Development, Implementation and Experimentation on a dSPACE DS1104 of a Direct Voltage Control Scheme

  • Hmidet, Ali;Dhifaoui, Rachid;Hasnaoui, Othman
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.468-476
    • /
    • 2010
  • This paper proposes and develops a new direct voltage control (DVC) approach. This method is designed to be applied in various applications for AC drives fed with a three-phase voltage source inverter (VSI) working with a constant switching time interval as in the standard direct torque control (DTC) scheme. Based on a very strong min(max) criterion dedicated to selecting the inverter voltage vector, the developed DVC scheme allows the generation of accurate voltage forms of waves. The DVC algorithm is implemented on a dSPACE DS1104 controller board and then compared with the space vector pulse width modulation technique (SVPWM) in an open loop AC drive circuit. To demonstrate the efficiency of the developed algorithm in real time and in closed loop AC drive applications, a scalar control scheme for induction motors is successfully implemented and experimentally studied. Practical results prove the excellent performance of the proposed control approach.

An Improved SVPWM Control of Voltage Imbalance in Capacitors of a Single-Phase Multilevel Inverter

  • Ramirez, Fernando Arturo;Arjona, Marco A.
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1235-1243
    • /
    • 2015
  • This paper presents a modified Space Vector Pulse Width Modulation Technique (SVPWM), which solves the well-known problem of voltage imbalance in the capacitors of a single-phase multilevel inverter. The proposed solution is based on the measurement of DC voltage levels at each capacitor of the inverter DC bus. The measurements are then used to adjust the size of the active vectors within the SVPWM algorithm to keep the voltage waveform sinusoidal regardless of any voltage imbalance on the DC link capacitors. When a voltage deviation exceeds a predetermined hysteresis band, the correspondent voltage vector is restricted to restore the voltage level to an acceptable threshold. Hence, the need for external voltage regulators for the voltage capacitors is eliminated. The functionality of the proposed algorithm is successfully demonstrated through simulations and experiments on a grid tied application.

Decoupled Control of Doubly Fed Induction Machine Fed by SVM Matrix Converter

  • Dendouga, Abdelhakim;Abdessemed, Rachid;Bendaas, Mohamed Lokmane
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.491-498
    • /
    • 2008
  • In this paper a decoupled control of a doubly-fed induction machine(DFIM) feed by a matrix converter is presented. It provides a robust regulation of the stator side active and reactive powers by the direct and quadratic components of the stator current vector, presented in a line-voltage-oriented reference frame. In this case, the stator windings are directly connected to the line grid, while the rotor windings are supplied by this later through a matrix converter controlled by a space vector modulation technique. The proposed solution is suitable for both energy generation and electrical drive applications with restricted speed variation range.

출력 상전압을 이용한 멀티-캐리어 PWM 기법의 간단한 고조파 분석 방법 (The Simple Harmonic Analysis Method of the Multi-Carrier PWM Techniques by Using the Output Phase Voltage in the Multi-Level Inverter)

  • 김준성;김태진;강대욱;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.352-360
    • /
    • 2003
  • This paper deals with a simple method in order to analyze and compare the harmonic characteristics in the multi-level inverter. Generally, the magnitude of harmonic components becomes different according to the multi-carrier Pulse Width Modulation(PWM) techniques, the modulation index($M_i$) and the switching frequency The previous papers analyzed the harmonic characteristics from the viewpoint of the space voltage vector. Hence, the calculation of the harmonic vector becomes more difficult and complex in 4-level or over 5-level. However, the proposed method has reduced an amount of calculation and simplified the process of it, using the relationship between the reference voltage and the output phase voltage to the load neutral point. It is applied to the 5-level cascade inverter and the harmonic characteristics for each multi-carrier PWM technique are compared through the simulation.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

전압제어 유도 전동기를 위한 최적 PWM 스위칭 방법 (An Optimized PWM Switching Strategy for an Induction Motor Voltage Control)

