• 제목/요약/키워드: spine SBRT

검색결과 11건 처리시간 0.037초

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

이중 표적 척추 전이암의 체부정위방사선치료 시 Halcyon LINAC의 치료 유용성 평가 (Feasibility study of using Halcyon LINAC for Double-target spine stereotactic body radiation therapy)

  • 정희주;안예찬;박병석;박명환;박용철
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.51-60
    • /
    • 2022
  • 목 적: 이중 표적 척추 전이암의 체부정위방사선치료 시 Halcyon 선형가속기의 용적변조회전치료 계획의 질 및 전달 효율을 평가하고자 한다. 대상 및 방법: 본원의 이중 표적 척추 전이암 환자 12명을 선정하여 Dual Layer MLC를 장착한 Halcyon®과 High Definition MLC를 장착한 Truebeam® 을 이용하여 단일치료중심 척추 SBRT 계획을 수립하였다. 모든 치료 계획은 Eclipse를 이용하여 동일한 조건 및 최적화 과정을 통해 생성하였으며, 치료계획 비교를 위해 C.I, H.I, G.I(Gradient Index), 척수 선량 및 저선량 영역을 평가하고, 전체 MU를 비교하였다. 또한 BOT(Beam On Time)를 측정하여 치료 시간을 비교하였다. 결 과: C.I 와 H.I에서는 통계적으로 유의한 차이는 보이지 않았다. 다만, G.I의 평균은 Halcyon이 4.64으로 Truebeam에 비해 5.5%로 감소하였으며(P<0.001), Halcyon의 50% 및 25% isodose volume 평균은 각각 487.56 cc (-3.82%, P<0.001), 1859.45 cc (-4.75%, P<0.001) 으로 Truebeam보다 축소된 용적을 보였다. 또한 척수 선량 평가에서는 Overlap volume이 1 cc이하인 표본집단에서 Halcyon의 평균 선량 및 V10의 평균은 6.802 Gy (-3.504%, P=0.067), 5.766±1.683 cc (-8.199%, P=0.002)으로 Truebeam보다 낮았다. MU와 각 장비의 최대선량률을 사용한 BOT는 Halcyon에서 증가했으나, 동일한 선량률로 조사 시 Halcyon의 평균은 648.33 sec (-1.74%, P<0.001)으로 단축되었다. 결 론: 이중 표적 척추 전이암의 SBRT 시 Halcyon의 치료 계획은 Truebeam의 치료 계획과 유사한 타겟 내선량 분포 및 척수 보호효과를 가지면서, 가파른 선량 기울기로 저선량 영역에서 이점을 보였다. 이를 통해 이중 표적 척추 전이암 SBRT 시 Halcyon의 적용은 선량학적으로 향상된 치료계획을 제공함을 알 수 있다.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가 (Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator)

