were used: the same and mirror images of the original adapting pattern. An interesting characteristic of a harmonic spiral is that the orientation of a contour at a given location is different from thar of its mirror image by 90 degrees, and consequently the adapting effect of local motion detector is not expected to occur in the mirror image. The results showed that MAE duration in an adapted region was longer in the same image condition than in its mirror image condition, while MAE duration in an non-adapted region was not found to be different between those two different image conditions. These results suggest that MAE spreading might be produced by the adaptation of global motion detectors, not by local motion detectors.

  • PDF

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography (자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교)

  • Lee, Kyoung Soo;Kang, Chang Gu;Huh, Ryoong;Lee, Sang Hoon;Chung, Ui Wha
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.6
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF

When Do People Post a Comment to a News Story on the Internet?

  • Lee, Mina;Choi, Inhye;Yang, Seungchan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.434-445
    • /
    • 2015
  • In reading news stories online, people are exposed to others' comments to a news story. In spite of popularity of comments to a news story online, the understanding of why and who posts a comment is still lacking. To complement scarcity and have a better understanding of comment-posting online, this study examined psychological factors which affect the likelihood of posting a comment to a news story online. In particular, three variables were considered: The first variable was communication efficacy, that is, an individual's belief about communication practices and systems, under the supposition that the people who have greater levels of communication efficacy are more likely to post a comment. The second variable was perception of public opinion, to test that when and if people judge their position of the issue as favored by the majority, they tend to post a comment. And finally, the tone of existing comments was included, to test if the tone of comments affects the willingness to post a comment. The results showed that firstly, people at a high level of communication efficacy are more likely to post a comment compared to people at the low level of communication efficacy. Secondly, the perception of public opinion partly influenced the willingness to post a comment. Especially, when people believe communication systems contribute to develop society and also when judged that their opinion is the majority's opinion, they are more likely to post a comment. Finally, the tone of the comments influenced the willingness to post a comment only on the condition that people are confident of the communication practice and are exposed to emotional comments.

Evaluation of Shear Performance of Reinforced Concrete Beams for Varying Reinforcement Details of Web Opening (유공부 보강상세에 따른 철근콘크리트 유공 보의 전단 성능 평가)

  • Kim, Min-Jun;Lee, Bum-Sik;Kim, Dong-Whan;Kim, Hyeong-Gook;Lee, Yong-Jun;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • This study evaluates the shear performance of reinforced concrete members with web opening reinforcement. A total of 4 reinforced concrete members with or without openings were cast then tested. The main variables investigated were with or without of web openings and with or without of web opening reinforcement, respectively. The proposed web opening reinforcement was a rectangle and rhombus-shaped spiral considering of construct ability. Test result showed that the proposed web reinforcement had improved shear capacity and ductility of the specimens. It was found that the web opening reinforcement proposed in this study had a positive effect on the shear strength and crack control of RC beams with web openings. In addition, it was confirmed that the analytical results by the current design codes underestimates the test results of the specimens with the proposed web opening reinforcement.

Study on the Manoeuvring Characteristics of a Ship with Stern Bulb (선미벌브를 갖는 선박의 조종특성에 관한 연구)

  • Kyoung-Ho Sohn;Gyoung-Woo Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.65-79
    • /
    • 1994
  • In the present paper, An emphasis is laid upon effects of stern bulb on hydrodynamic property and manoeuvring performance. We carried out captive model tests in circulating water channel with two ship models of which the frame lines of aft bodies are different. such as normal stern form and stern form with bulb, but of which the other parts are exactly same. The tests conducted consist of hull resistance test, effective thrust measurement, oblique tow test, and measurements of factors related to rudder force. From the results of model tests, we discussed effects of stern bulb on hull forces and on hull-propeller-rudder interactions, comparing with normal stern form. Furthermore, we also discussed effects of stern bulb on course stability. turning ability. spiral characteristics and zig-zag manoeuvre by computer simulation. As a result, it is clarified that the adoption of stern bulb makes course stability the worse and turning ability the better. The difference of the hydrodynamic derivatives of naked hull between two ship forms cause the worse course stability of the ship with stern bulb. The differences of the effective inflow velocity to rudder and hull forces induced by steered rudder cause the better turning ability of the ship with stern bulb.

