• 제목/요약/키워드: source tracking

검색결과 328건 처리시간 0.032초

차량 부밍소음의 청감 변화 인지를 위한 주파수 역치 (Difference Limen for Just Noticeable Change of Booming Sensation in Frequency)

  • 신성환;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.621-624
    • /
    • 2005
  • Among many auditory feelings for the vehicle interior noise, booming is considered as the most important nuisance to the passenger and developer. Because the main source of booming noise is a power train system including engine, in general, it consists of tonal components related to fundamental engine rotation and its harmonics including the firing frequency. Therefore, it is demanded to extract the effective tonal components only by using pitch extraction algorithm based on the place theory enable to find aurally relevant tonal components. However, there is a difference between booming sensation and pitch perception according to frequency change of tonal component. In this study, subjective listening test using a tracking method was performed to find the difference limen for just noticeable change of booming sensation in frequency. 20 Koreans and 10 Japanese were participated in this test and the results obtained from Koreans and Japanese were compared with each other. Finally, 5Hz was determined as the difference limen for just noticeable change of booming sensation in frequency, and by applying this value to booming analysis using pitch concept, it was confirmed that the degree of prediction of booming sensation was improved.

  • PDF

PV 시스템을 이용만 단상유도전동기의 벡터제어 (Vector Control of Single Phase Induction Motor using PV System)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.49-58
    • /
    • 2009
  • 본 논문은 최대전력점추적을 하는 PV 시스템을 이용한 점핑시스템 구동을 위한 단상유도전동기의 벡터제어를 제시한다. 펌핑시스템은 벡터제어에 의한 원심 펌프를 구동하는 가변속 단상유도전동기를 사용한다. DC-DC 컨버터를 이용한 MPPT는 다양한 일사량에 따라 최대 전력을 추적하기 위해 듀티 사이클을 제어한다. 듀티 사이클은 자속을 발생시키는 전류($i_{ds}$)와 직접적인 관계가 있다. 벡터제어 인버터는 CC-VSI를 사용한다. 시뮬레이션 결과는 일사량 변화에 따른 전압($V_{dq}$), 전류($I_{dq}$), 전동기 속도, 토크 등의 성능 및 특성을 나타낸다.

자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법 (Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines)

  • 권국민;서용석
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

계통 연계형 태양광발전시스템을 위한 POS MPPT 운전특성 최적화 기법 (Optimization technique of POS MPPT operational characteristics for grid-connected PV generation system)

  • 박상수;김상용;장성재;김경훈;서효룡;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1064_1065
    • /
    • 2009
  • PV (Photovoltaic) power generation system has been widely studied as a clean and renewable power source. Tracking the MPP (maximum power point) of a PV array is usually an essential part of a PV system. This paper describes POS (Photovoltaic Output Sensorless) MPPT method and optimization technique of its operational characteristics for grid-connected PV generation system. A DC-DC converter has been used to step-up the PV voltage and DC-AC converter has been used for connecting the system to the grid. Optimization technique has been implemented to optimize the current and voltage controller gain parameters and duty ratio increment of DC-DC converter. Simulation results reveal that the proposed control has better response.

  • PDF

태양광어레이 최적화에 의한 단위 부지면적당 발전량 개선 (Improvement of generation capacity per unit site area by the optimization of photovoltaic array)

  • 김의환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.109.2-109.2
    • /
    • 2011
  • A photovoltaic system is getting the spotlight for a environment-friendly energy source. But its location is limited because a lot of land is necessary for photovoltaic arrays. Nevertheless, its dissemination is rapidly increasing more than 40 % every year and exceeded about 400 MW in 2009. The radical growth of a photovoltaic system aggravated a lack of sites, so that forests and farmland were destroyed. It is demanded to make use of a vacant lot or little piece of land for the way to solve the lack of sites and improve the location requirements for a photovoltaic system. General photovoltaic arrays are consist of a single layer structure and needs enough separation distances to maximize the amount of solar radiation and to eliminate influences by the shadow of other arrays. So that a large amount of land is required for the site. The solar cell arrays with long separation distances can not be placed in a small vacant lot and its site application efficiency is low. This study optimized photovoltaic arrays as multilayered structure with movable sleeves for the efficient photovoltaic in a small site. The existing photovoltaic arrays with a single layer structure were fixed or tracking systems. In this experimental equipment, photovoltaic arrays attached to the multilayers have rectilinear movement and rotary motion using sleeves. Therefore, shadow influences were removed and the generation capacity was improved. On the simulation result, generation increased by about 30% in the same site considering shadow influences and so on.

  • PDF

Identifying Suspended Particulate Matters in an Urban Coastal System: Significance and Application of Particle Size Analysis

  • Ahn, Jong-Ho
    • Environmental Engineering Research
    • /
    • 제17권3호
    • /
    • pp.167-174
    • /
    • 2012
  • In situ particle size spectra are obtained from two sequent cruises in order to evaluate the physical consequences of suspended particulate matters caused by episodic storm runoff from the Santa Ana River watershed, an urbanized coastal watershed. Suspended particles from various sources including surface runoff, near-bed resuspension, and phytoplankton are identified in empirical orthogonal function (EOF) analysis and an entropy-based parameterization (Shannon entropy). The first EOF mode is associated with high turbidity and fine particles as indicated by the elevated beam attenuation near the Santa Ana River and Newport Bay outlets, and the second EOF mode explains the suspended sediment dispersal and particle coarsening at the near-surface plume. Chlorophyll particles are also distinguished by negative magnitudes of the first EOF mode, which is supported by the relationship between fluorescence and beam attenuation. The integrated observation between the first EOF mode and the Shannon entropy index accentuates the characteristics of two different structures and/or sources of sediment particles; the near-surface plumes are originated from runoff water outflow, while the near-bottom particles are resuspended due to increased wave heights or mobilizing bottom turbidity currents. In a coastal pollution context, these methods may offer useful means of characterizing particle-associated pollutants for purposes of source tracking and environmental interpretation.

