• 제목/요약/키워드: spin echo

검색결과 223건 처리시간 0.031초

Cupric Ion Species in Cu(II)-Exchanged Mesoporous MCM-41 Gallosilicate Determined by Electron Spin Resonance Studies

  • Kim, Jeong-Yeon;Yu, Jong-Sung
    • 한국자기공명학회논문지
    • /
    • 제1권2호
    • /
    • pp.126-140
    • /
    • 1997
  • Mesoporous MCM-41 gallosilicate material was synthesized through shifting through shifting gallosilicate polymer equilibrium towards a MCM-41 phase by addition of acid. The location of Cu(II) exchanged into MCM-41 and its interaction with various adsorbate molecules were investigated by electron spin responance and electron spin echo modulation spectroscopies. It was found that in the fresh hydrated material, Cu(II) is octahedrally coordinated to six water molecules. This species is located in a cylindrical channel and rotates rapidly at room temperature. Evacuation at room temperature removes three of these water molecules, leaving the Cu (II) coordinated to three water molecules and anchored to oxygens in the channel wall. Dehydration at 45$0^{\circ}C$ produces one Cu (II) species located in the inner surface of a channel as evidenced by broadening of its ESR lines by oxygen. Adsorption of polar molecules such as water, methanol and ammonia on dehydrated CuNa-MCM-41 gallosilicate material causes changes in the ESR spectrum of Cu (II), indicating the complex formation with these adsorbates. Cu (II) forms a complex with six molecules of methanol as evidenced by an isotropic room temperature ESR signal and ESEM data like upon water adsorption. Cu(II) also forms a complex containing four molecules of ammonia based on resolved nitrogen superhyperfine interaction.

  • PDF

$CuF_{2}.2H_{2}O$의 펄스 핵자기공명 연구 (Pulsed NMR Study of $CuF_{2}.2H_{2}O$)

  • 이철의;윤은희;이창훈;김건;전승준
    • 한국자기학회지
    • /
    • 제3권1호
    • /
    • pp.13-17
    • /
    • 1993
  • 수소$(^{1}H)$와 불소$(^{19}F)$ 원자핵에 대한 펄스 핵자기공명 기법을 써서 $CuF_{2}.2H_{2}O$ 분말 시료를 연구하였다. 선모양과 스핀-격자 완화의 측정으로 공명 원자핵들은 격자내 상자성 이온들의 영향을 강하게 받음을 알 수 있었다. 또 이로부터 상자성 이온의 상관시간(correlation time)을 계산할 수 있었으며 관측된 공명선 폭과 스핀 메아리 붕괴상수로부터 스핀-스핀 상호작용의 크기와 공명원자핵들은 운동상태를 유추할 수 있었다.

  • PDF

자기공명영상을 이용한 금속전극의 정확한 위치 결정 (Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging)

  • 조은혜;김민호;하윤;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.11-21
    • /
    • 2011
  • 목적: 금속전극은 MRI 안에서 자기장의 왜곡을 일으켜 영상에 인공물이 나타난다. 본 논문에서는 전극이 B0와 수직으로 놓였을때 자기장 패턴의 특성을 이용하여 oblique-view angle imaging 방식을 통해 전극의 정확한 위치를 결정하는 방법을 제시하고자 한다. 대상 및 방법: 다양한 직경과 자화율을 가진 금속 전극모델의 시뮬레이션을 통하여 전극으로 인해 왜곡되는 field map의 양상을 파악하고 해상도에 따른 turbo spin-echo (TSE) 영상의 왜곡패턴을 분석하여 일반적인 영상기 법($90^{\circ}$ view)과 $45^{\circ}$ oblique-view에서의 위치 추정 기준을 마련하였으며 3.0T 임상용 장비에서 실제 전극의 TSE영상을 획득하여 시뮬레이션과 대조 검증하였다. 상대적으로 자기장의 왜곡에 민감한 gradient-refocused echo (GRE)시퀀스에서는 위상 영상을 이용해 위치를 추정하였다. 결과: 금속전극이 B0와 수직일 때 전극을 통과하는 $45^{\circ}$ 선상에서는 자기장 패턴의 변화가 매우 적었다. TSE 시퀀스의 경우 $45^{\circ}$ oblique-view 영상에서는 자화율의 크기에 관계없이 위치 추정기준이 잘 들어 맞았으며 자기장 왜곡에 의한 픽셀이 동양상이 양방향 대칭적으로 일어나므로 해상도가 낮은 경우에도 정확한 위치 추정이 가능하였다. 또한 GRE 시퀀스를 사용하였을때 $45^{\circ}$ oblique-view에서는 위상의 극성이 변화하는 선이 직교좌표계와 일치하기 때문에 일반적 방법보다 위치추정이 용이하였다. 결론: 시뮬레이션과 실제영상을 이용하여 일반적인 $90^{\circ}$ view에서보다 $45^{\circ}$ oblique-view에서 금속전극의 위치추정이 용이함을 확인하였다. 이는 전기 생리학적인 뇌연구 및 뇌수술 등을 MRI로 모니터링 하는데 적용 가능할 것으로 기대된다.

