• Title/Summary/Keyword: spatial qualify

Search Result 32, Processing Time 0.016 seconds

The Effect of Freshwater Inflow on the Spatio-temporal Variation of water Qualify of Yeongil Bay (영일만 수질의 시ㆍ공간 변동에 미치는 담수유입의 효과)

  • 김영숙;김영섭
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • In order to determine the effect of fresh water inflow from the Heongsan river on the changes of water quality in the Yeongil Bay (Korea), the seasonal changes of water temperature, salinity, chemical oxygen demand (COD), dissolved inorganic nitrogen(DIN) and phosphate phosphorus ($PO_4$-P) concentrations were examined using the data set obtained five fixed points of Yeongil Bay from 1998 to 2000. The distributions and changes of COD and concentrations of total inorganic phosphorous (TIP) and nitrogen (TIN) at three points Heongsan river, were also compared with those of Yeongil Bay. Based on the correlations of DIN and $PO_4$-P, it was found that the inflow of freshwater affected on the water quality of Yeongil Bay. Such a complicacy was confirmed by the prominent differences in n few water quality measures between Site 1(the innermost area) and Site 5 (the mouth of the bay). The negative correlations in $\Delta N/\Delta P $ at sites 1, 2 and 3 of the inner-part of the bay also indicated a large effect of freshwater inflow on the water quality of the bay. The extremely low atomic ratio of an average of 6.4 in $\Delta N/\Delta P $ compared to the Redfild ratio suggested that the DIN was depleted in the overall bay system. In contrast, it was inferred that the excessive PO$_4$-P concentration was due to the inflow of freshwater from the Heongsan river.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF