• Title/Summary/Keyword: span number

Search Result 550, Processing Time 0.031 seconds

Effect of flap angle on transom stern flow of a High speed displacement Surface combatant

  • Hemanth Kumar, Y.;Vijayakumar, R.
    • Ocean Systems Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2020
  • Hydrodynamic Drag of Surface combatants pose significant challenges with regard to fuel efficiency and exhaust emissions. Stern flaps have been used widely as an energy saving device, particularly by the US Navy (Hemanth et al. 2018a, Hemanth Kumar and Vijayakumar 2018b). In the present investigation the effect of flap turning angle on drag reduction is numerically and experimentally studied for a high-speed displacement surface combatant fitted with a stern flap in the Froude number range of 0.17-0.48. Parametric investigations are undertaken for constant chord length & span and varying turning angles of 5° 10° & 15°. Experimental resistance values in towing tank tests were validated with CFD. Investigations revealed that pressure increased as the flow velocity decreased with an increase in flap turning angle which was due to the centrifugal action of the flow caused by the induced concave curvature under the flap. There was no significant change in stern wave height but there was a gradual increase in the stern wave steepness with flap angle. Effective length of the vessel increased by lengthening of transom hollow. In low Froude number regime, flow was not influenced by flap curvature effects and pressure recovery was marginal. In the intermediate and high Froude number regimes pressure recovery increased with the flap turning angle and flow velocity.

Damage identification of substructure for local health monitoring

  • Huang, Hongwei;Yang, Jann N.
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.795-807
    • /
    • 2008
  • A challenging problem in structural damage detection based on vibration data is the requirement of a large number of sensors and the numerical difficulty in obtaining reasonably accurate results when the system is large. To address this issue, the substructure identification approach may be used. Due to practical limitations, the response data are not available at all degrees of freedom of the structure and the external excitations may not be measured (or available). In this paper, an adaptive damage tracking technique, referred to as the sequential nonlinear least-square estimation with unknown inputs and unknown outputs (SNLSE-UI-UO) and the sub-structure approach are used to identify damages at critical locations (hot spots) of the complex structure. In our approach, only a limited number of response data are needed and the external excitations may not be measured, thus significantly reducing the number of sensors required and the corresponding computational efforts. The accuracy of the proposed approach is illustrated using a long-span truss with finite-element formulation and an 8-story nonlinear base-isolated building. Simulation results demonstrate that the proposed approach is capable of tracking the local structural damages without the global information of the entire structure, and it is suitable for local structural health monitoring.

Flexural and compression behavior for steel structures strengthened with Carbon Fiber Reinforced Polymers (CFRPs) sheet

  • Park, Jai-woo;Yoo, Jung-han
    • Steel and Composite Structures
    • /
    • v.19 no.2
    • /
    • pp.441-465
    • /
    • 2015
  • This paper presents the experimental results of flexural and compression steel members strengthened with carbon fiber reinforced polymers (CFRP) sheets. In the flexural test, the five specimens were fabricated and the test parameters were the number of CFRP ply and the ratio of partial-length bonded CFRP sheets of specimen. The CFRP sheet strengthened steel beam had failure mode: CFRP sheet rupture at the mid span of steel beams. A maximum increase of 11.3% was achieved depending on the number of CFRP sheet ply and the length of CFRP sheet. In the compression test, the nine specimens were fabricated and the main parameters were: width-thickness ratio (b/t), the number of CFRP ply, and the length of the specimen. From the tests, for short columns it was observed that two sides would typically buckle outward and the other two sides would buckle inward. Also, for long columns, overall buckling was observed. A maximum increase of 57% was achieved in axial-load capacity when 3 layers of CFRP were used to wrap HSS columns of b/t = 60 transversely.

Response modification factor and seismic fragility assessment of skewed multi-span continuous concrete girder bridges

  • Khorraminejad, Amir;Sedaghati, Parshan;Foliente, Greg
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.389-403
    • /
    • 2021
  • Skewed bridges, being irregular structures with complicated dynamic behavior, are more susceptible to earthquake damage. Reliable seismic-resistant design of skewed bridges can be achieved by accurate determination of nonlinear seismic demands. However, the effect of geometric characteristics on the response modification factor (R-factor) is not accounted for in bridge design practices. This study attempts to investigate the effects of changes in the number of spans, skew angle and bearing stiffness on R-factor values and to assess the seismic fragility of skewed bridges. Results indicated that changes in the skew angle had no significant effect on R-factor values which were in consonance with code-prescribed R values. Also, unlike the increase in the number of spans that resulted in a decrease in the R-factor, the increase in bearing stiffness led to higher R-factor values. Findings of the fragility analysis implied that although the increase in the number of spans, as well as the increase in the skew angle, led to a higher failure probability, greater values of bearing stiffness reduced the collapse probability. For practicing design engineers, it is recommended that maximum demands on substructure elements to be calculated when the excitation angle is applied along the principal axes of skewed bridges.

