• 제목/요약/키워드: source strength

검색결과 763건 처리시간 0.032초

Adaptive group of ink drop spread: a computer code to unfold neutron noise sources in reactor cores

  • Hosseini, Seyed Abolfazl;Afrakoti, Iman Esmaili Paeen
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1369-1378
    • /
    • 2017
  • The present paper reports the development of a computational code based on the Adaptive Group of Ink Drop Spread (AGIDS) for reconstruction of the neutron noise sources in reactor cores. AGIDS algorithm was developed as a fuzzy inference system based on the active learning method. The main idea of the active learning method is to break a multiple input-single output system into a single input-single output system. This leads to the ability to simulate a large system with high accuracy. In the present study, vibrating absorber-type neutron noise source in an International Atomic Energy Agency-two dimensional reactor core is considered in neutron noise calculation. The neutron noise distribution in the detectors was calculated using the Galerkin finite element method. Linear approximation of the shape function in each triangle element was used in the Galerkin finite element method. Both the real and imaginary parts of the calculated neutron distribution of the detectors were considered input data in the developed computational code based on AGIDS. The output of the computational code is the strength, frequency, and position (X and Y coordinates) of the neutron noise sources. The calculated fraction of variance unexplained error for output parameters including strength, frequency, and X and Y coordinates of the considered neutron noise sources were $0.002682{\sharp}/cm^3s$, 0.002682 Hz, and 0.004254 cm and 0.006140 cm, respectively.

Experimental observation and realistic modeling of initiation and propagation of the rock fracture by acoustic emission

  • Wang, Shu-Hong;Lee, Chung-In;Jeon, Seok-Won;Lee, Hee-Kwang;Tang, Chun-An
    • 한국암반공학회:학술대회논문집
    • /
    • 한국암반공학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.79-93
    • /
    • 2006
  • It is well known that acoustic emission (AE) is indicator of rock fracturing or damage as rock is brought to failure under the uniaxial compressive loads. In this paper, an experimental study on the source location of acoustic emission on the cylindrical specimens of granite under uniaxial compression test was made. The AE source location was made by measuring the six channel AE data. Comparing to this experiment, the numerical method is applied to model the initiation and propagation of fracture by AE using a numerical code, RFPA (Realistic Failure Process Analysis). This code incorporates the mesoscopic heterogeneity in Young's modulus and rock strength characteristic of rock masses. In the numerical models, values of Young's modulus and rock strength are realized according to a Weibull distribution in which the distribution parameters represent the level of heterogeneity of the medium. The results of the simulations show that RFPA can be used not only to produce acoustic emission similar to those measurements in our experiments, but also to predict fracturing patterns under uniaxial loading condition.

  • PDF

Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구 (A Study on Optimizing Energy Transfer of Capacitive Switching Antenna)

  • 김진만;방정주;허창수
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

펩타이드 질량 분석을 위한 전기 이온화 분사기의 제작 및 성능 평가 (Mass spectrometry analysis system with integrated micro electrospray ionization emitter for peptide detection)

  • 김민수;주황수;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1534-1535
    • /
    • 2007
  • This paper describes a novel microfluidic device with a microfabricated electrospray source for a sheathless electrospray ionization interface to a mass spectrometer. This electrospray ionization-mass spectrometry (ESI-MS) device consists of a triangular-shaped metal emitter, allowing the generation of an efficient electrospray for peptide detection, and microfluidic channels monolithically in a glass microchip. The performance of the proposed interface was evaluated by opimizing its experimental condition and spraying standard peptides. The spraying has high signal strength and stability, with a relative standard deviation of 2.9% and singly-charged and doubly-charged peaks of the peptides were successfully detected. The metal emitter source showed a good performance to be comparable to commercially available emitters in signal strength and stability.

