• 제목/요약/키워드: specification deviation

검색결과 46건 처리시간 0.022초

엔진 고공 시험에서 공기 유량 측정용 벤투리 파이프의 제작 및 측정 불확도 분석 (Manufacture and Measurement Uncertainty Analysis of a Venturi Pipe for Airflow Measurement in Altitude Engine Test)

  • 양인영;오중환
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.36-41
    • /
    • 2010
  • Design, manufacture and calibration procedures of a venturi pipe flowmeter for airflow measurement in altitude engine test were discussed. Altitude engine test using venturi pipe was given as an example. The venturi was designed per the ISO standard of ISO5167, and was intented to include the entire airflow range in the test envelope of the gas turbine engine. Measurement uncertainty analysis was performed in the design procedure to investigate the effect of venturi geometry and sensor specification upon the measurement uncertainty. Manufacturing process was designed to minimize the deviation from the geometry of design. Calibration was performed to get the relationship between the discharge coefficient and the pipe Reynolds number. Then the uncertainty was assessed again using real data acquired during engine test. Through these procedures, it was possible to maintain the uncertainty of airflow measurement under 1 % for most of the operating envelope of the gas turbine engine. The discharge coefficient of the venturi pipe showed agreement with the value suggested in the ISO standard ISO5167-4 within 0.6 %.

Acoustic Measurement of English read speech by native and nonnative speakers

  • Choi, Han-Sook
    • 말소리와 음성과학
    • /
    • 제3권3호
    • /
    • pp.77-88
    • /
    • 2011
  • Foreign accent in second language production depends heavily on the transfer of features from the first language. This study examines acoustic variations in segments and suprasegments by native and nonnative speakers of English, searching for patterns of the transfer and plausible indexes of foreign accent in English. The acoustic variations are analyzed with recorded read speech by 20 native English speakers and 50 Korean learners of English, in terms of vowel formants, vowel duration, and syllabic variation induced by stress. The results show that the acoustic measurements of vowel formants and vowel and syllable durations display difference between native speakers and nonnative speakers. The difference is robust in the production of lax vowels, diphthongs, and stressed syllables, namely the English-specific features. L1 transfer on L2 specification is found both at the segmental levels and at the suprasegmental levels. The transfer levels measured as groups and individuals further show a continuum of divergence from the native-like target. Overall, the eldest group, students who are in the graduate schools, shows more native-like patterns, suggesting weaker foreign accent in English, whereas the high school students tend to involve larger deviation from the native speakers' patterns. Individual results show interdependence between segmental transfer and prosodic transfer, and correlation with self-reported proficiency levels. Additionally, experience factors in English such as length of English study and length of residence in English speaking countries are further discussed as factors to explain the acoustic variation.

  • PDF

Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

  • Baek, Kwang Ki;Park, Chung Seo;Kim, Ki Hong;Chung, Mong Kyu;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.27-32
    • /
    • 2006
  • One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities.

멀티레벨 변조방식에서 LDPC 복호 알고리즘 (LDPC Decoding Algorithm for Multi-level Modulation Scheme)

  • 이인기;정지원;최덕군;최은아;장대익;오덕길
    • 한국통신학회논문지
    • /
    • 제30권6C호
    • /
    • pp.434-441
    • /
    • 2005
  • 8PSK 이상의 멀티 레벨 변조 방식에서는 LDPC 복호를 위해서는 수신 심볼의 Inphase와 Quadrature 성분을 이용하여 각각의 비트로 분리하여야 하며, 성능은 각각의 비트의 거리와 관계가 있기 때문에 분리 하는 방식이 성능에 영향을 미치게 된다. 따라서 본 논문에서는 기존의 유클리디언 거리를 이용하여 분리하는 방식을 분석하고 이는 하드웨어 구현 관점에서 많은 계산량을 필요로 하기 때문에 약간의 성능 감소를 가지더라도 섹터를 이용하는 방식을 제안한다. 또한 DVB-S2에서는 BC(Backward Compactible) 모드를 제공한다. BC 모드에서는 변조방식이 계층적 변조 방식인데 즉 변조시 심볼의 위상이 non-uniform 하게 분포되는데 본 연구에서는 non-uniform한 위상 분포에서 각각 인접한 심볼의 위상의 각도에 따른 LDPC 성능을 분석하였다.

웨이블렛 변환을 이용한 태양광 발전시스템의 고장진단에 관한 연구 (A Study on the Fault Detection Technique of the Grid-Connected Photovoltaic System using Wavelet Transformation)

  • 이정은;김일송
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.79-87
    • /
    • 2011
  • 본 논문에서는 웨이블렛(Wavelet) 변환을 이용한 태양광 발전시스템의 고장진단에 관한 연구를 수행하였다. 기존에는 추가적인 하드웨어와 센서를 사용하여 인버터의 고장을 진단하는 방법으로, 단가가 상승하고 사양이 바뀔 경우 재설계를 해야 하는 문제점이 있었다. 제안된 방식은 인버터 전류나 전압과 같은 상태변수들을 다단계 변환을 통해 얻어낸 웨이블렛 계수들의 변화를 감지하여 고장의 종류와 부위를 인식하는 방법이다. 정규화 표준 편차를 이용하여 웨이블렛 계수의 변화로부터 정확하고 신속한 고장 진단이 가능하다. 이 방법은 간단한 계산과 고장 유형을 정확하게 예측할 수 있는 장점이 있다. 컴퓨터 시뮬레이션과 제어기 제작을 통한 실험 결과로서 연구의 타당성을 입증하였다.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • 이수원;정태곤;양재웅;정재영;박광민;정용훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

상용급 재가열로에서 소재 온도 예측을 위한 해석과 실험 결과의 비교 분석 (The Comparative Analysis of Numerical and Experimental Results for Prediction of Workpiece Temperature in the Commercial Reheating Furnace)