  • PDF

Experimental research on the behavior of circular SFRC columns reinforced longitudinally by GFRP rebars

  • Iman Saffarian;Gholam Reza Atefatdoost;Seyed Abbas Hosseini;Leila Shahryari
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.513-525
    • /
    • 2023
  • This research presents the experimental and theoretical evaluations on circular steel-fiber-reinforced-concrete (SFRC) columns reinforced by glass-fiber-reinforced-polymer (GFRP) rebar under the axial compressive loading. Test programs were designed to investigate and compare the effect of different parameters on the structural behavior of columns by performing tests. Theses variables included conventional concrete (CC), fiber concrete (FC), steel/GFRP longitudinal rebars, and transversal rebars configurations. A total of 16 specimens were constructed and categorized into four groups in terms of different rebar-concrete configurations, including GFRP-rebar-reinforced-CC columns (GRCC), GFRP-rebar-reinforced-FC columns (GRFC), steel-rebar-reinforced-CC columns (SRCC) and steel-rebar- reinforced-FC columns (SRFC). Experimental observations displayed that failure modes and cracking patterns of four groups of columns were similar, especially in pre-peak branches of load-deflection curves. Although the average ultimate axial load of columns with longitudinal GFRP rebars was obtained by 17.9% less than the average ultimate axial load of columns with longitudinal steel rebars, the average axial ductility index (DI) of them was gained by 10.2% higher than their counterpart columns. Adding steel fibers (SFs) into concrete led to the increases of 7.7% and 6.7% of the axial peak load and the DI of columns than their counterpart columns with CC. The volumetric ratio had greater efficiency on peak loads and DIs of columns than the type of transversal reinforcement. A simple analytical equation was proposed to predict the axial compressive capacity of columns by considering the axial involvement of longitudinal GFRP rebars, volumetric ratio, and steel spiral/hoop rebar. There was a good correlation between test results and predictions of the proposed equation.

Assessment of the proximity between the mandibular third molar and inferior alveolar canal using preoperative 3D-CT to prevent inferior alveolar nerve damage

  • Lee, Byeongmin;Park, Youngju;Ahn, Janghoon;Chun, Jihyun;Park, Suhyun;Kim, Minjin;Jo, Youngserk;Ahn, Somi;Kim, Beulha;Choi, Sungbae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.30.1-30.7
    • /
    • 2015
  • Background: The inferior alveolar nerve (IAN) may be injured during extraction of the mandibular third molar, causing severe postoperative complications. Many methods have been described for evaluating the relative position between the mandibular third molar and the inferior alveolar canal (IAC) on panoramic radiography and computed tomography, but conventional radiography provides limited information on the proximity of these two structures. The present study assessed the benefits of three-dimensional computed tomography (3D-CT) prior to surgical extraction of the mandibular third molar, to prevent IAN damage. Methods: This retrospective study included 4917 extractions in 3555 patients who presented for extraction of the mandibular third molars. The cases were classified into three groups, according to anatomical relationship between the mandibular third molars and the IAC on panoramic radiography and whether 3D-CT was performed. Symptoms of IAN damage were assessed using the touch-recognition test. Data were compared using the chi-square test and Fisher's exact test. Results: Among the 32 cases of IAN damage, 6 cases were included in group I (0.35 %, n = 1735 cases), 23 cases in group II (1.1 %, n = 2063 cases), and 3 cases in group III (0.27 %, n = 1119 cases). The chi-square test showed a significant difference in the incidence of IAN damage between groups I and II. No significant difference was observed between groups I and III using Fisher's exact test. In the 6 cases of IAN damage in group I, the mandibular third molar roots were located lingual relative to the IAC in 3 cases and middle relative to the IAC in 3 cases. The overlap was ${\geq}2mm$ in 3 of 6 cases and 0-2 mm in the remaining 3 cases. The mean distance between the mandibular third molar and IAC was 2.2 mm, the maximum distance 12 mm, and the minimum distance 0.5 mm. Greater than 80 % recovery was observed in 15 of 32 (46.8 %) cases of IAN damage. Conclusions: 3D-CT may be a useful tool for assessing the three-dimensional anatomical relationship and proximity between the mandibular third molar and IAC in order to prevent IAN damage during extraction of mandibular third molars.