초고해상도 미세영상 기법을 이용한 Mouse 뇌의 자기공명영상 연구 (High-Resolution MRI Study on Mouse Brain Using Micro-Imaging)

  • 한덕영;윤문현;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.142-147
    • /
    • 2008
  • 목적 : 본 연구는 핵자기공명 분광기를 개조한 미세영상 기법을 이용하여, 동물실험에 주류를 이루는 mouse를 대상으로, 0.1 mm 이내의 초고해상도 자기공명영상을 5분 정도 시간 안에 획득할 수 있는 방법을 개발하고자 하였다. 대상 및 방법 : 사용된 mouse는 C57BL/6로서 무게 50 그램 이내의 mouse를 사용하였다. 본 연구에 활용된 초전도 자석은 구경 89 mm, 4.7 T의 자기장 세기를 가진 수직형 자석이며, 사용된 샘플 코일의 직경은 30 mm 이고, 사용된 펄스시퀀스는 fast spin echo (FSE) 및 gradient echo (GE) 기법들이다. 결과 : 최적의 자기공명영상 파라미터를 확보하면서 2차원 영상으로서 수소밀도 및 T2 강조 영상을 획득하였다. 영상으로부터 mouse 뇌의 미세부분까지 상세히 해부학적 구조를 확인할 수 있었고, 또한 입체적인 정보를 획득하기 위하여 3D 영상도 부가적으로 획득하였다. 조영제를 이용한 dynamic contrast 연구에 3D 영상이 매우 유용하였다. 결론 : 본 연구를 통하여 mouse 뇌에 대한 고해상도 자기공명영상 획득을 위한 최적의 파라미터를 확보할 수 있었고, 또한 성공적인 자기공명영상도 획득하였다. 즉, 사람이나 다른 소동물뇌의 경우와 같이 mouse 뇌 조직의 다양한 부위의 미세부분을 확인할 수 있는 충분한 고해상도의 영상을 획득하였다. 최근 국내에서 mouse를 이용한 자기공명영상 연구가 시작되었으나 아직 초기단계라고 평가할 수 있고, mouse는 다른 동물에 비하여 취급/관리하기 쉬우므로 향후 mouse를 이용한 뇌 연구가 활성화 될 것으로 사료된다.

  • PDF

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

Feasibility of Spin-Echo Echo-Planar Imaging MR Elastography in Livers of Children and Young Adults

  • Kim, Jin Kyem;Yoon, Haesung;Lee, Mi-Jung;Kim, Myung-Joon;Han, Kyunghwa;Koh, Hong;Kim, Seung;Han, Seok Joo;Shin, Hyun Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.251-258
    • /
    • 2019
  • Purpose: To assess the feasibility of the use of spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) in livers of children and young adults. Materials and Methods: Patients (${\leq}20$ years old) who underwent 3T SE-EPI MRE were included retrospectively. Subjects were divided into three groups according to the purpose of the liver MRI: suspicion of fatty liver or focal fat deposition in the liver (FAT group), liver fibrosis after receiving a Kasai operation from biliary atresia (BA group), and hepatic iron deposition after receiving chemotherapy or transfusions (IRON group). Technical failure of MRE was defined when a stiffness map showed no pixel value with a confidence index higher than 95%, and the patients were divided as success and failure groups accordingly. Clinical findings including age, gender, weight, height, and body mass index and magnetic resonance imaging results including proton density fat fraction (PDFF), $T2^*$, and MRE values were assessed. Factors affecting failure of MRE were evaluated and the image quality in wave propagation image and stiffness map was evaluated using the appropriate scores. Results: Among total 240 patients (median 15 years, 211 patients in the FAT, 21 patients in the BA, and 8 patients in the IRON groups), technical failure was noted in six patients in the IRON group (6/8 patients, 75%), while there were no failures noted in the FAT and BA groups. These six patients had $T2^*$ values ranging from 0.9 to 3.8 ms. The image quality scores were not significantly different between the FAT and BA groups (P > 0.999), while the scores were significantly lower in the IRON group (P < 0.001). Conclusion: The 3T SE-EPI MRE in children and young adults had a high technical success rate. The technical failure was occurred in children with decreased $T2^*$ value (${\leq}3.8ms$) from iron deposition.