Influence of geometric configuration on aerodynamics of streamlined bridge deck by unsteady RANS

  • Haque, Md. N.;Katsuchi, Hiroshi;Yamada, Hitoshi;Kim, Haeyoung
    • Wind and Structures
    • /
    • v.28 no.5
    • /
    • pp.331-345
    • /
    • 2019
  • Long-span bridge decks are often shaped as streamlined to improve the aerodynamic performance of the deck. There are a number of important shaping parameters for a streamlined bridge deck. Their effects on aerodynamics should be well understood for shaping the bridge deck efficiently and for facilitating the bridge deck design procedure. This study examined the effect of various shaping parameters such as the bottom plate slope, width ratio and side ratio on aerodynamic responses of single box streamlined bridge decks by employing unsteady RANS simulation. Steady state responses and flow field were analyzed in detail for wide range of bottom plate slopes, width and side ratios. Then for a particular deck shape Reynolds number effect was investigated by varying its value from $1.65{\times}10^4$ to $25{\times}10^4$. The aerodynamic response showed very high sensitivity to the considered shaping parameters and exhibited high aerodynamic performance for a particular combination of shaping parameters.

Evaluation of lateral stiffness of steel structures having different types of lateral load-resisting systems

  • Kabir Sadeghi;Krekar Kadir Nabi;Fatemeh Nouban
    • Advances in Computational Design
    • /
    • v.9 no.3
    • /
    • pp.151-165
    • /
    • 2024
  • In this paper, the evaluation of the elastic lateral stiffness factor (ELSF) of steel frames for different lateral load-resisting systems (LLRSs) is presented. First, 720 steel structural frame models have been analyzed and designed using the equivalent lateral force method. Then by using pushover analysis method, all models have been analyzed, compared and evaluated. Finally, the effects of a number of influenced parameters such as different types of LLRSs, span length, number of stories, number of spans as well as story height of the buildings on the lateral stiffness are assessed and by applying regression analysis some useful equations were submitted. Based on the results obtained for steel frames having different LLRSs, compared to ordinary moment-resisting frames (OMRFs) as a base (having ELSF of 1), the normalized average ELSFs of K-eccentrically braced-frames (K-EBFs), V-, Z-, inverted V-, X-braced-frames, shear walls with thickness of 25 cm (SW25) and shear walls with thickness of 30 cm (SW30) are about 2.2, 6, 7, 9, 11, 95, 155, respectively. Among the braced-frames, X-braced-frames have the maximum ELSF, about 10 times more than OMRF, while OMRFs provide the minimum ELSFs among all LLRSs, and the frames supported by shear walls have ELSFs about 100 to 150 times more than OMRFs.

Numerical study on Reynolds number effects on the aerodynamic characteristics of a twin-box girder

  • Laima, Shujin;Wu, Buchen;Jiang, Chao;Chen, Wenli;Li, Hui
    • Wind and Structures
    • /
    • v.28 no.5
    • /
    • pp.285-298
    • /
    • 2019
  • For super long-span bridges, the aerodynamic forces induced by the flow passing the box girder should be considered carefully. And the Reynolds number sensitively of aerodynamic characteristics is one of considerable issue. In the study, a numerical study on the Reynolds number sensitivity of aerodynamic characteristic (flow pattern, pressure distribution and aerodynamic forces) of a twin-box girder were carried out using large eddy simulation (LES) with the dynamic Smagorinsky-Lilly subgrid model. The results show that the aerodynamic characteristics have strong correlation with the Reynolds number. At the leading edge, the flow experiences attachment, departure, and reattachment stages accompanying by the laminar transition into turbulence, causing pressure plateaus to form on the surface, and the pressure plateaus gradually shrinks. Around the gap, attributing that the flow experiences stages of laminar cavity flow, the wake with alternate shedding vortices, and turbulent cavity flow in sequence with an increase in the Reynolds number, the pressures around the gap vary greatly with the Reynold number. At the trailing edge, the pressure gradually recovers as the flow transits to turbulence (the flow undergoes wake instability, shear layer transition-reattachment station), In addition, at relative high Reynolds numbers, the drag force almost does not change, however, the lift force coefficient gradually decreases with an increase in Reynolds number.