  • 임지혜;장남준;석진용;정윤주;원희수;정해윤;최병돈
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.129-138
    • /
    • 2018
  • 목 적 : 임상적으로 많이 시행하는 치료부위에 고차원 치료기법 적용 시 선형가속기에 장착된 다엽콜리메이터(Multi leaf collimator, MLC)의 형태가 치료계획에 미치는 영향을 연구해 보고자 한다. 대상 및 방법 : 본원에서 척추암, 폐암 정위적체부방사선치료(Stereotactic body radiation therapy, SBRT)를 받은 환자와 전립선암, 폐암, 두경부암, 전골반암, 유방암의 용적변조회전치료(Volumetric modulated arc therapy, VMAT)를 시행한 환자들을 부위별로 10명씩 총 70명 선정하였다. Truebeam STx(Varian Medical system, Palo Alto, CA)의 high definition MLC(HD MLC)와 Vitalbeam(Varian Medical system, Palo Alto, CA)에 장착된 millenium MLC(M MLC)를 사용하였고, 치료계획은 Eclipse(Version 13.7, Varian Palo Alto USA, CA)를 이용하여 동일한 조건으로 환자마다 각각 2개씩 수립하였다. MLC의 형태에 따른 치료계획을 평가하기 위해 PTV coverage, conformity index(CI), homogeneity index(HI)를 비교하였고, 정상조직은 각 부위별로 임상에서 사용하는 평가 지표를 분석하였으며, 정상조직에서 저 선량 영역을 비교하기 위하여 $V_{30%}$을 평가하였다. 추가적으로 각 부위별로 치료표적의 길이 및 체적을 조사하였다. 결 과 : PTV coverage는 HD MLC를 적용한 폐암 SBRT에서 평균선량이 0.52 %, 척추암 SBRT에서 평균 선량과 최대선량이 각각 0.68 %, 1.13 %로 M MLC에 비해 감소하였다. CI와 HI는 척추암 SBRT 치료계획에서 HD MLC가 1.144, 1.079로 M MLC의 1.160, 1.092 보다 낮은 수치를 나타냈다(p<0.05). 결정장기의 선량 평가는 폐암 SBRT 치료계획에서 치료받는 쪽 폐의 평균선량이 HD MLC에서 1.48 %로 낮아졌다. 전립선암 VMAT은 HD MLC를 적용한 치료계획에서 방광의 $V_{30}$과 평균선량이 0.53 %, 1.42 %, 직장의 $V_{25}$와 평균선량이 0.97 %, 0.69 %로 감소하였다(p<0.05). 유방암 VMAT은 오히려 HD MLC를 사용한 치료계획에서 심장의 평균선량이 0.83 %로 높아졌다. 다른 치료부위 평가지표들은 두 MLC를 적용한 치료계획 사이에 큰 차이를 보이지 않았다(p>0.05). 결 론 : 본 연구 결과 SBRT나 전립선암 VMAT과 같이 치료표적의 길이가 짧고 크기가 작은 경우 HD MLC를 사용하는 것이 PTV coverage 및 정상조직 보호 효과 면에서 다소 이점이 있는 것으로 나타났으나, 그 외 상대적으로 길고, 큰 폐암, 두경부암, 전골반암, 유방암 VMAT에서는 MLC의 형태가 치료계획에 미치는 영향은 크지 않았다.

  • PDF

CBCT와 EXACTRAC을 이용한 Spine SBRT의 유용성 평가 (A Study to Evaluate the Efficacy of CBCT and EXACTRAC on Spine Stereotactic Body Radiation Therapy)

  • 최우근;박수연;박도근;송기원
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.167-173
    • /
    • 2013
  • 목 적: CBCT와 EXACTRAC을 이용한 Spine 체부정위적방사선 치료 Set up 시 이미지 보정 값과 실제 오차의 차이를 측정하고, 이 오차 값이 미치는 선량분포를 계산하여 CBCT와 EXACTRAC의 유용성을 평가하고자 한다. 대상 및 방법: Set up 오차 보정 값과 실제 오차 비교 실험을 위해서 QA용 Cubic phantom (The EASY CUBEr, Euromechanics, Schwarzenbruck, Germany)을 이용하였고, phantom의 중심축을 인위적으로 LR 방향으로 -1 mm, -2 mm, -3 mm SI 방향으로 1 mm, 2 mm, 3 mm 그리고 AP방향으로 1 mm, 2 mm, 3 mm 이동시켰으며, 중심축을 $0.5^{\circ}$씩 좌우로 회전시켜 CBCT와 EXACTRAC의 Auto matching 보정 값과 비교 측정하였으며, 이동된 오차 값을 가정하여 Rando Phantom을 이용한 Spine SBRT 플랜에 적용하여 재계산을 시행하였다. 결 과: Set up 보정 값과 실제 오차 비교실험에서 3D CBCT의 평균값은 LR, SI, AP 방향으로 0.15 mm 회전방향으로 $0.04^{\circ}$였고 EXACTRAC의 평균값은 LR, SI, AP 방향으로 0.18 mm 회전방향으로 $0.07^{\circ}$였다. 이동 값 오차를 가정한 선량 재계산 결과, SI방향 2, 3 mm 이동 시 $V_{10}$ (종양의 용적에 10 Gy가 들어가는 선량) Volume이 각각 10.574%, 10.712%가 나타났고 LR방향 -3 mm 이동 시 12.076%로 가장 높게 나타났다. 결 론: CBCT와 EXACTRAC의 Set up 보정 값과 실제 오차는 1 mm, $0.1^{\circ}$ 미만으로 두 시스템 모두 매우 정밀한 set up 오차보정을 보였다. 그러나 선량 재계산 시 3 mm 이상의 오차가 발생한 경우, Spine SBRT 치료 시 Spinal cord에 들어가는 선량이 $V_{10}$에서 3% 이상 최대선량 13 Gy 이상 증가함으로서 치명적인 흡수선량 오류가 발생할 수 있음을 확인하였다. 따라서 본 저자는 1회에 한한 Spine SBRT 치료 시 정확도 측면에서 종양의 단면 정보를 위치적으로 제공하는 CBCT가 더 유용할 것으로 사료된다.

  • PDF

Contemporary treatment with radiosurgery for spine metastasis and spinal cord compression in 2015

  • Ryu, Samuel;Yoon, Hannah;Stessin, Alexander;Gutman, Fred;Rosiello, Arthur;Davis, Raphael
    • Radiation Oncology Journal
    • /
    • 제33권1호
    • /
    • pp.1-11
    • /
    • 2015
  • With the progress of image-guided localization, body immobilization system, and computerized delivery of intensity-modulated radiation delivery, it became possible to perform spine radiosurgery. The next question is how to translate the high technology treatment to the clinical application. Clinical trials have been performed to demonstrate the feasibility of spine radiosurgery and efficacy of the treatment in the setting of spine metastasis, leading to the randomized trials by a cooperative group. Radiosurgery has also demonstrated its efficacy to decompress the spinal cord compression in selected group of patients. The experience indicates that spine radiosurgery has a potential to change the clinical practice in the management of spine metastasis and spinal cord compression.

Spine SBRT 치료시 Coaxial MLC VMAT plan의 유용성 평가 (Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT)

  • 손상준;문준기;김대호;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.313-320
    • /
    • 2014
  • 목 적 : Spine SBRT 치료 시 보편적인 치료방법인 콜리메이터 각도 $30^{\circ}$$330^{\circ}$를 각각 사용한 2회전 치료계획 (이하 Universal MLC VMAT)과 MLC 운동 방향과 척수 또는 마미 (이하 OAR)의 장축을 일치시킨 콜리메이터 각도 $273^{\circ}$$350^{\circ}$를 사용한 2회전 치료계획 (이하 Coaxial MLC VMAT) 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 Varian TBX을 이용하여, Coaxial MLC VMAT 치료 계획으로 치료 받은 spine SBRT환자 10명을 대상으로 하였다. 전산화치료계획은 Eclipse (ver 10.0.42, Varian, USA), PRO3 (Progressive Resolution Optimizer 10.0.28), AAA (Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 이용하였다. 치료계획은 VMAT로 겐트리 회전반경이 각각 $360^{\circ}$인 두 개의 ARC, 10MV FFF (Flattening Filter Free)를 이용하여 수립하였고, 각 ARC는 콜리메이터 각도 $273^{\circ}$, $350^{\circ}$로 설정하였다. 기존 치료계획을 바탕으로 실험군인 Universal MLC VMAT 치료계획을 수립하였다. 콜리메이터 각도를 제외한 모든 조건은 동일하게 설정하였으며, 특히 최적화 (VMAT optimization) 과정에서 무작위하게 나타나는 선량차이를 최소화하기 위해 각각 2회의 최적화, 선량 계산 과정을 거쳤다. 계산 grid 는 0.2 cm, normalization은 타겟 $V_{100%}=90%$로 설정하였다. OAR의 선량 $V_{10Gy}$, $D_{0.03cc}$, Dmean, 타겟의 H.I (Homogeneity index) 그리고 각 치료 계획의 Total MU를 평가 지표로 설정하였고, Mapcheck2 (Sun Nuclear Co., USA) 와 Mapphan (Sun Nuclear Co., USA) 그리고 SNC patient (Sun Nuclear Co., USA Ver 6.1.2.18513) 를 이용하여 Coaxial MLC VMAT 계획의 임상 적용 가능 여부 확인을 위한 IMRT verification QA (gamma test)를 실시하였다. 