• 제목/요약/키워드: source location technique

검색결과 130건 처리시간 0.028초

굽힘 압전 복합재료 작동기의 전기적 피로 거동 (Electric Fatigue Behavior of a Bending Piezoelectric Composite Actuator)

  • 우성충;구남서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.362-367
    • /
    • 2008
  • In the present work, we address electric fatigue behavior in bending piezoelectric actuators using an acoustic emission technique. Electric cyclic fatigue tests have been performed up to ten million cycles on the fabricated specimens. To confirm the fatigue damage onset and its pathway, the source location and distributions of the AE behavior in terms of count rate are analyzed over the fatigue range. It is concluded that electric cyclic loading leads to fatigue damages such as transgranular damages and intergranular cracking in the surface of the PZT ceramic layer, and intergranular cracking even develops into the PZT inner layer, thereby degrading the displacement performance. The electric-induced fatigue behavior seems to show not a continuous process but a step-by-step process because of the brittleness of PZT ceramic. Nevertheless, this fatigue damage and cracking do not cause the final failure of the bending piezoelectric actuator loaded up to 107 cycles. Investigations of the AE behavior and the linear AE source location reveal that the onset time of the fatigue damage varies considerably depending on the existence of a glass-epoxy protecting layer.

  • PDF

전기적 피로하중을 받는 압전 작동기의 손상 메커니즘 (Damage Mechanisms of a Piezoelectric Actuator under Electric Fatigue Loading)

  • 우성충;구남서
    • 대한기계학회논문집A
    • /
    • 제32권10호
    • /
    • pp.856-865
    • /
    • 2008
  • Damage mechanisms in bending piezoelectric actuators under electric fatigue loading are addressed in this work with the aid of an acoustic emission (AE) technique. Electric cyclic fatigue tests have been performed up to $10^7$ cycles on the fabricated bending piezoelectric actuators. An applied electric loading range is from -6 kV/cm to +6 kV/cm, which is below the coercive field strength of the PZT ceramic. To confirm the fatigue damage onset and its pathway, the source location and distributions of the AE behavior in terms of count rate and amplitude are analyzed over the fatigue range. It is concluded that electric cyclic loading leads to fatigue damages such as transgranular damages and intergranular cracking in the surface of the PZT ceramic layer, and intergranular cracking even develops into the PZ inner layer, thereby degrading the displacement performance. However, this fatigue damage and cracking do not cause the final failure of the bending piezoelectric actuator loaded up to $10^7$ cycles. Investigations of the AE behavior and the linear AE source location reveal that the onset time of the fatigue damage varies considerably depending on the existence of a glass-epoxy protecting layer.

센서 네트워크에서 RSSI 값과 위치 추정 기반의 에너지 효율적인 라우팅 프로토콜 (Energy-efficient routing protocol based on Localization Identification and RSSI value in sensor network)

  • 김용태;정윤수;박길철
    • 디지털융복합연구
    • /
    • 제12권1호
    • /
    • pp.339-345
    • /
    • 2014
  • 본 연구는 기존에 연구된 다양한 라우팅 기법들보다 노드의 이동에 따른 적응력 향상과 에너지 관리의 효율성을 향상하는데 목적이 있다. 본 연구의 목적은 각각의 센서 노드들에 의해 수신되는 RSSI 값과 센서의 위치 정보를 라우팅에 활용하는 기법이다. 본 연구는 주변 1-홉(hop) 거리의 노드 정보를 저장하지 않는다. 그리고 근거리 다중홉 전송 기법에서 중계 노드 선택을 위한 정보 교환 과정에서 발생하는 에너지 비효율적인 트래픽 문제를 해결한다. 본 연구에서 제안하는 라우팅 프로토콜 기법은 각각의 노드들이 수신하는 RSSI 값이 설정된 전송 범위에 해당하는 노드를 선택하고 그리고 선택된 노드의 위치 정보를 바탕으로 목적지 노드에 가장 가까운 노드를 중계 노드로 선정하는 기법이다. 따라서 목적지 노드까지 데이터 전달 홉 수를 줄이고, 에너지를 효율적으로 관리하여 노드의 에너지 고갈을 방지하기 위한 것이다.

