Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2003.05d
/
pp.33-37
/
2003
Endovaginal and endorectal receiver only surface coil were designed for MR imaging(MRI) and $^1H$ MR spectroscopy(MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round comer. The shape of endorectal coil wire was long elliptic shape during insertion and circular shape after insertion. Conventional spin echo and fast spin echo sequences were used as T1 and T2 weighted imaging sequences, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method. Using home-built endvaginal and endorectal coils, excellent T1 and T2 images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo $^1H$ MRS was useful to differentiate the cancerous tissue from the normal tissue.
Park, Jinwoo;Daewon Sohn;Lee, Youngil;Chaejoon Cheong
Macromolecular Research
/
v.11
no.6
/
pp.444-450
/
2003
Hydrophobically End-capped polyethylene oxide Urethane Resin(HEUR)-associating polymers, HEUR 35(8), HEUR 35(12), and HEUR 35(18), comprise a polyethylene oxide (PEO) having a molecular weight of 35,000 that is end capped with two C$\_$8/H$\_$17/, C$\_$12/H$\_$25/, and C$\_$18/H$\_$37/ alkyl chains, respectively. These associating polymers were synthesized by condensation reactions with polyethylene oxides and alkyl isocyanates. The self-diffusion coefficients of HEUR-associating polymers were measured in aqueous solution by pulsed-gradient spin-echo (PGSE) nuclear magnetic resonance (NMR) spectroscopy. All polymers underwent a decrease in their mean diffusion coefficients as the concentration was increased. However, the dispersion of the diffusion coefficients, ${\beta}$, about the mean fluctuated with changes in concentration. The large dispersion at low concentrations of HEUR 35(8) and HEUR 35(12) is related to the interaction between hydrophobic end groups, and the large dispersion at high concentrations of HEUR 35(18) is correlated with transient network formation. These results are valuable for predicting the associating mechanism of the large aggregates before and after their critical micelle concentration.
Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.
Purpose : To evaluate the detection rate of hyperacute intracerebral hemorrhage in echo planar imaging (EPI) and other MR sequences. materials and Methods : Intracerebral hemorrhage was experimentally induced in ten rats. EPI, fast spin-echo (FSE) T2 weighted images, fluid attenuated inversion recovery (FLAIR), spin-echo (SE) T1 weighted images and gradient echo (GE) T1 weight ed images of rat's brains were obtained 2 hours after onset of intracerebral hemorrhage. EPI and FSE T2 images were additionally obtained 30 min and 1 hour after onset of hemorrhage in 3 and 6 rat, repeatedly, For objective visual assessment, discrimination between the lesion and normal brain parenchyma was evaluated on various MR sequences by three radiologists. For quantitative assessment, contrast-to-noise ratio (CNR) was calculated fro hemorrhage-normal brain parenchyma. Statistical analysis was performed usning the Wilcoxon-Ranks test. Results : EPI, FLAIR, and FSE T2 images showed high signal intensity lesions. The lesion discrimination was easier on EPI than on other sequences, and also EPI showed higher signal intensity for the subjective visual assessment. In quantitative evaluation, CNR of the hemorrhagic lesion versus normal brain parenchyma were higher on EPI and FLAIR images (p<0.01). There was no difference in CNR between EPI and FLAIR (p>0.10). On MR images obtained 30 minutes and 1 hour after the onset of intracerebral hemorrhage, the lesion detection was feasible on both EPI and FSE T2 images showing high signal intensity. Conclusion : EPI showed higher detection rate as compared with other MR sequences and could be useful in early detection and evaluation of intracerebral hemorrhage.
Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.
Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.
To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.