결 과 : 두 치료계획을 비교한 결과 OAR의 $V_{10Gy}$차이는 최대 4.1%, 최소 0.4%, 평균 1.9%로, $D_{0.03cc}$ 는 최대 83.5 cGy, 최소 2.2 cGy, 평균 33.3 cGy로 Coaxial MLC VMAT plan 이 더 낮은 것으로 나타났다. Dmean 또한 최대 34.8 cGy, 최소 -13.0 cGy, 평균 9.6 cGy로 Coaxial MLC VMAT plan 이 낮은 것으로 나타났다. H.I. 는 최대 0.04, 최소 0.01로 Coaxial MLC VMAT plan 이 평균 0.02 낮은 것으로 나타났으며, Total MU의 평균값을 비교한 결과 Coaxial MLC VMAT plan 이 평균 74.1 MU 더 낮게 나타났다. Coaxial MLC VMAT plan에 대한 IMRT verification gamma test 결과는 1 mm / 2%, pass rate 90.0% 기준을 모두 통과하였다. 결 론 : Coaxial MLC VMAT 치료계획은 Universal MLC VMAT 치료계획에 비해 대부분의 평가지표에서 유리한 것으로 나타냈으며 특히 OAR의 선량 $V_{10Gy}$을 낮추는데 있어 탁월한 것으로 사료된다. 실험결과를 바탕으로 두 치료 계획을 비교해 볼 때, 같은 MU를 사용한다면 Coaxial MLC VMAT 치료계획이 Universal MLC VMAT 치료계획에 비해 효율적이라 사료된다.

International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구 (Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines)

  • 오세안;강민규;김성규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.145-153
    • /
    • 2013
  • 정위적 체부 방사선치료(Stereotactic Body Radiation Therapy, SBRT)는 척추 전이암을 치료하는데 있어서 점점 증가하고 있다. 표적 종양의 급격한 선량 변화와 등선량 분포를 얻기 위해서, 세기조절방사선치료(Intensity-modulated radiation therapy, IMRT)와 체적변조회전치료(Volumetric-modulated arc therapy, VMAT)는 척추 방사선수술에 있어서 필수적인 치료기법이다. 이 연구의 목적은 표적 종양을 위한 International Spine Radiosurgery (ISRC) Consortium의 consensus guideline으로 그려진 표적에 있어서 IMRT와 VMAT의 치료기법을 질적으로 비교하고자 한다. 경부, 흉부, 요추 부위에 종양치료를 받은 3명의 환자를 선택 하였다. 표적 종양은 ISRC의 consensus guideline을 바탕으로 정의 하였다. $T_B$는 vertebral body만 포함하였고, $T_{BPT}$는 vertebral body, pedicle, transverse process를 포함하였다. 그리고 $T_{ST}$는 spinous process와 transverse process를 포함하여 그렸다. Maximum spinal cord선량은 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 12.46 Gy, 12.17 Gy, 11.36 Gy였고, IMRT, RA1, RA2에서 각각 11.81 Gy, 12.19 Gy, 11.99 Gy였다. 평균 감소(90%~50%) 선량 거리 (mm)는 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 3.5 mm, 3.3 mm, 3.9 mm였고, IMRT, RA1, RA2에서 각각 3.7 mm, 3.7 mm, 3.3 mm였다. 가장 복잡한 $T_{BPT}$의 경우에서 IMRT, RA1, RA2의 conformity index는 각각 0.621, 0.761, 0.817 이었고, rDHI는 0.755, 0.796, 0.824 였다. IMRT와 VMAT 모두 척추 정위적 방사선수술에서 표적 종양에 급격한 선량 변화와 등선량 분포를 전달하였다. 그러나 표적 종양이 vertebral body, pedicle, transverse process를 포함한다면, IMRT 치료기법은 VMAT 치료기법과 비교해서 conformity index 측면에서 불충분하였다. 그럼에도 불구하고, IMRT 치료기법은 RA1, RA2와 비교해서 대부분의 영역에서 maximum spinal cord 선량을 줄이는데 더 효과적이었다.

