• Title/Summary/Keyword: space grid structure

Search Result 115, Processing Time 0.024 seconds

Hilbert Cube for Spatio-Temporal Data Warehouses (시공간 데이타웨어하우스를 위한 힐버트큐브)

  • 최원익;이석호
    • Journal of KIISE:Databases
    • /
    • v.30 no.5
    • /
    • pp.451-463
    • /
    • 2003
  • Recently, there have been various research efforts to develop strategies for accelerating OLAP operations on huge amounts of spatio-temporal data. Most of the work is based on multi-tree structures which consist of a single R-tree variant for spatial dimension and numerous B-trees for temporal dimension. The multi~tree based frameworks, however, are hardly applicable to spatio-temporal OLAP in practice, due mainly to high management cost and low query efficiency. To overcome the limitations of such multi-tree based frameworks, we propose a new approach called Hilbert Cube(H-Cube), which employs fractals in order to impose a total-order on cells. In addition, the H-Cube takes advantage of the traditional Prefix-sum approach to improve Query efficiency significantly. The H-Cube partitions an embedding space into a set of cells which are clustered on disk by Hilbert ordering, and then composes a cube by arranging the grid cells in a chronological order. The H-Cube refines cells adaptively to handle regional data skew, which may change its locations over time. The H-Cube is an adaptive, total-ordered and prefix-summed cube for spatio-temporal data warehouses. Our approach focuses on indexing dynamic point objects in static spatial dimensions. Through the extensive performance studies, we observed that The H-Cube consumed at most 20% of the space required by multi-tree based frameworks, and achieved higher query performance compared with multi-tree structures.

Investigation of Turbulent Analysis Methods for CFD of Gas Dispersion Around a Building (건물주위의 가스 확산사고에 대한 CFD 난류 해석기법 검토)

  • Ko, Min Wook;Oh, Chang Bo;Han, Youn Shik;Do, Kyu Hyung
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.42-50
    • /
    • 2015
  • Three simulation approaches for turbulence were applied for the computation of propane dispersion in a simplified real-scale urban area with one building:, Large Eddy Simulation (LES), Detached Eddy Simulation (DES), and Unsteady Reynolds Averaged Navier-Stokes (RANS). The computations were performed using FLUENT 14, and the grid system was made with ICEM-CFD. The propane distribution depended on the prediction performance of the three simulation approaches for the eddy structure around the building. LES and DES showed relatively similar results for the eddy structure and propane distribution, while the RANS prediction of the propane distribution was unrealistic. RANS was found to be inappropriate for computation of the gas dispersion process due to poor prediction performance for the unsteady turbulence. Considering the computational results and cost, DES is believed to be the optimal choice for computation of the gas dispersion in a real-scale space.

Restoration planning of the Seoul Metropolitan area, Korea toward eco-city

  • Lee, Chang Seok
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2003.06a
    • /
    • pp.1-5
    • /
    • 2003
  • In order to prepare a basis for ecological restoration of the Seoul Metropolitan area, ecological diagnoses on soil physico-chemical properties and vegetation structure were carried out. Land use patterns, actual vegetation, and biotope patterns were also investigated based on aerial photograph interpretation and field checks. I formulated landscape elements overlaying those data and evaluated the ecological value of each element. Soil pollution was evaluated by analyzing soil samples collected in each grid on the mesh map, divided by 2km $\times$ 2km intervals. Soil samples were collected in forests or grasslands escaped from direct human interference. Soil pollution evaluated from pH, and SO$_4$, Ca, Mg, and Al contents of soil was more severe in the urban outskirts than in the urban center. Those soil environmental factors showed significant correlation with each other. Vegetation in the urban area was different in species composition from that in suburban areas and showed lower diversity compared with that in the suburban areas. Successional process investigated by population structure of major species also showed a difference. That is, successional trend was normal in suburban areas, but that in urban areas showed a retrogressive pattern. The landscape ecological map of Seoul indicates that the urban center lacks vegetation and greenery space is restricted in urban outskirts. Such an uneven distribution of vegetation has caused a specific urban climate and thereby contributed to aggravation of air and soil pollution, furthermore causing vegetation decline. From this result, it was estimated that such uneven distribution of vegetation functioned as a trigger factor to deteriorate the urban environment. I suggested, therefore, a restoration plan based on landscape ecological principles, which emphasizes connectivity and even distribution of green areas throughout the whole area of the Seoul to solve this complex environmental problem. In this restoration plan, first of all, I decided the priority order for connection of the fragmented greenery spaces based on the distances from the core reserves comprised of green belt and rivers, which play roles as habitats of wildlife as well as for improvement of urban environment. Next, I prepared methods to restore each landscape element included in the paths of green network to be constructed in the future on the bases of such preferential order. Rivers and roads, which hold good connectivity, were chosen as elements to play important roles in constructing green network by linking the fragmented greenery spaces.

  • PDF

Evaluation on the Behavioral Characteristics of Plastic Greenhouse by Full-scale Testing and Finite Element Analysis (재하시험과 유한요소해석에 의한 플라스틱 필름 온실의 거동특성 분석)

  • Ryu, Hee Ryong;Lee, Eung Ho;Cho, Myeong Whan;Yu, In Ho;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.459-465
    • /
    • 2012
  • This study analyzed the effect of semi-rigid rafter-purlin cross-linking connection and driven steel pipe base on the static behavior of plastic greenhouse (PG). To promote the time and cost efficiency of the assembly process, each cross-linking connections of space arch type grid that consists of rafter and purlin is linked with steel-wire buckles, and each end of the rafters was driven directly to the ground to support the PG structure. However, in the design process, cross-linking connections and bases are idealized by being categorized as fully rigid or frictionless pinned, which does not appropriately reflect actual conditions. This study takes a full-scale loading test of PG and analyzes the effect of member cross-linking connections and driven steel pipe base on the behavior of a structure. The analysis provided a basis for determining the rigidity factor of member cross-linking nodes needed for finite element analysis, and the reliability of the result regarding the static behavior of PG.

The Characteristics analysis of a Flux-lock Type Fault Current Limiter according to the Winding Directions for Power Grid (전력계통 적용을 위한 결선방향에 따른 자속구속형 한류기의 특성 분석)

  • Lee, Mi-Yong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5879-5884
    • /
    • 2013
  • With the rapid industrialization and economical development, the electricity demands of the industrial facilities and densely populated large cities are continuing to increase in Korea. The increase in the power consumption requires the extension of power facilities, but it is difficult to secure spaces for equipment installation in the limited space of urban areas. In addition, the 154 kV or 345 kV transmission systems in Korea has a short transmission distance, and are connected to one another in network structures that ensure the high reliability and stability of power supply. This structure reduces the impedance during the fault in power system, and increases the magnitude of in the short circuit fault current. The superconducting fault current limiter (SFCL) was devised to effectively address these existing problems. The SFCL is a new-concept eco-friendly protective device that ensures fast operation and recovery time for the fault current and does not need additional fault detection devices. Therefore, many studies are being conducted around the world. In this paper, based on the wiring method the initial fault current characteristics, current limiting characteristics, according to the incident angle and the change in inductance current limiting characteristics were analyzed in a multifaceted methods.