MANET 환경에서 DDoS 공격 완화 기법에 관한 연구 (A Study on DDoS Attack Mitigation Technique in MANET)

  • 양환석;유승재
    • 융합보안논문지
    • /
    • 제12권1호
    • /
    • pp.3-8
    • /
    • 2012
  • 고정된 인프라스트럭쳐 없이 무선 노드로만 구성된 MANET은 높은 유연성을 제공하지만, 다양한 공격에 취약한 단점을 가지고 있다. 특히 모든 노드들이 패킷 포워딩을 수행해야 하기 때문에 DDoS 공격에 큰 취약점을 가지고 있다. 본 논문에서는 MANET에서 DDoS 공격의 피해를 완화시키고, DDoS 공격 발생시 공격자의 위치를 찾기 위한 패킷 전송 정보 관리 기법을 제안하였다. 본 논문에서는 DDoS 공격 대상을 보호하기 위하여 게이트웨이 노드를 이용하는 계층구조를 채택하였다. 소스 노드가 목적지 노드까지 경로 설정시 목적지 노드와 같은 클러스터내의 게이트웨이 노드가 반드시 포함되어야 하며, 이 게이트웨이 노드는 목적지 노드를 보호하는 기능을 수행한다. 본 논문에서 제안한 기법은 CUSUM 기법과 비교 실험하여 효율성을 확인하였고, 위치 추적에 사용할 정보 관리의 효율성을 평가하기 위해 클러스터 헤드의 메모리 사용량을 측정하였다.

Impact Localization for a Composite Plate Using the Spatial Focusing Properties of Advanced Signal Processing Techniques

  • Jeong, Hyunjo;Cho, Sungjong
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.703-710
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a composite plate is presented in this paper. The method employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the spatial focusing efficiency of both approaches at the impact position and its surroundings through impact experiments. The imaging results of impact localization show that the impact location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring knowledge of anisotropic material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testing of plate-like structures.

모르터와 콘크리트의 균열검출을 위한 음향방출기법의 적용 (Application of Acoustic Emission Technique for Detection of Crack in Mortar and Concrete)

  • 진치섭;신동익;장종철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.739-744
    • /
    • 2000
  • Concrete structures generally have cracks, so for the safety and durability of structures, studies to detect cracks using nondestructive tests have been treated in great deal. In order to assure the reliability of concrete structure, microscopic fracture behavior and internal damage progress of concrete under the loading should be fully understood. The purpose of this study predicts location of initial crack and measures direction of crack propagation for on-line monitoring before the crack really grows in structures by using two-dimensional Acoustic Emission(AE) source location based on rectangular method with three-point bending test. This will allow efficient maintenance of concrete structure through monitoring of internal cracking based on AE method.

  • PDF

Shearography 기법에 의한 압력 배관 내부 결함 검출에서 전단량의 영향 (Influence of Shearing Amount on Detection of Internal Defect of Pressure Pipeline by Shearography)

  • 김경석;강기수;최만용;강영준
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.122-129
    • /
    • 2006
  • 본 논문에서는 레이저 응용 비파괴검사 기술인 Shearography를 이용하여 압력 배관 내부 결함의 검출에 있어서 미치는 전단량의 영향을 분석하였다. Shearography는 레이저 응용기법에 비하여 환경 외란에 둔감하며, 대상체 표면의 상대 변위를 검출함으로서 비파괴검사 분야에서 많은 활용이 기대된다. 현재까지 연구는 적용 가능성의 평가와 적용 대상의 확대에 중점을 두어 연구가 진행되어 왔으며, 결함의 정량평가를 위해서는 결함 검출에 있어서 영향을 주는 인자들에 대한 연구가 필요하다. 따라서 본 논문에서는 결함의 검출에 영향을 줄 수 있는 전단량의 변화에 따라 결함의 크기 측정과 길함의 위치 결정에 대한 영향을 예측하고, 압력용기 내부의 길이 방향 인공 결함에 대해 적용하여 검출 결과를 분석하였다.

Development of New Methods for Position Estimation of Underground Acoustic Source Using a Passive SONAR System

  • Jarng, Soon-Suck;Lee, Je-Hyeong;Ahn, Heung-Gu
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권1호
    • /
    • pp.69-75
    • /
    • 2000
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about 100m underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

수동형 SONAR 시스템을 사용한 지하 진원지의 추정 (Position estimation of underground acoustic source origin using a passive SONAR system)

  • 장순석;이제형;안흥구;최현호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.103-108
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about loom underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

New Acoustic Imaging Method Development for Localization of an Underground Acoustic Source Using a Passive SONAR System

  • Jarng, Soon-Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권2E호
    • /
    • pp.10-17
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about 100m underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF