• Title/Summary/Keyword: source-basin

Search Result 365, Processing Time 0.027 seconds

Performance of Hybrid Solar Still Under Operating Conditions (하이브리드 태양열 해수담수기의 운전 조건별 성능실험)

  • Yeo, Se Dong;Lim, Byung Ju;Yu, Sang Seok;Chung, Kyung Yul;Park, Chang Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.511-519
    • /
    • 2017
  • In this study, we have performed tests to improve the productivity of hybrid solar stills, which can be operated by solar thermal energy and/or waste heat of exhaust gas from electrical generators. The experimental apparatus is a hybrid solar still with a $1m{\times}2m$ collecting area, which consists of a conventional simple solar still and a vertical multi-effect diffusion(MED) section. The experiments were conducted under various operating conditions, with two identical hybrid solar stills, using solar radiation as the energy source. The results of the tests showed that the yield of the hybrid solar still depends on the various operating conditions. Insulation at the side glasses and a lower basin seawater level increased the productivity of the hybrid solar still. Reflecting fins with less than 47% reflectivity unexpectedly decreased the total productivity. However, the various feeding flow rate of the seawater into MED part did not show clear effects on productivity in the tested range.

A Study on the Development of GIS Based Mitigation Scenario Support System Using QUAL2E Model for TMDL (TMDL 지원을 위한 QUAL2E 모델을 이용한 GIS기반의 삭감시나리오 작성 지원시스템 개발에 관한 연구)

  • Lee, Chol-Young;Kim, Kye-Hyun;Lee, Hyuk;Ryu, Kwang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.177-188
    • /
    • 2012
  • This study was mainly focused on the development of GIS based decision support system to easily make mitigation scenarios and to conveniently simulate water quality for TMDL. The study area was the 31km section of upper Sapgyo stream in Geum river basin, and QUAL2E model was adopted. GIS DB was built through the collection of the data which includes point/non-point source attributes and various thematic maps. The amounts of discharged loads of BOD, T-N and T-P from unit watershed were estimated respectively. Finally, the system, which can operate water quality simulation through simply modifying their values, was developed. The hypothetical three mitigation scenarios were applied, thereby the most efficient mitigation scenario could be chosen by comparison of the results based on GIS. Therefore, it is expected that the developed system can facilitate the decision makers to select the best alternative through the analysis of the available BMPs. Also, it can be used to develop new scenarios using different methods and algorithms. In the future, more study need to be made to enhance its applicability in the perspective of developing mitigation scenarios through the management of individual pollutant sources and extending study areas.

Quantitative Assessment of Nonpoint Source using the Basin Model (유역모형을 이용한 비점오염원의 정량적 평가)

