• Title/Summary/Keyword: source environment

Search Result 4,203, Processing Time 0.031 seconds

Construction of Open-source Program Platform for Efficient Numerical Analysis and Its Case Study (효율적 수치해석을 위한 오픈소스 프로그램 기반 해석 플랫폼 구축 및 사례 연구)

  • Park, Chan-Hee;Kim, Taehyun;Park, Eui-Seob;Jung, Yong-Bok;Bang, Eun-Seok
    • Tunnel and Underground Space
    • /
    • v.30 no.6
    • /
    • pp.509-518
    • /
    • 2020
  • This study constructed a new simulation platform, including mesh generation process, numerical simulation, and post-processing for results analysis based on exploration data to perform real-scale numerical analysis considering the actual geological structure efficiently. To build the simulation platform, we applied for open-source programs. The source code is open to be available for code modification according to the researcher's needs and compatibility with various numerical simulation programs. First, a three-dimensional model(3D) is acquired based on the exploration data obtained using a drone. Then, the domain's mesh density was adjusted to an interpretable level using Blender, the free and open-source 3D creation suite. The next step is to create a 3D numerical model by creating a tetrahedral volume mesh inside the domain using Gmsh, a finite element mesh generation program. To use the mesh information obtained through Gmsh in a numerical simulation program, a converting process to conform to the program's mesh creation protocol is required. We applied a Python code for the procedure. After we completed the stability analysis, we have created various visualization of the study using ParaView, another open-source visualization and data analysis program. We successfully performed a preliminary stability analysis on the full-scale Dokdo model based on drone-acquired data to confirm the usefulness of the proposed platform. The proposed simulation platform in this study can be of various analysis processes in future research.

Development and Learning Outcome Analysis of an Efficient e-Learning Environment using Open Source LMS (오픈소스 LMS를 이용한 효율적 e-Learning 환경 구축과 학습결과 분석에 관한 연구)

  • Heo, Won;Yang, Yong-Seok;Park, Gi-Won;Bu, Ti-Tu
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.559-570
    • /
    • 2005
  • This paper presents how to establish an efficient e-Learning environment using open source software. A LMS with additional functionalities on the top of dotLRN. which is a open source project for LMS, is presented. Additional functionalities include modification of the language for Korean, adoption of SCORM educational standard, and management of learning outcome. This system had been serviced for Kongju cyber university for one year on stable basis. The scope of this paper covers introduction, characteristics review, and the learner's learning outcome analysis.

  • PDF

Evaluation of Fugitive Emission Characteristics of Airborne Volatile Organic Compounds from Different Source Categories (발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출 특성 평가)

  • 백성옥;김미현;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.363-376
    • /
    • 2003
  • In this study, the fugitive emission characteristics of airborne volatile organic compounds from different source categories were evaluated with respect to the concentrations measured in the vicinity of the sources. A total of 22 different sources were investigated, including gasoline storage and filling stations, painting spray booth, laundry, printing officer, textile industries, and a number of environmental sanitary facilities such as landfill, wastewater treatment and incineration plants. The target VOCs included 83 individual compounds, which were determined by adsorption sampling and thermal desorption coupled with GC/MS analysis. Overall, the aliphatic compounds appeared to be the most abundant class of compounds in terms of their concentrations, followed by aromatic, and halogenated hydrocarbons. As a single compound, however, toluene was the most abundant one, explaining 11% of the total VOC concentrations as an average of all the dataset. Among source categories, petroleum associated sources such as gasoline storage/filling stations, and laundry factory were identified as the most significant sources of aliphatic hydrocarbons, while aromatic VOCs were dominantly emitted from the sources handling organic solvents, such as painting booth, printing offices, and textile dyeing processes. However. there was no apparent pattern in terms of the contributions of eath group to the total VOCs concentrations in environmental sanitary facilities. It was also found that the activated carbon adsorption tower installed for the VOC emission control in some facilities do not show any effective performances, which may result in the increased VOC levels in the ambient atmosphere.

Regional Distribution Characteristics of Total Gaseous Mercury in Air-Measurements from Urban and Mountainous Sites in Korea (대기 중 수은의 지역적 분포특성에 대한 비교연구-한반도의 도심과 산악지역을 중심으로)

  • 김민영;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • The spatial distribution characteristics of airborbe mercury(Hg) were investigated used its concentration data from six measurement sites selected to represent:(1) three terminal sites with heavy traffic loads in urban area, (2) one urban residential site and (3) two mountainous sites in Korea. The measurement data obtained during September 1997 through May 1998 indicated that the mean concentration of Hg from different study sites were comparably high with the mean values spanning from 5-9ng./㎥. The concentration from all those sites were systmatically high compared to those of most background sites around world or to other Korean sites investigaed previously. When results of correlation analysis between Hg and relevant parameters were compared among different study sites. temperature was most frequently found out to be in strong correlation with Hg concentrations. Results of factor analysis also indicated that Hg concentrations could be affected simultaneously by th factors affecting such parameters as ozone, temperature, ozone, carbon monoxide, and PM. The findings of enhanced Hg levels from Ji-Ri Mountain relative to terminal site suggest that is distributions may be rather homogeneous not enough to clearly distinguish areal differences and the associated source signatures between urban and rural area. The existence of systmatically high concentrations from all investigated sites also indicate that the impact of its source processes should be quite ubiquitous, while highly variable in relatively long term scale.

