• Title/Summary/Keyword: source water

Search Result 4,425, Processing Time 0.036 seconds

A Study on Optimal Operation of Summer Season Cooling System with Numbers of Heat Pumps (다수의 히트펌프로 구성된 냉난방시스템에서 하절기 히트펌프의 최적운전에 관한 연구)

  • Shin, Kwan-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.35-40
    • /
    • 2006
  • Heat-pump system has a special feature that provides heating operation in winter season and cooling operation in summer season with a single system. It also has a merit that absorbs and makes use of wastewater heat, terrestrial heat, and heat energy from the air. Because heat-pump system uses midnight electric power, it decreases power peak load and is very economical as a result. By using the property that energy source is converted to low temperature when losing the heat, high temperature energy source is used to provide heating water and low temperature energy source is used to provide cooling water simultaneously in summer season. This study made up a heat-pump system with 4 air heat sources and a water heat source and implemented the optimal operation algorithm that works with numbers of heat pumps to operate them efficiently. With the heat-pump system, we applied it to cooling and heating operation in summer season operation mode in a real building.

Economical Assessment of Wastewater Treatment Facilities in Leather Tanning and Finishing Industry (가죽, 모피 가공 및 제조업 폐수처리시설의 경제성 평가)

  • Kim, Jaehoon;Yang, Hyung jae;Kwon, Oh sang;Lee, Sung jong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.131-137
    • /
    • 2007
  • Industrial wastewater management guideline and evaluation model of Best Available Technologies for the leather tanning and finishing industry was developed as an economical evaluation model using evaluation of BAT including economical evaluation combined with cost analysis model and cost annualization model in considering of economical factors and non-water environmental factors. It was verified that approximately 10% will be increased annually to modify conventional treatment process ($3,700m^3/d$) of J leather wastewater treatment plant to advanced process of K leather wastewater treatment plant.

Assessing Impact of Non-Point Source Pollution by Management Alternatives on Arable Land using AGNPS Model (AGNPS 모형을 이용한 농경지 관리대안에 따른 비점오염 저감효과 분석)

  • Lee, Eun-Jeong;Kim, Hak-Kwan;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1008-1013
    • /
    • 2007
  • The objectives of the paper were to identify appropriate best management practices (BMPs) for reducing nonpoint source (NPS) pollutant loadings and to simulate the effects of the application of the several BMP scenarios on the study watershed using Agricultural Nonpoint Source (AGNPS) model. AGNPS model was calibrated and validated for runoff, sediment yield, and nutrient components using the observed hydrologic and water quality data. The simulated runoff, sediment, and nutrient components were well agreed with observed data. The validated AGNPS was applied to estimate the NPS pollution removal efficiency for BMP scenarios which were selected considering the pollutant characteristics of the study watershed.

  • PDF

Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System (복합 열원 공조시스템의 최적 제어 알고리즘)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

Improvement of Quality in Treated Water by the pH Adjustment of Raw Water (원수 pH 조정에 의한 정수 수질 개선)

  • Jeong, Gwan-Jo;Lee, Kyeong-Woo;Kim, Hyun-Hee;Jeong, Eui-Sun;Park, Hyeon;Han, Sun-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.469-476
    • /
    • 2010
  • The purpose of the study is to find ways to decrease turbidity and residual aluminum by improving the efficiency of coagulation process through controlling the pH of the source water with $CO_2$ when the pH increases by algal bloom or by the characteristics of the source water. Water quality parameters were monitored before and after $CO_2$ addition in February, March, April, and December, when the pH of the source water is over 8.0 and constant regardless of day and night. Water quality parameters closely related with evaluation of treated drinking water quality were monitored in detail, e.g. aluminum, turbidity, particle counts, TOC, THMs, 2-MIB, and geosmin. According to the results, inorganic water quality parameters such as turbidity, particle counts, and aluminum were decreased due to improved efficiency of the coagulation process. It was concluded that the pH of the water in the arrival basin must be controlled below 7.4 by adding $CO_2$ when the pH of the source water increasing. By controlling pH with $CO_2$, the water quality could be maintained within the drinking water quality goal of Seoul City (<30 particle/mL of particle count, <0.05 NTU of turbidity and <0.02 mg/L of aluminum). The change of the pH could not affect the concentrations of DBP's (e.g., THMs, CH, and HAAs) and taste/odor causing compounds (e.g., 2-MIB and geosmin). 2-MIB and geosmin were affected more by their initial concentrations in the source water.

A Study on the Optimal Position for the Secondary Neutron Source in Pressurized Water Reactors

  • Sun, Jungwon;Yahya, Mohd-Syukri;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1291-1302
    • /
    • 2016
  • This paper presents a new and efficient scheme to determine the optimal neutron source position in a model near-equilibrium pressurized water reactor, which is based on the OPR1000 Hanul Unit 3 Cycle 7 configuration. The proposed scheme particularly assigns importance of source positions according to the local adjoint flux distribution. In this research, detailed pin-by-pin reactor adjoint fluxes are determined by using the Monte Carlo KENO-VI code from solutions of the reactor homogeneous critical adjoint transport equations. The adjoint fluxes at each allowable source position are subsequently ranked to yield four candidate positions with the four highest adjoint fluxes. The study next simulates ex-core detector responses using the Monte Carlo MAVRIC code by assuming a neutron source is installed in one of the four candidate positions. The calculation is repeated for all positions. These detector responses are later converted into an inverse count rate ratio curve for each candidate source position. The study confirms that the optimal source position is the one with very high adjoint fluxes and detector responses, which is interestingly the original source position in the OPR1000 core, as it yields an inverse count rate ratio curve closest to the traditional 1/M line. The current work also clearly demonstrates that the proposed adjoint flux-based approach can be used to efficiently determine the optimal geometry for a neutron source and a detector in a modern pressurized water reactor core.

Numerical Analysis of Impact Forces and Entry Behaviors of the High Speed Water Entry Bodies (고속으로 입수하는 물체에 대한 충격량 및 입수 거동 해석)

  • Kim Y. W.;Park W. G.;Kim C. S.
    • Journal of computational fluids engineering
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • The numerical methodology for computing tile impact forces and water entry behaviors of high speed water entry bodies was been developed. Since the present method assumed the impact occurs within a very short time interval. the viscous effects do not have enough time to play a significant role in the impact forces, that is, the flow around a water-entry object was assumed as an incompressible potential flow and is solved by the source panel method. The elements fully submerged into the water are routinely treated, but the elements intersected by the effective planar free surface are redefined and reorganized to be amenable to the source panel method. To validate the present code, it was applied to disk, cone and ogive model and compared with experimental data. Good agreement was obtained. The water entry behavior such as the bouncing phenomena from the free surface was also simulated using the impact forces and two degree of freedom dynamic equation. Physically acceptable results were obtained.

  • PDF

Waterborne viruses in drinking water in Korea: survey 1999 for enteric virus contamination in treated water and its source water

  • Rhie KT;Yoon JD;Chung HM;Kim HS;Jeong YS
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.142-142
    • /
    • 2001
  • A national survey for enteric virus contamination in treated water and its source water was performed from March to November 1999. The water samples were subjected to virus filtration at the major water plants producing over 10$^5$ tons treated water per day. Twenty surveyed sites encompass most of heavily populated residential area except for Seoul and Pusan. (omitted)

  • PDF

Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics (이중 열원 히트펌프 시스템의 난방 성능과 운전 특성)

  • Lim, Hyojae;Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.