Bearing Estimation of Narrow Band Acoustic Signals Using Cardioid Beamforming Algorithm in Shallow Water

  • Chang, Duk-Hong;Park, Hong-Bae;Na, Young-Nam;Ryu, Jon-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • 제21권2E호
    • /
    • pp.71-80
    • /
    • 2002
  • This paper suggests the Cardioid beamforming algorithm of the doublet sensors employing DIFAR (directional frequency analysis and recording) sensor signals in the frequency domain. The algorithm enables target bearing estimation using the signals from directional sensors. The algorithm verifies its applicability by successfully estimating bearings of a target projecting ten narrow-band signals in shallow water. The estimated bearings agree very well with those from GPS (global positioning system) data. Assuming the bearings from GPS data to be real values, the estimation errors are analyzed statistically. The histogram of estimation errors in each frequency have Gaussian shape, the mean and standard deviation dropping in the ranges -1.1°∼ 6.7°and 13.3∼43.6°, respectively. Estimation errors are caused by SNR (signal to noise ratio) degradation due to propagation loss between the source and receiver, daily fluctuating geo-magnetic fields, and non-stationary background noises. If multiple DIFAR systems are employed, in addition to bearing, range information could be estimated and finally localization or tracking of a target is possible.

RF Power Detector for Location Sensing

  • Kim, Myung-Sik;Kubo, Takashi;Chong, Nak-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1771-1774
    • /
    • 2005
  • Recently, RFID has become popular in the field of remote sensing applications. Location awareness is one of the most important keys to deploying RFID for advanced object tracking. Generally, multiple reference RF stations or additional sensors are used for the location sensing with RFID, but, particularly in indoor environments, spatial layout and cost problems limit the applicability of those approaches. In this paper, we propose a novel method for location sensing with active RFID systems not requiring the need for reference stations or additional sensors. The system triangulates the position of RF signal source using the signal pattern of the loop antenna connected to the power detector. The power detector consists of a signal strength detector and a signal analysis unit. The signal analysis unit indicates the signal strength and serial number using the signal from the strength detector, and provides the direction of the signal to the application target. We designed three different signal analysis units depending on the threshold type. The developed system can sense the direction to the transponder located over 10 m away within the maximum error of $5^{\circ}$. It falls within a reasonable range in our normal office environment.

  • PDF

동적 대역폭 할당을 이용한 ABR 트래픽 제어 방식에 관한 연구 (A Study on the ABR Traffic Control Mechanism using Dynamic Bandwidth Allocation)

  • 류호용;박권철;박광채
    • 한국통신학회논문지
    • /
    • 제24권12B호
    • /
    • pp.2275-2282
    • /
    • 1999
  • 효율적인 ABR 트래픽 제어를 위해서 가용 대역폭 정보에 의한 대역폭 할당이 이루어져야 한다. 그런, 현재 제안되고 있는 가용 대역폭 정보의 추정은 통계적인 값을 이용하여 이루어지기 때문에 버스트한 크기를 가지고 들어오는 트래픽을 고려한 동적 대역폭 할당이 어렵다. 본 논문에서는 효율적인 대역폭 할당을 위해서 출력 버퍼형 ATM 스위치에서 각 VC 접속에 대해서 단일 버퍼를 이용하는 Per-VC 큐잉과 가용대역폭을 측정하기 위한타이머 및 각 접속의 혼잡 상태를 파악하기 위한 제어기로 구성하였다. 제어기에서는 각 VC의 혼잡 상태를 검사하고, 타이머에서는 각 접속의 Backlogged 시간과 전체 링크 용량을 이용하여 현재 주기 동안의 사용대역폭을 구하고, 이 값을 송신원 측으로 전송하여 이 값에 의해서 동적으로 대역폭을 할당한다. 제안한 방법을 이용하여 통계적인 파라미터를 이용하지 않고, 현재 주기 동안 전송된 대역폭을 이용하여 다음 주기의 대역폭을 할당하여 개선된 링크 효율을 얻을 수 있다.

  • PDF

플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS (Flywheel Energy Storage UPS with Voltage Compensation)

  • 이기수;김중원;전태원;김인동;김흥근;이홍희;노의철
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.241-247
    • /
    • 2005
  • 본 논문에서는 플라이휠의 저장에너지를 이용한 다이나믹 무정전 전원장치를 제안하고 동작기능을 분석하였다. 배터리를 에너지 저장요소로 사용하고 있는 기존의 무정전 전원장치에 비해 플라이휠 방식의 무정전 전원장치는 수명이 길고, 효율이 높으며, 환경공해가 거의 없으며, 크기도 작고, 특히 유지보수 비용이 현저히 작다는 장점을 갖는다. 무정전 기능뿐 아니라 전압보상 기능도 갖는 시스템에 대한 동작특성을 해석하였으며, 순간정전 후 전압이 복귀되는 시점에서의 위상변동을 신속히 추종하는 특성도 살펴보았다. 시뮬레이션과 실험을 통해서 시스템의 유용성을 검증하였다.