A study on the intraoral factor related to oral malodor (구취발생에 관여하는 구강내부요인에 관한 연구)

  • Jung, Mi-Ae;Lee, Eun-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.119-131
    • /
    • 2008
  • This study was peformed in order to find out the relationship between the causing factors and the production of each gas 01 oral malodor, to contribute the oral malodor control at dental clinic as well as to establish the effective application of malodor control project for public oral health program 127 patients from 20 to 40 years old who had been visited for preventive dental cares were participated for the study. Such items as caries status, periodontal status, salivary flow, viscosity, pH. Snyder test, plaque deposit and tongue plaque were checked through the oral examination in order to find out the contributing factors Hydrogen sulfide, Methyl mercaptan, Di-methyl sulfide and Ammonia gas components were checked with Oral-Chroma and Attain, the oral malodor check units. Not only the corelation coefficiencies but also the multi-way variance analysis were calculated between each causing factor and each component of oral malodor gases to estimate the contributing factors of the oral malodor. 1. There was no relationship between the caries status and each component pf the oral malodor such as sulfur compound or Ammonia, both in laboratory test and VAS test (pF0.05). It revealed negative relationship between Hydrogen sulfide and FT(rM-0.1904. pE0.05) as well as the VAS and FT (rM-0.210. pE0.05). S0, it was estimated that the less oral malador was recognized when caries state changed to filled state in Hydrogen sulfide laboratory test or VAS test 2. High relationship was showed between salivary flow and Hydrogen sulfide (rM-0.183, pM0.039), Methyl mercaptan(rM-0.234, p-0.008). Dimethyl sulfide(rM-0.234, pM0.008) and Ammonia(-0.361. pM0.001) gas(pE0.05). 3. There was a high relationship between M-PHP(Modified-Patient Hygiene Performance Index) and tong plaque all kinds of sulfide(rM0.249. pM0.005). Ammonia gas component(rM0.232, pM0.009). 4. It was found that considerable relationship was appeared between the periodontal status and Ammonia gas (rM0.274, pM0.002), so, it should be needed to control Ammonia. Such dental Cares as the prevention or early treatment of periodontal disease and the accelerating the salivary flow as well as reducing the amounts and activities of filament or spiral typed oral micro-organism were recommended for adults, not only for dental care program at the dental clinics but also for public health programs, in order to promote the oral health and quality of file for individual and community peoples.

  • PDF

Effects of Flow Rate of Feed Kanjang and Volume Reduction Ratio of Retentate on the Permeate Flux and Rejection of Microbes Cells and Components in Kanjang during Ultrafiltration Operations (재래식 간장의 한외여과시 공급액의 주입속도와 잔류액의 용량감소율이 간장의 투과유속, 미생물균체 및 성분저지율에 미치는 영향)

  • Kwon, Kwang-Il;Lee, Jong-Gu;Choi, Jong-Dong;Chung, Hyun-Chae;Im, Moo-Hyeog;Kim, Ki-Ju;Kim, Woo-Seong;Sung, Jun-Hyun;Kwon, O-Jun;Kim, Young-Ji;Suh, Chung-Sik;Choi, Cheong;Choi, Kwang-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.72-76
    • /
    • 2003
  • Ultrafiltration (UF) tests performed on traditional soy sauce (kanjang) using UF flat membrane test cell unit with thin film laminar flow similar to the spiral type membrane module in batch operations revealed reduction in permeate flux is proportional to the logarithm values of volume reduction ratio of the retentate kanjang at different feed rate of kanjang. Feed rate of 1.5 L/min was found to be adequate for long-term UF operation of kanjang using the test unit attached with MW cut-off size of 200,000 dalton polyoleffin plastic membrane in batch operation with the least concentration polarization. The higher the feed rate of kanjang, the lower the permeability of total nitrogen and NaCl, resulting in lower optical density at 500 nm and lower permeability of minerals such as Cu, Mn, and Mg. Microbial cells were completely rejected regardless of the feed rate, whereas most free amino acids were not.