사이버나이프 6-D Skull Tracking의 유용성 평가 (The variability of 6-D Skull Tracking(6DST) in Cyberknife for Bone metastasis patients)

  • 이건호;배선명;송흥권;백금문
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.41-47
    • /
    • 2018
  • 목 적 : 사이버나이프(Accuray Inc., Sunnyvale, CA)를 이용한 제1, 2경추의 정위체부방사선치료(Stereotactic Body Radiation Therapy, SBRT)시 사용가능한 Xsight Spine Tracking(XST)과 6-Dimensional Skull Tracking(6DST)의 비교를 통해 6DST의 유용성을 평가하고자 한다. 대상 및 방법 : 2017년 1월부터 9월까지 본원에서 사이버나이프를 이용하여 제1, 2경추에 SBRT를 진행한 환자 9명을 대상으로, 전산화단층촬영장치(Lightspeed VCT 64, General Electric Co. Waukesha, WI, USA)를 이용해서 컴퓨터 단층 영상(Computed tomography) 을 획득한 후 전산화치료계획시스템(Multiplan system Version 4.6, Accuray, US)를 이용해 제 1, 2경추에 대한 XST와 6DST가 가능한 계획을 수립하였다. 1차 영상 유도를 통해 환자 자세를 보정한 후 동일 환자에 대한 XST와 6DST를 순서대로 진행하고 측정된 결과값을 비교 평가하였다. 결 과 : 제1경추를 대상으로 XST을 실시한 후 측정된 6D Couch 의 Y, Z, X 축 값과 Roll, Pitch, Yaw 값 중 최대값은 0.9 mm, 0.9 mm, 0.7 mm과 $1.0^{\circ}$, $1.0^{\circ}$, $1.2^{\circ}$로 측정되었고, 6DST의 경우 0.7 mm, 0.7 mm, 0.9 mm과 $0.5^{\circ}$, $0.9^{\circ}$, $0.8^{\circ}$로 측정되었다. 제2경추의 XST를 실시했을 때 측정된 값 중 최대값은 0.7 mm, 0.7 mm, 0.8 mm과 $0.9^{\circ}$, $1.0^{\circ}$, $1.8^{\circ}$였고, 6DST의 경우 0.9 mm, 0.7 mm, 0.9 mm와 $0.9^{\circ}$, $0.9^{\circ}$, $1.0^{\circ}$로 측정되었다. 결 론 : 이번 연구를 통해서 제 1, 2 경추에 대한 XST와 6DST의 6D Couch 측정값이 모두 본원에서 기준으로 하고 있는 범위 안에서 측정되고 있음을 확인할 수 있었다. 또한 두 방법을 진행하는 과정에서 설정값 변경을 진행해야하는 XST보다 6DST가 영상유도절차를 간소화 시킬 수 있다는 것을 확인할 수 있었다. 따라서 제 1, 2 경추에 대한 SBRT를 진행할 경우 XST와 더불어서 6DST를 사용한다면 정확한 치료와 더불어서 치료 시간을 단축시킬 수 있을 것으로 사료된다.

  • PDF

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.