  • Kwon, Heon-Gak;Kim, Dong-Il;Lee, Jea-Woon;Han, Kun-Yeun;Cheon, Se-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.141-141
    • /
    • 2012
  • 비점오염물질은 강우 시 유출되기 때문에 일간, 계절 간 유출량 변화가 대단히 크게 나타나며, 기후, 지형, 토지이용, 토양 등과 지역적인 특성과 유역 형상에 따라 변화되므로 비점오염원 유출량에 대한 정량화를 위해서는 강우지속시간동안 정확한 수질과 유량에 대한 측정 자료가 요구된다. 따라서 본 연구에서는 비점오염물질에 대해 현장 모니터링 및 현장 실측 관련 기존 연구자료 수집을 통해 중분류 토지피복분류별 원단위를 산정하였다. 또한 특정 유역에 중분류 토지피복 분류별 산정된 원단위를 적용하여 유역기반의 비점오염부하량을 산정 하였다. 대상 유역에 해당하는 하천 말단에서의 실측 자료를 활용하여 유역모형을 구축하고, 강우를 입력 자료로 하여 비점오염 물질별 부하량을 모의 산정하였다. 유역모형으로 HSPF(Hydrologic Simulation Program - Fortran)을 실제 대상유역에 적용하였고, 이에 따른 모의 결과를 실측치와 비교하여 부하량을 산정하였다. 이렇게 모의 산정된 부하량은 실측자료를 기반으로 산정된 원단위의 적용에 따른 부하량과 비교 검토하여 유역에 대한 비점오염원 부하량 산정 시 모형의 적용 가능성을 평가하였다. 본 연구에 적용된 대상유역은 동천유역으로 병성천의 주요 지류로서 유역의 상단에 위치하고 있다. 중분류 토지피복 중 공업지역, 교통지역, 과수원재배지, 비닐하우스재배지, 기타재배지에 대해서는 2008년부터 2010년까지 모니터링을 실시하였고, 이외의 중분류 토지피복에 대한 결과는 수계별 현재까지 진행되고 있는 환경기초조사사업 중 '주요 비점오염원 유출 장기 모니터링'사업의 자료를 활용하였다. 동천유역의 비점오염원 발생부하량을 산정한 결과, BOD 부하량은 대지의 경우 391.4 kg/day로서 중분류 군으로 구분한 결과에 비해 높게 산정되었다. T-N, T-P 발생부하량도 토지피복군이 대분류에서 중분류로 변화됨에 따라 부하량의 차이가 발생 하였다. 또한 동천유역에 대해 구축된 HSPF 모형의 적합도를 시기별 4개의 Case로 구분하여 평가해 보았는데 그 결과, 모형 모의치의 실측치에 대한 적합도가 높게 평가 되었다. 현재 특정 지역에 편중되어 조사되고 있는 중분류 토지피복을 조사 기관간의 교차 조사를 통해 지역적 제한성을 낮추고, 중분류에 속하는 세부피복지점을 확대하여 모니터링 지점의 다양성을 확보하여야 할 것으로 판단된다. 이와 동시에 한시적인 조사가 아닌, 장기간에 걸쳐 연구가 진행 될 경우 원단위에 대한 현재의 불확실성 및 제한성을 줄일 수 있을 것으로 판단되므로, 이러한 기초 자료 확보에 대한 장기적인 투자와 노력이 수반될 시 우리나라에 대표적으로 적용할 수 있는 비점오염원 원단위가 산정될 것으로 생각되며, 이러한 기틀이 마련되어야 비점오염원에 대한 적절한 유역관리방안을 수립할 수 있을 것으로 생각된다.

  • PDF

Priority assessment and estimation of annual power generation for potential development site of hydroelectric dam in North Korea (북한지역 수력발전댐 개발가능지점에 대한 연간가능발생전력량 분석 및 개발 우선순위 평가)

  • Kwon, Minsung;Kim, Tae-Woong;Ahn, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.929-939
    • /
    • 2018
  • In North Korea, hydropower which occupies about 63% of power generation is a major electric power source, and North Korea has many advantages in the geographical for developing hydroelectric power. In this study, Information on the basin and dam capacity for 33 potential development site of hydroelectric dam was analyzed using DEM, and potential annual power generation was estimated by applying results of long-term runoff simulation with MWSWAT model for recent 30-year. The potential annual power generation at 33 dam was estimated to be about 28% of the current hydroelectric power in North Korea. In addition, a priority of dam development in each province was assessed by estimating the scale of an industry and prospecting the population change in the future. And a priority for dam development within the province was estimated based on the dam capacity and the potential annual power generation. The priority of each province was ranked in order of Pyeongannamdo, Hamgyungnamdo, Hamgyungbukdo, Hwanghaebukdo, Pyeonganbukdo, Jagangdo, Ryanggangdo, Hwanghaenamdo, and Gangwondo. The results of this study can be used as an initial review data for advancing to hydropower development project in North Korea.

Analysis of sound power level of high-noise construction machinery excavator (고소음 건설기계 굴삭기의 소음도 현황 분석)

  • Park, Hyung-Kyu;Jung, Joon Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.240-246
    • /
    • 2019
  • The noise generated by construction machinery operating at construction sites is a major cause of environmental disputes with nearby residents. To reduce construction site noise, low noise construction machinery and low noise methods are recommended to be used first. In addition, the possible noise should be predicted and preventive measures suitable for the noise source should be taken. This study analyzed the sound power level of an excavator, which is used most frequently at construction sites. The sound power level of 297 excavators sold in Korea after 2008 were analyzed and the sound power level was classified according to the type, output (kW), and production site of the excavator engine based on the measured data. As a result, the sound power level decreased by 1 dBA depending on the change in engine type and the sound power level increased by approximately 3 dB (A) when the engine output was doubled. In addition, the sound power level was low in small-sized products of less than 55 kW for overseas products and medium and small-sized products of 55 to 104 kW for domestic products.

