• Title/Summary/Keyword: spiral antenna

Search Result 85, Processing Time 0.02 seconds

Analysis of Direction Finding Accuracy for Amplitude-Phase Comparison and Correlative Interferometer Method (진폭-위상 복합비교 기법과 상관형 위상비교 기법의 방향탐지 정확도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2016
  • In this paper, we present the direction finding accuracy of correlative interferometer method and amplitude-phase comparison method. Spiral antennas are used for amplitude-phase comparison method and blade antennas are used for correlative interferometer method. Those are made for uniform circular array (UCA) direction finding antenna systems. We simulate the accuracy of azimuth angle with 3 antennas UCA when SNR is 20 dB and baseline is 0.5 wave length. Correlative interferometer method has better accuracy than amplitude-phase comparison method.

A study on the UHF PD measuring technique for GIS with a metal flange around insulating spacer (스페이서에 Metal flange가 있는 GIS에서의 UHF PD 측정 기술 연구)

  • Kang, W.J.;Lee, C.J.;Kang, Y.S.;Park, J.B.;Lee, H.C.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1638-1640
    • /
    • 2003
  • In the recent years, UHF PD measuring technique for detecting partial discharges was proved the effective method for Gas Insulated Switchgear (GIS). However, in case of GIS with a metal flange around insulating spacer, UHF PD measurement using typical external UHF PD sensor is difficult. In this paper, a novel hole-type UHF PD sensor based on Archimedean spiral antenna theory has been proposed and realized. All spacers with metal flange have small hole in order to inject epoxy. Using the novel hole-type UHF PD sensor, it makes detection possible to PD signal that are emitted through the epoxy injection hole. Additionally, the measuring characteristic of UHF PD signals from several artificial defects in GIS and the novel ${\Phi}$-f-q pattern analysis technology are discussed.

  • PDF

Size Reduction of a Quasi Class-E High Power Amplifier Using Defected Ground Structure (결함 접지 구조를 이용한 유사 E급 전력 증폭기의 소형화)

  • Choi, Heung-Jae;Jeong, Yong-Chae;Lim, Jong-Sik;Jung, Young-Bae;Eom, Soon-Young;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this work, a reduced size 20W quasi class-E Power Amplifier(PA) with defected ground structure load-network is presented for WCDMA base station application. Harmonic impedances required for the class E operation are satisfied by applying the dumbbell and the asymmetric spiral DGS. Open impedance for 2nd harmonic frequency which has the highest power and nearly short impedances for other higher order harmonics are provided by the proposed DGS load-network. The maximum Power Added Efficiency(PAE) of 70.2 % at the output power of 43.1 dBm with the saturated power gain of 12.7 dB is achieved by the proposed quasi class-E PA, which is comparable to the performance of the reference class-E PA. Total size of the proposed class-E PA is only $50{\times}50\;mm^2$ and much smaller than the conventional class-E PA that is loaded with a number of open stubs.

Dry Etching of Pt/RuO$_{2}$ for Pb(Zr,Ti)O$_{3}$ by High Density Plasma (고밀도 플라즈마를 이용한 PZT용 Pt/RuO$_{2}$ 이중박막의 식각)

  • Lee, Jong-Geun;Park, Se-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • Inductively coupled plasma (ICP) excited by a spiral planar antenna is used to etch elctrodes for PZT capacitors. Pt/RuO$_{2}$ bilayers are tested as bottom electrodes for PZT capacitors in order to utilize better leakage characteristics of Pt and easy etch characteristics of RuO$_{2}$ at the same time. The etch rates and selectivities to SiO$_{2}$ hard mask have been measured for each of Pt and RuO$_{2}$ in terms of various plasma conditions. As Cl$_{2}$ ratio increases in $O_{2}$/Cl$_{2}$ mixture, the etch rate of Pt increases while that of RuO$_{2}$ reaches the highest near 10 % of Cl$_{2}$. Optimum gas mixture ratio has been determined for etching Pt and RuO$_{2}$ bilayers sequentially, and sub-half micron patterning is demonstrated.

  • PDF

Impact of the human body in wireless propagation of medical implants for tumor detection

  • Morocho-Cayamcela, Manuel Eugenio;Kim, Myung-Sik;Lim, Wansu
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.19-26
    • /
    • 2020
  • This paper analyses the feasibility of using implantable antennas to detect and monitor tumors. We analyze this setting according to the wireless propagation loss and signal fading produced by human bodies and their environment in an indoor scenario. The study is based on the ITU-R propagation recommendations and prediction models for the planning of indoor radio communication systems and radio local area networks in the frequency range of 300 MHz to 100 GHz. We conduct primary estimations on 915 MHz and 2.4 GHz operating frequencies. The path loss presented in most short-range wireless implant devices does not take into account the human body as a channel itself, which causes additional losses to wireless designs. In this paper, we examine the propagation through the human body, including losses taken from bones, muscles, fat, and clothes, which results in a more accurate characterization and estimation of the channel. The results obtained from our simulation indicates a variation of the return loss of the spiral antenna when a tumor is located near the implant. This knowledge can be applied in medical detection, and monitoring of early tumors, by analyzing the electromagnetic field behavior of the implant. The tumor was modeled under CST Microwave Studio, using Wisconsin Diagnosis Breast Cancer Dataset. Features like the radius, texture, perimeter, area, and smoothness of the tumor are included along with their label data to determine whether the external shape has malignant or benign physiognomies. An explanation of the feasibility of the system deployment and technical recommendations to avoid interference is also described.