AN EXPERIMENTAL STUDY ON TUMOR INHIBITORY EFFECT OF RED GINSENG IN MICE AND RATS EXPOSED TO VARIOUS CHEMICAL CARCINOGENS

  • Yun Taik Koo;Yun Yeon Sook;Han In Won
    • Proceedings of the Ginseng society Conference
    • /
    • 1980.09a
    • /
    • pp.87-113
    • /
    • 1980
  • This experiment was carried out to evaluate the effects of Korean ginseng extract on carcinogenesis induced by various chemical carcinogens. Red ginseng extract was used for this study and was administered orally to the experimental animals. Carcinogens that were injected in subscapsular region of ICR newborn mice within 24 hours after birth were 9,10-dimethyl-1,2-benzan-thracene (DMBA), urethane, N-2-fluorenylacetamide(AAF), aflatoxin $B_1$ and tobacco smoke condensate. N -methyl-N -nitroso-N'-nitroguani-dine(MNNG) was injected subcutaneously at the back of wistar rats. Experimental animals were autopsied in immediately after being sacrificed. All major organs were examined grossly and weighted. After fixation histopathological preparations were made for microscopical study. Following results were obtained. In DMBA group sacrificed at the 26th week after the treatment with DMBA, the incidence of lung adenoma was $77\%$ and the average number of the tumor was 17. However, in DMBA combined with red ginseng group, the incidence was $78\%$ and the average number of lung adenoma was 14.1. This indicates that ginseng extract had no effect on the incidence of lung adenoma but decreased the average number of lung adenoma by $17\%.$ In DMBA group sacrificed at the 48th week after the injection of DMBA, the lung adenoma incidence was $88\%.$ The average diameter of the largest lung adenoma was 3.5 cm, the incidence of diffuse pulmonary infiltration was $18\%$ and the average lung weight of male experimental mice was $528.2{\pm}469.1\;gm.$ On the other hand, in DMBA combined with red ginseng group sacrificed at the 48th week, the incidence of lung adenoma was $96\%.$ The average diameter of the largest adenoma was 2.7 cm, the incidence of diffuse pulmonary infiltration was $7\%$ and the average lung weight of male mice was $418.0{\pm}520\;gm.$ These observations show that ginseng extract did not have any inhibitory effect on the incidence of lung adenoma but decreased the average diameter of the largest lung adenoma by $23\%,$ the incidence of duffuse pulmonary infiltration by $63\%$ and the average lung weight of male experimental mice by $21\%.$ From these results we have found that the prolonged administration with ginseng extract showed no inhibitory effect on the incidence of adenoma but it had the inhibitory effect on the proliferation of lung adenomas induced by DMBA. In urethane group sacrificed at the 28th week after the injection of urethane, the incidence of lung adenoma was $94\%$ and the average number of lung adenoma was 8.6. In urethane combined with red ginseng group, the. incidence of lung adenoma was $73\%$ and the average number of adenoma was 6.0. These results indicate that there were $22\%$ decrease of the lung adenoma incidence and $31\%$ decrease of the average number of adenoma in urethane combined with red ginseng group. And in urethane group sacrificed at the 50th week, the incidence of lung adenoma was $98\%$ and the incidence of diffuse pulmonary infiltration was $14\%$. In urethane combined with ginseng group the incidence of lung adenoma was $85\%$ and the incidence of diffuse pulmonary infiltration was $12\%$. Therefore the ginseng administration resulted in $15\%$ decrease of the lung adenoma incidence and $14\%$ decrease of the diffuse pulmonary infiltration incidence. From these results we knew that the prolonged administration with ginseng extract inhibited the incidence and also the proliferation of the lung adenoma induced by urethane. Lung adenoma and hepatoma were induced in the experimental mice sacrificed at the 68th week but not in the experimental mice sacrificed at the 28th week after the injection of AAF. In AAF group sacrificed at the 68th week after the injection of AAF the incidence of lung adenoma was $18\%$ and the incidence of hepatoma was $27\%$. And in AAF combined with ginseng group the lung adenoma incidence was $12\%$ and the hepatoma incidence was $37\%$. So the ginseng seemed to decrease the lung adenoma incidence by AAF, but we were unable to conclude the significant inhibitory effect of the ginseng extract on the incidence of lung adenoma by AAF because the above incidence of lung adenoma were similar to that of control group which was $11\%$. And these experimental data revealed that ginseng extract didn't have any inhibitory effect on the incidence of hepatoma induced by AAF. In aflatoxin $B_1$ group sacrificed at the 56th week, the incidence of lung adenoma was $24\%$ and hepatoma was $11\%$. However in aflatoxin $B_1$ combined with ginseng group the incidence of lung adenoma was $17\%$ and hepatoma was $3\%$ These results indicate that there were $29\%$ decrease of the lung adenoma incidence and $75\%$ decrease of the hepatoma incidence in aflatoxin $B_1$ combined with ginseng group. In tobacco smoke condensate experimental group sacrificed at 67th week, no tumors were induced except just a few lung adenoma. The lung adenoma incidence both in tobacco smoke condensate group and in tobacco smoke condensate combined with ginseng group was $8\%$. And this incidence rate was similar to that of control group. These results indicate that the injection of 320 ug tobacco smoke condensate per ICR newborn mouse was unable to induce lung adenoma in our experiments. In MNNG group sacrificed at the 27th week the tumor incidence was $38.5\%$ and in MNNG combined with ginseng extract group was $37\%$. In MNNG group for investigation of the life span of tumor bearing rats the tumor incidence was $93\%$ and the average life span of tumor bearing rats was 318 days. And in MNNG combined with ginseng extract group the tumor incidence was $96\%$ and the average life span was 337 days. Tumor induced by MNNG was almost sarcoma. This indicates that there was no inhibitory effect of ginseng extract on the tumor incidence, but the extract prolonged the average life span of tumor bearing rats by approximately 19 days.