  • 이춘식;이재용;유보현;임동렬
    • 한국가스학회지
    • /
    • 제23권4호
    • /
    • pp.74-79
    • /
    • 2019
  • 상용급 재가열로 내부 소재 온도 측정을 위하여 특수 제작된 시험용 시편을 사용하고, 실시간 온도 예측을 위하여 선형화 된 열모델이 적용되었다. 적용된 로는 Walking Beam Type이고 소재의 형상은 폭 160mm, 높이 160mm, 길이 8100mm의 STS302 재질이며 온도 측정을 위해 폭, 높이와 길이 방향으로 총 6개의 열전대를 설치하였다. 로내의 분위기 온도는 섭씨 1265도까지 상승시켰으며 소재의 장입부터 토출까지 약 2.5시간이 소요되었다. 시험결과, 토출 시 소재의 온도는 섭씨 1256~1259도 범위에서 평균적으로 1257도 였으며, 열모델을 통한 예측된 평균 온도는 1251도로 나타났다. 따라서 해석과 시험결과의 편차는 6도 정도로서, 이는 산업계에서 요구되는 10도 이내의 범위에 있다.

LC-MS/MS를 이용한 종자류 생약의 곰팡이독소 동시분석 및 위해도 평가 (Simultaneous Analysis of Mycotoxins and Risk Assessment in Seeds using LC-MS/MS)

  • 최은정;박영애;최수정;정삼주;박윤선;황인숙;유인실;신기영
    • 생약학회지
    • /
    • 제51권4호
    • /
    • pp.270-277
    • /
    • 2020
  • This study analyzed mycotoxins, aflatoxin B1, B2, G1, G2, fumonisin B1, B2, ochratoxin A and zearalenone, using LC-MS/MS and conducted risk assessment on 54 samples of seeds distributed in SeoulYangnyeongsi and the management status of extramural herbal dispensary facility. The matched calibration showed a good linearity as observed in 6 concentration levels(r2>0.999) as a result of method validation applied with Arecae semen. Limits of detection(LOD) and quantification(LOQ) were in the range of 0.02-0.11 ㎍/kg and 0.08-0.34 ㎍/kg, respectively. Recoveries also estimated, ranging from 65.1-99.7% with relative standard deviation(RSD) 0.5-6.3%. As a result of the method on 54 samples, mycotoxins were detected in 16 samples. Among them, two Thujae semen showed a degree of concentration that exceeded the aflatoxin specification. In the risk assessment, the human exposure safety standard values were calculated as ADI(Acceptable Daily Intake) for aflatoxin B1, fumonisin and zearalenone. Ochratoxin A was calculated as PTWI(Provisional Tolerable Weekly Intake). The MOE(Margine of Exposure) of aflatoxin B1 was in the range of 40.36-3536.88. And no items exceeded 100% in %TDI(Tolerable Daily Intake) and %TWI(Tolerable Weekly Intake) of fumonisin, zearalenone and ochratoxin A.

레지스터 전달 수준 설계단계에서 사전 클럭트리합성 가능여부 판단을 위한 경량화된 클럭트리 재구성 방법 (Lightweighted CTS Preconstruction Techniques for Checking Clock Tree Synthesizable Paths in RTL Design Time)

  • 권나영;박대진
    • 한국정보통신학회논문지
    • /
    • 제26권10호
    • /
    • pp.1537-1544
    • /
    • 2022
  • application specific integrated circuit (ASIC) 및 system on chip (SoC) 설계 시 디지털 회로는 클럭에 동기화되어 작동한다. 칩 설계 시, place & route (P&R)에서 설계 조건과 타이밍 조건, 클럭의 동기화 여부 등을 고려한다. P&R에서 클럭 경로에 대한 delay를 줄이기 위해, clock tree synthesis (CTS) 기법을 이용한다. 본 논문에서는 사전 클럭트리 합성 가능 여부 판단을 위한 shallow-CTS 알고리즘을 소개한다. 오픈 소스 Parser-Verilog를 사용하여 register transfer level (RTL) 합성가능한 Verilog를 파싱하여, Pre-CTS와 Post-CTS 단계를 진행하고, 가장 긴 clock path와 버퍼 삽입 전후의 표준편차를 비교하여 CTS의 정확도에 대해 분석한다. 본 논문에서 시간 투입이 많이 되는 licensed EDA tool을 사용하여 CTS 결과를 확인하지 않고, RTL 수준에서 사전 클럭 트리 합성 검증 방법을 제공하여 비용 및 시간문제를 감소할 수 있을 것으로 기대된다.

공정 안정성 평가를 위한 새로운 척도 지수 계발 (Development of a New Index to Assess the Process Stability)

  • 김정배;윤원영;서순근
    • 품질경영학회지
    • /
    • 제50권3호
    • /
    • pp.473-490
    • /
    • 2022
  • Purpose: The purpose of this study is to propose a new useful suggestion to monitor the stability of process by developing a stability ratio or index related to investigating how well the process is controlled or operated to the specified target. Methods: The proposed method to monitor the stability of process is building up a new measure index which is making up for the weakness of the existing index in terms of short or long term period of production. This new index is a combined one considering both stability and capability of process to the specification limits. We suppose that both process mean and process variation(or deviation) are changing on time period. Results: The results of this study are as follows: regarding the stability of process as well as capability of process, it was shown that two indices, called SI(stability index) and PI(performance index), can be expressed in two-dimensional X-Y graph simultaneously. This graph is categorized as 4 separated partitions, which are characterized by its numerical value intervals of SI and PI which are evaluated by test statistics. Conclusion: The new revised index is more robust than the existing one in investigating the stability of process in terms of short and long period of production, even in case both process mean and variation are changing.