  • 한상수;추순남
    • 한국정보통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.922-930
    • /
    • 2009
  • 유도 전동기를 전압 제어하기 위한 최적 PWM 스위칭 방법을 제시하려한다. 전압 인버터의 공간 벡터 변조 방식은 DC-버스 이용을 향상시키고 정류 손실을 감소시키기 때문에 디지털 구현의 경우 특히 선호하는 PWM 방법이다. 유도 전동기 전압 제어를 위한 최적 PWM 스위칭 방법은 제시한 최적 PWM 알고리즘을 사용하여 두 개의 활성 전압 벡터(active voltage vector)와 하나의 영 전압 벡터(zero voltage vector)로 구성하였다. 선택된 스위칭 순차 열은 변조 지수(modulation index)와 운송파(carrier wave) 주기의 함수로 정의 된다. 순차 열은 인버터 스위칭 손실과 전류 리플 값을 기준으로 사용하여 선택된다. 실험 결과 중 저 전력용으로 사용할 경우 스위칭 주파수를 증가시킴에 따라 고조파 왜곡이 감소하고 동특성이 좋아짐을 확인할 수 있었다.

인버터 폴트 (B4) 환경 하에 토크리플 절감을 위한 개선된 변조방식 (Improved PWM for reducing torque ripple in PMSM with B4 inverter)

  • 박진식;정신명;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.292-294
    • /
    • 2006
  • This paper presents a study on the use of improved space-vector modulation of VSI employing only four switches, four body diodes. Different switching sequence strategy for vector control for inverter fault mode are described. The influence of different switching patterns at same modulation index and improved PWM method is proposed. The proposed PWM is compared with conventional PWM. Simulation and experimental results are presented.

  • PDF

공간전압벡터 PWM을 이용한 컨버터/인버터 시스템에서의 커먼 모드 전압 펄스 제거 (Elimination of a Common Mode Voltage Pulse in Converter/Inverter System Modifying Space-Vector PWM Method)

  • 이현동;이영민;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.89-96
    • /
    • 1999
  • This paper proposes a common-mode voltage reduction method base on SVPWM(Space-Vector Pulsewidth Modulation) in three phase PWM converter/inverter system. By shifting the active voltage vector of inverter and aligning this to the active vector of converter, it is possible to eliminate a common-mode voltage pulse in one control period. Since the proposed PWM method maintains the active voltage vector, it does not affect the control performance of PWM converter/inverter system. Without any extra hardware, overall common mode voltage dv/dt and conrresponding leakage current can be reduced to two-third of the conventional three phase symmetric SVPWM scheme.

  • PDF

브리지형 공진 AC 링크 스너버 방식을 이용한 3상 정현파 소프트 스위칭 PWM 인버터 (Three Phase Sinewave Soft-switching PWM Inverter using Bridge Type Resonant AC Link Snubber)

  • 김정식;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.58-62
    • /
    • 2017
  • This paper presents a novel prototype of the resonant AC link snubber circuit for the three-phase sinwave soft-switching PWM inverter. In principle, its operating principle is described, and the performance evaluations of the specific instantaneous space voltage modulated three-phase sinewave soft switching PWM inverter incorporating a resonant AC link snubber is illustrated, and evaluated, introducing the specific space voltage vector modulation implementation. It is conferred that the validity of three-phase soft-switching inverter treated here in setup experiment.

공간벡터 PWM에서 과변조시 출력전압의 선형화 및 고조파 분석 (Linearization and harmonic analysis of output voltages in overmodulation range of space vector PWM)

  • 이지명;이동춘
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.118-124
    • /
    • 1998
  • This paper describes a relationship of a space vector PWM and a sinusoidal PWM and presents that the space vector PWM can produce linearly the output voltage to the unity MI(modulation index). At first, reference angles and holding angles are derived from expanding a Fourier series of the reference voltage waveform and then the angles are used for the inverter switching to linearize transfer characteristics of the inverter. In addition, the harmonic components of the output voltage are analyzed and on-line control is shown to be feasible by approximating in piecewise-linearization the reference and holding angles versus the MI. In V/f control of the induction motor, it is verified by the experiment that the motor current is changed smoothly for the variation of the inverter input voltage and the change of the reference voltage.