  • PDF

The effect of anti-cancer and Immune response improvement of ELP(Eclipta prostrata) Herbal-Acupuncture into Chok-samni(St36) (족삼리(足三里)에 시술(施術)한 한연초(旱蓮草) 약침(藥鍼)의 면역증진(免疫增進)과 항암작용(抗癌作用)에 관한 연구(硏究))

  • Jung, Young-don;Lee, Hyun;Lee, Byung-ryul;Yim, Yun-kyoung
    • Journal of Acupuncture Research
    • /
    • v.20 no.3
    • /
    • pp.141-153
    • /
    • 2003
  • To study the effects of anti-cancer, anti-metastasis and immune response improvement of herbal-acupuncture with Eclipta prostrata diffuse herba infusion solution(ELP-HAS), we injected ELP-HAS into Chok-samni(St36) of C57BL/6 mice implanted intravenously with B16-F10 melanoma. We have reached the following conclusion through the effect on the number of $CD25^+/CD4^+$, $CD8^+/CD3e^+$, $CD69^+/B220^+$, $NK1.1+/CD3e^+$ cells in mouse PBMCs, the effect on the pulmonary colony number, and the effect on MST(Median Survival Time) and ILS(Increase of Life Span) of C57BL/6 mice implanted intravenously with B16-F10 melanoma The results were obtained as follows: 1. In the experiment groups treated with ELP(Eclipta prostrata) Herbal-Acupuncture, the spleen cell proliferation in Balb/c mouse was significantly increased compared with control group. 2. In the experiment groups treated with ELP(Eclipta prostrata) Herbal-Acupuncture, the percentage of $CD25^+/CD4^+$, $CD8^+/CD3e^+$, $CD69^+/B220^+$, $NK1.1^+/CD3e^+$ cells in C57Bl/6 mouse PBMCs was increased compared with control group. 3. In the experiment groups treated with ELP(Eclipta prostrata) Herbal-Acupuncture, the pulmonary colony number of C57BL/6 mice implanted intravenously with B16-F10 melanoma was decreased significantly compared with control group. 4. In the experiment groups treated with ELP(Eclipta prostrata)Herbal-Acupuncture, MST(Median Survival Time) and ILS(Increase of Life Span) of C57BL/6 mice implanted intravenously with B16-F10 melanoma were increased significantly compared with control group.

  • PDF

A Comparative Analysis of the Kinetic Structure in Lectures on a High School Science (고등학교 공통 과학 강의에서 교사에 따른 역동적 구조의 정량적 비교 분석)

  • Yu, Seung-Geun;Lee, Joon-Sang
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.4
    • /
    • pp.505-509
    • /
    • 2000
  • The kinetic structure of the content of instructions at the unit of 'heart and circulation' in "the common science", which was respectively given by two teachers majored in biology and two teachers majored in earth science was investigated. Concerning of the mean of the fundamental coefficient (B1), the mean of weighted coefficients (B2) and the progression of instruction (P), T4 (B1, 0.14; B2, 0.82; P; 0.86) teacher showed relatively lower kinetic structure and faster progression than those of the others. The other teachers showed a different level of the kinetic structure and progression: T1(B1, 0.21; B2, 0.86; P; 0.79), T2 (B1, 0.02; B2, 0.85; P; 0.80), and T3 (B1, 0.22; B2, 0.83; P; 0.78). T1 teacher who showed the largest total frequency of verbal elements, the great number of sorts of verbal elements and secondary span, had a higher level of the kinetic structure, but T4 teacher showed the lowest level of total frequency of verbal elements, the great number of sorts of verbal elements and secondary span. The main reason why T4 teacher's instruction achieved a lower level of kinetic structure was estimated that he neglected to reorganize teaching materials and he showed a small number of discourse units. In addition, the unit of 'heart and circulation' was less related to T4 teacher's major and T4 teacher had a shorter teaching experience than those of the others. T4 teacher also took charge of only one class, and this did not allow to instruct repeatedly.

  • PDF