Assessment of the Cerebrospinal Fluid Effect on the Chemical Exchange Saturation Transfer Map Obtained from the Full Z-Spectrum in the Elderly Human Brain

  • Park, Soonchan;Jang, Joon;Oh, Jang-Hoon;Ryu, Chang-Woo;Jahng, Geon-Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.139-149
    • /
    • 2019
  • Purpose: With neurodegeneration, the signal intensity of the cerebrospinal fluid (CSF) in the brain increases. The objective of this study was to evaluate chemical exchange saturation transfer (CEST) signals with and without the contribution of CSF signals in elderly human brains using two different 3T magnetic resonance imaging (MRI) sequences Methods: Full CEST signals were acquired in ten subjects (Group I) with a three-dimensional (3D)-segmented gradient-echo echo-planar imaging (EPI) sequence and in ten other subjects (Group II) with a 3D gradient and spin-echo (GRASE) sequence using two different 3T MRI systems. The segmented tissue compartments of gray and white matter were used to mask the CSF signals in the full CEST images. Two sets of magnetization transfer ratio asymmetry (MTRasym) maps were obtained for each offset frequency in each subject with and without masking the CSF signals (masked and unmasked conditions, respectively) and later compared using paired t-tests. Results: The region-of-interest (ROI)-based analyses showed that the MTRasym values for both the 3D-segmented gradient-echo EPI and 3D GRASE sequences were altered under the masked condition compared with the unmasked condition at several ROIs and offset frequencies. Conclusions: Depending on the imaging sequence, the MTRasym values can be overestimated for some areas of the elderly human brain when CSF signals are unmasked. Therefore, it is necessary to develop a method to minimize this overestimation in the case of elderly patients.

Assessment of the Location of the Peroneus Longus Tendon in the Cuboid Groove Using 3D Isotropic Fast Spin-Echo MRI

  • Lee, Ji Yoon;Choo, Hye Jung;Lee, Sun Joo;Jung, Joon-Yong;Kim, Dong Wook;Baek, Jin Wook;Heo, Young Jin;Gwak, Heui-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.21-29
    • /
    • 2020
  • Purpose: To investigate normal location of the peroneus longus tendon (PL) in the cuboid groove by evaluating it between ankles with no significant abnormality (asymptomatic group) and those with retromalleolar PL dislocation (dislocation group) using three-dimensional isotropic fast spin-echo (3D-FSE) magnetic resonance imaging (MRI) of the ankle. Materials and Methods: Thirty-six and 32 3D-FSE ankle MRI were assigned to the asymptomatic group and the dislocation group, respectively. Using multiplanar reformatted 3D-FSE, qualitative PL location (i.e., outside, overlying, and inside in relation to the cuboid groove), quantitative PL location (i.e., distance between the proximal margins of PL and cuboid groove), and cuboid groove size were measured in lateral, middle, and medial levels of the cuboid groove. Results: In the asymptomatic group, 64%, 42%, and 11%, respectively, had the outside or overlying-located PL in lateral, middle, and medial levels of the cuboid groove and the quantitative location gradually decreased from lateral to medial level. Qualitative and quantitative PL locations were not significantly different between the asymptomatic group and dislocation group. Cuboid groove size showed significant negative correlation with quantitative PL location in both groups. Conclusion: Outside- or overlying-located PL in lateral and middle levels of the cuboid groove would be a normal finding, regardless of PL status at the retromalleolar level.

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • 한국자기공명학회논문지
    • /
    • 제10권1호
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Location and Adsorbate Interactions of V(IV) Species in VH-SAPO-34 Studied by EPR and Electron Spin-Echo Modulation Spectroscopies

  • Gernho Back;Cho, Young-Soo;Lee, Yong-Ill;Kim, Yanghee;Larry Kevan
    • 한국자기공명학회논문지
    • /
    • 제5권2호
    • /
    • pp.73-90
    • /
    • 2001
  • Vanadium-doped H-SAPO-34 samples were prepared by a high-temperature solid-state reaction between SAPO-34 and the paramagnetic V(Ⅳ) species and characterized carefully by EPR and Electron Spin-Echo Modulation(ESEM) studies. The paramagnetic vanadium species generated in both V$_2$O$\_$5/ and VOSO$\_$4/ of SAPO-34 have the same narrow range of g value fur vanadium species assigned to VO$\^$2+/ inferred from the isotropic EPR spectrum at 293 K. The EPR and ESEM data indicate that the V(Ⅳ) species exist as a vanadyl ion either as [V(Ⅳ)]O$\^$2+/ or V$\^$4+/. The [V(Ⅳ)]O$\^$2+/ species seems to be more probable because SAPO-34 having a low negative framework charged and more positively charged species like V$\^$4+/can not be easily stabilized. Tetravalent vanadium ion in vadium-doped H- SAPO-34 can only be observed at the temperature lower than 77 K, while the vanadyl ion, VO$\^$2+/in the activated sample of VH-SAPO-34 can produce the ion even at room temperature. After the adsorption of methanol, ethanol, propanol or ethene to the VH-SAPO-34, only one molecule coordinate to [V(Ⅳ)]O$\^$2+/ was observed in EPR and ESEM spectra.

  • PDF