Analysis of Load Duration Curve Using Long Time Flow Measurement Data of Kyeongancheon (장기간 유량측정 자료를 이용한 경안천의 부하지속곡선 특성)

  • Noh, Changwan;Kwon, Phil-Sang;Jung, Woo-Seok;Lee, Myung-Gu;Cho, Yong-Chul;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.1
    • /
    • pp.35-48
    • /
    • 2019
  • Long term flow measurement and water quality analysis data need to determine the target and allowable load for each basin in Total Water Pollution Load Management System (TWPLMS). The Load Duration Curve (LDC) is analyzed the relationship between flow data and water quality, and evaluates the pollutant load characterization by flow conditions. LDC of Kyeongancheon is created by the Flow Duration Curve (FDC) that was analyzed 8-day interval measured flow data from 2006 to 2015 and numeric water quality target in Kyeongancheon. As a result of this study, it is necessary to manage the point source pollutant because the numeric water quality target is not satisfied in the low flows. Also the numeric water quality target has been exceed for four months from March to June of the year and continuous and systematic watershed management is required to satisfy the numeric water quality target.

Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Jeong, Myungsuk;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

Water Management Plan for the Nakdong River Using TOC and COD (총유기탄소와 화학적산소요구량을 이용한 낙동강 물관리 방안)

  • Bo Eun Kim;Meea Kang;Gyo-Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2023
  • The Nakdong river is both a natural resource crucial to underwater ecosystems and a water source for its basin's residents. Industrial wastewater and domestic sewage must meet the relevant standards for discharged water before they can flow into the river. The correlation between old and new measures of organic matter was examined using water quality data from 50 monitoring locations in the main stream of the Nakdong river. The coefficient of determination (R2) for total organic carbon (TOC), the new measure of organic matter, and chemical oxygen demand (COD), the old measure of organic matter, in the main stream of the Nakdong river was 0.6134, indicating high correlation. Water quality at each location assessed using TOC and COD showed disparities that cannot be ignored: quality appeared higher when evaluating the main stream of the Nakdong river using TOC instead of COD. Therefore, there remains a need to review water quality ratings based on TOC; continuous monitoring of COD is also required. In addition, the cause of the difference should be clearly identified to help assess artificial sources of pollution and natural factors affecting organic matter. Water management of the Nakdong river will then be possible using the water quality rating.

The Development of Tidal Power System Can be Installed in Existing Dykes - The Open Channel Experimental Verification (기존 방조제에 설치 가능한 조력발전 장치 개발 - 개수로 현장실험 검증)

  • HyukJin Choi;Dong-Hui Ko;Nam-Sun Oh;Shin Taek Jeong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.1
    • /
    • pp.13-21
    • /
    • 2023
  • As problems such as difficulties in securing stable energy resources and global warming due to the emission of greenhouse gases due to the use of fossil fuels have emerged, interest in the development of renewable energy is increasing. Since the tidal phenomenon has a regularity that occurs regularly with a certain period, it is possible to predict accurately in advance, which has a advantage in terms of energy recovery. Therefore, various methods have been devised to utilize the tide as an energy source. Tidal power using barrages is a representative method that is widely operated, but the promotion of tidal power generation projects is being delayed or stopped due to the decrease in the level of water in the tidal basin, changes in water quality and in the ecosystem. In this study, a field experiment was conducted to develop and verify the performance of a tidal power device applicable to sea areas where dykes are already installed. As a result of carrying out four cases of experiments using two water tanks, pipe lines, open channels, weirs, and water turbine and generator, the possibility of developing a power generation system capable of 10 kW output or more and 60% efficiency or more was confirmed. These research results can be used for small-scale tidal power by utilizing the existing dykes.

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.