  • PDF

A Novel Jamming Detection Technique for Wireless Sensor Networks

  • Vijayakumar, K.P.;Ganeshkumar, P.;Anandaraj, M.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권10호
    • /
    • pp.4223-4249
    • /
    • 2015
  • A novel jamming detection technique to detect the presence of jamming in the downstream direction for cluster based wireless sensor networks is proposed in this paper. The proposed technique is deployed in base station and in cluster heads. The proposed technique is novel in two aspects: Firstly, whenever a cluster head receives a packet it verifies whether the source node is legitimate node or new node. Secondly if a source node is declared as new node in the first step, then this technique observes the behavior of the new node to find whether the new node is legitimate node or jammed node. In order to monitor the behavior of the existing node and new node, the second step uses two metrics namely packet delivery ratio (PDR) and received signal strength indicator (RSSI). The rationality of using PDR and RSSI is presented by performing statistical test. PDR and RSSI of every member in the cluster is measured and assessed by the cluster head. And finally the cluster head determines whether the members of the cluster are jammed or not. The CH can detect the presence of jamming in the cluster at member level. The base station can detect the presence of jamming in the wireless sensor network at CH level. The simulation result shows that the proposed technique performs extremely well and achieves jamming detection rate as high as 99.85%.

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

양상태-단상태 변환 기반 잠수함 양상태 표적강도 해석 (Submarine bistatic target strength analysis based on bistatic-to-monostatic conversion)

  • 김국현;박성주;이근화;조대승
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.138-144
    • /
    • 2024
  • 본 논문에서는 잠수함 양상태 표적강도 해석을 위한 양상태-단상태 변환 기법을 제안하였다. 이 기법은 송신 음원이 수중 표적면에 의해 산란된 후 수신자에 도달하는 음파 전달 경로 길이를 산정하고, 이에 상응하는 가상 산란면을 생성함으로써, 수중 표적의 표적강도 문제를 양상태에서 단상태로 변환하는 방법이다. 변환된 단상태 표적강도 문제는 기 정립된 단상태 표적강도 수치 해석 기법을 활용하여 양상태 표적강도를 평가한다. 표적강도 표준모델로 활용되고 있는 BeTTSi에 대한 양상태 표적강도 해석을 수행하였으며, 그 결과는 경계 요소법과 키르히호프 근사에 의한 해석 결과와 비교하여 제안된 해석 기법의 신뢰성과 잠수함 표적강도 평가 도구로서의 실무 활용성을 확인하였다.

ISO 9613-2를 이용한 철도 환경소음 예측 모델 개선에 관한 연구 (Study on the improvement of prediction model for the railway environmental noise using ISO 9613-2)

  • 장승호;고효인;홍지영
    • 환경영향평가
    • /
    • 제26권1호
    • /
    • pp.11-26
    • /
    • 2017
  • 철도 소음의 환경영향평가 업무에 있어서 소음도에 대한 정확한 예측이 중요하지만, 국내에서는 overall 소음도의 거리별 측정을 통한 경험식이 근사적으로 이용되고 있다. 본 논문에서는 소음원과 소음전파의 주파수 특성을 고려하여 철도 소음의 예측 정확도를 향상할 수 있는 예측 모델을 제안하였다. 먼저 철도 소음원을 궤도(레일 및 침목), 차륜, 동력, 공력 성분으로 구분하여 각각의 옥타브 밴드 주파수별 음향파워와 속도계수를 정의하고 음향 조도와 궤도/교량 특성을 반영할 수 있는 보정항을 도입하였다. 소음원에서 수음점까지의 전파 특성은 ISO 9613-2를 적용하여 기하학적 확산, 대기 흡음, 지면 효과, 장애물의 회절에 따른 감쇠 및 지향특성을 반영하여 계산하였다. 소음원 음향파워와 지향인자를 추정하기 위하여 전동 소음원 해석 모델 및 수치해석 결과와 통과 소음도 측정값을 이용하였다. 본 철도 소음 예측 모델을 이용하여 여러 철도 차량과 궤도 유형에 따라서 예측한 소음도를 측정값과 비교하여 정확도를 검증하였으며 기존 예측 모델보다 비교적 정확한 예측이 가능하였다. 따라서 본 결과는 철도 환경 소음의 정확한 영향 예측과 효율적인 소음 저감 대책 수립에 활용될 수 있을 것이다.

촉진 양생한 무기계 MiDF 콘크리트에서 실리카질 원료의 반응성에 관한 기초 연구 (Fundamental Research on Reactivity of Silica Source in the Rapidly Cured Inorganic Micro-Defect-Free(MiDF) Concrete)

  • 최홍범;김진만
    • 한국건설순환자원학회논문집
    • /
    • 제7권2호
    • /
    • pp.166-173
    • /
    • 2019
  • 본 연구에서는 오토클레이브를 활용한 촉진양생 조건에서 실리카 원료의 반응 특성 및 이를 활용한 무기계 MiDF 콘크리트의 기초 특성을 검토하였다. 다양한 나노 물질의 반응성을 알아보기 위한 용출 특성 실험에서 오토클레이브 양생 시 Si 이온의 용출은 비결정질의 원료에서 더 높게 나타났다. 상수 분위기에서 오토클레이브 양생된 고형물은 비결정질 원료일수록 높은 질량 감소를 보였는데, 이는 이온의 용출량이 높기 때문으로 사료된다. $Ca(OH)_2$ 수용액 조건에서는 비결정질 원료가 많은 질량 증가를 보였는데, 이는 C-S-H의 생성에 기인한 것이다. 나노 실리카 재료가 MiDF의 특성에 미치는 실험에서 실리카 퓸은 대체율 5.5%까지 MiDF의 압축강도 증가와 흡수율 감소에 기여하였고, 비결정질의 고분말도 나노 실리카는 대체율이 증가함에 따라 압축강도는 저하하였지만 흡수율 감소에 기여하였다. 또한 나노 실리카를 첨가한 시험체는 기대와 달리 10,000nm 이하의 공극은 증가하였지만, 10,000~100,000nm 범위의 공극은 감소하는 것으로 나타났다. 이상의 결과를 통해 비정질의 나노 사이즈 실리카를 활용하여 MiDF 콘크리트의 공극 및 흡수율을 저감이 가능함을 알 수 있었다. 그러나 목표로 하였던 50~10,000nm 사이의 공극을 줄이기 위해서는 시멘트 매트릭스에 나노 재료를 더욱 잘 분산시키는 것이 필요할 것이며, 이에 관한 연구가 지속될 필요가 있다.

Acoustic Emission 의 섬유파단 Source Location을 이용한 Carbon Fiber/Epoxy Composites의 계면특성 및 비파괴적 평가 (Interfacial and Nondestructive Evaluation of Single Carbon Fiber/Epoxy Composites by Fiber Fracture Source Location using Acoustic Emission)

  • Kong, Jin-Woo;Kim, Jin-Won;Park, Joung-Man;Yoon, Dong-Jin
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.116-120
    • /
    • 2001
  • Fiber fracture is one of the dominant failure phenomena to determine total mechanical properties in composites. Fiber fracture locations were measured by optical microscopic method and acoustic emission (AE) as functions of matrix toughness and surface treatment by the electrodeposition (ED), and then two methods were compared. Two AE sensors were attached on the epoxy specimen and fiber fracture signals were detected with elapsed time. The interfacial shear stress (IFSS) was measured using tensile fragmentation test and AE system. In ED-treated case, the number of the fiber fracture measured by an optical method and AE was more than that of the untreated case. The signal number measured by AE were rather smaller than the number of fragments measured by optical method, since some fiber fracture signals were lost while AE detection. However, one-to-one correspondence between the x-position location by AE and real break positions by optical method was generally established well. The fiber break source location using AE can be a valuable method to measure IFSS for semi- or nontransparent matrix composites nondestructively (NDT).

  • PDF