Vanadium-incorporated aluminophosphate microporous molecular sieve VH-SAPO-42 has been studied by electron spin resonance(ESR) and electron spin-echo modulation (ESEM) spectroscopies to determine the vanadium location and interaction with various adsorbate molecules. The results are interpreted in terms of V(IV) ion location and coordination geometry. Assynthesized VH-SAPO-42 contains only vanadyl species with distorted octahedral or trigonal bipyramidal coordination. Vanadium incorporated into H-SAPO-42 occupied extra-framework site. After calcinations in $O_2$ and exposure to moisture, only species A is observed with reduced intensities. Species A is identified as a $VO(H_2O)_2^{2+}$ complex coordinated to three framework oxygen atoms bonded to aluminum. When hydrated VH-SAPO-42 is dehydrated at elevated temperature by calcination, species A loses its water ligand and transforms to $VO^{2+}$ ions coordinated to three framework oxygens (species B). Species B reduces its intensities significantly after treatment with $O_2$ at high temperature, thus suggesting oxidation of $V^{4+}$ to $V^{5+}$. When dehydrated VH-SAPO-42 makes contact with $D_2O$ at room temperature, the ESR signal of species A is regained. The species is assumed as a $VO(O_f)_3(D_2O)_2$ by considering three framework oxygens. Adsorption of deuterated methanol on dehydrated VH-SAPO-42 results in another new vanadium species D, which is identified as a $VO(CD_3OH)_2$ complex. When deuterated ethylene is adsorbed on dehydrated VH-SAPO-42, another new vanadium species E identified as a $VO(C_2D_4)^{2+}$, is observed. Possible coordination geometries of these various complexes are discussed.
Purpose: The purpose of this study was to evaluate the usefulness of fast inversion recovery (FIR) and magnetization-prepared three dimensional gradient echo sequence (3D GRE) T1-weighted sequences for neonatal brain imaging compared with spin echo (SE) sequence in a 3T MR unit. Materials and Methods: T1-weighted axial SE, FIR and 3D GRE sequences were evaluated from 3T brain MR imaging in 20 neonates. The signal-to-noise ratio (SNR) of different tissues was measured and contrast-to-noise ratios (CNR) were determined and compared in each of the sequences. Visual analysis was carried out by grading gray-white matter differentiation, myelination, and artifacts. The Wilcoxon signed ranked test was used for evaluation of the statistical significance of CNR differences between the sequences. Results: Among the three sequences, the 3D GRE had the best SNRs. CNRs obtained with FIR and 3D GRE were statistically superior to those obtained with SE; these CNRs were better on the 3D GRE compared to the FIR. Gray to white matter differentiation and myelination were better delineated on the FIR and 3D GRE than the SE. However, motion artifacts were more commonly observed on the 3D GRE and flow-related artifacts of vessels were frequently seen on the FIR. Conclusion: FIR and 3D GRE are valuable alternative T1-weighted sequences to conventional SE imaging of the neonatal brain at 3T providing superior image quality.
목적: 최근 들어 컴퓨터 그래픽의 발전과 함께 가상 현실 등에 연구 및 응용이 급증하고 있다. 본 연구의 목적은 fMRI를 이용하여 이차원 및 삼차원 시각자극에 대한 뇌의 기능을 살펴보는 것이다. 같은 영상에 대한 2D와 3D영상을 보여 주면서, fMRI 영상 데이터를 얻었다. 사람에게 미치는 자극 중에 하나인 시각 자극에서 2D와 3D에 대해 반응하는 차이를 규명하고자 하였다. 대상 및 방법: Gradient echo를 기반으로 한 EPI 영상기법을 이용하여, 가톨릭 의대의 3.0 Tesla whole body MRI system에서 실험하였다. 해부학적 영상을 얻기 위해서는 spin echo를 이용하였다. 4명의 volunteer에 대해 같은 영상에 대한 2D와 3D영상을 보여주면서 실험을 수행하였다. 시각자극의 paradigm은 5단계 (rest, active, rest, active, rest)로 하였고, 3번의 rest와 2번의 active구간을 사이에 두었다. 각각의 구간은 10번의 iteration으로 이루어져 있고, 첫 번째 구간은 15번으로 하여 처음 5개의 결과를 버리고, 데이터를 얻었다. 결과는 spm99를 이용하여 분석하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.