  • PDF

Effect of Contaminant Source Location on Indoor Air Quality

  • Lee, Hee-Kwan;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.1-7
    • /
    • 1998
  • This paper presents an experimental study for understanding the indoor air quality in a room. A model room, which had a ceiling-mounted supply and a sidewall-mounted exhaust, was used to examine the effect of air exchange rate (AER) and contaminant source location (CSL) as a function of the elapsed time. A tracer gas method, using carbon monoxide tracer, gas analyzers, and a data acquisition system, was applied to study the ventilation air distribution and the tracer removal efficiency, so-called pollutant removal efficiency, in the model room. The experiment was composed of two parts; firstly the AER was varied to examine its effect on the ventilation air distribution and the ventilation effectiveness and secondly both AER and CSL were considered to determine their effect on the pollutant removal efficiency. It was found that the ventilation effectiveness in the model was proportional to AER but not linearly. It was also found that changing the CSL can improve the pollutant removal efficiency. In some cases, the efficiency improvement by increasing AER was achieved by simply changing CSL.

  • PDF

A Study on the Discharge Characteristics of Non-point Pollutant Source in the Agricultural Area of the Kyongan Watershed (경안천 유역 농촌지역의 비점오염원 배출 특성에 관한 연구)

  • Lee, Byung-Soo;Jung, Yong-jun;Park, Moo Jong;Gil, Kyung-Ik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.169-173
    • /
    • 2008
  • A field monitoring was conducted in order to find out the discharge characteristics of non-point source pollutants in the agricultural area. Event Mean Concentration (EMC) of TSS, $BOD_5$, $COD_{Mn}$, TP, TN was calculated based on the monitoring data of 10 rainfall events at agricultural watersheds. A significant relationship was observed from the correlation between EMCs and rainfall characteristics. The result shows that EMC ranges of 95% confidence intervals were 50.5~203 mg/L for TSS, 0.8~14.2 mg/L for $BOD_5$, 4.2~20.7 mg/L for $COD_{Mn}$, 2.4~4.5 mg/L for TN and 0.2~0.5 mg/L for TP, respectively. The correlation coefficients between TSS and TP and between $BOD_5$ and $COD_{Mn}$ were found to be 0.912 and 0.961. But TN was lower correlated with other EMC factors. It was also found that rainfall characteristics was not correlated with EMCs.

Pollutant Source Database and Water Quality Managemen Ecosystem Model for Juam Reservoir Watershed Using GIS (GIS를 응용한 주암 상수원수계의 오염원 DB 구축과 수질관리 생태계모형)

  • 양홍모;권유리
    • Korean Journal of Environment and Ecology
    • /
    • v.13 no.3
    • /
    • pp.209-219
    • /
    • 1999
  • 주암호는 전라남도와 광주광역시에 약 1,180,000톤/일의 생활용수와 공업용수를 공급하는 상수원이다. 상수원수계의 생활하수, 축산폐수, 숙박업소, 식당 등 점오염원과 주거지, 농경지, 산림지역에서 우수와 함께 유출되는 비점오염원으로부터 발생하는 오염부하량으로 이들 상수원의 수질은 점점 악화되어 3급수로 전락할 우려가 높아지고 있다. 이들 상수원의 수질관리에 있어 중요한 인자의 파악과 인자들간 상호작용의 이해를 용이하게 해주는 수계수질관리 부분생태계모형을 제시하였으며 지리정보체계를 응용하여 수계의 점오염원과 비점오염원을 데이터베이스화하는 방법, 오염부하량 산출방법, 점원 및 비점오염원의 공간분석, 상수원 보호구역으로부터 완충구역분석, 위성자료 분석을통한 상수원 수계 토지이용분석과 비점오염원 부하량산출 응용 방법등을 연구하였다 분석결과 주암호수계의 BOD 부하량은 주거지. 생활하수, 축산폐수, 경작지, 식당이 차지하는 비율이 높으며 총질소 부하량은 경작지, 산림, 생활하수, 추간폐수가 높으며 그리고 총인 부하량은 생활하수, 축산폐수, 경작지가 높은 것으로 나타났다. 점오염원인 생활하수, 축산폐수, 식당 뿐만 아니라 비점오염원인 경작지도 수질오염에 상당한 영향을 미치고 있다.

  • PDF

A study on the utilization of exhausted heat from subway for energy source of heat pump (공기열원 히트펌프의 에너지원으로서 지하철 배열 이용에 관한 연구)

  • Kim J.R.;Jeong K.C.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.13-19
    • /
    • 2000
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was performed as follows The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying.

  • PDF

Classification of Individual Ambient Particles by CCSEM (CCSEM을 이용한 대기 중 개별분진의 분류에 관한 연구)

  • 장여진;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.5
    • /
    • pp.345-353
    • /
    • 1997
  • The purpose of the study was to stastically classify individual PM-10 measured by SEM/EDX (scanning electron microscopy/energy dispersive x-ray analyzer). The SEM/EDX provided various physical parameters like optical diameter, as well as major 18 chemical information (Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb) for a particle-by-particle basis. The total of 1,419 particles were analyzed for the study. Thus density and mass of each particle can be estimated based on its chemical composition. Further the study developed 4 semisource profiles including highway, oil boiler, incinerator, and soil emissions, where each sample was collected near the source in the ambient air The profiles developed were consisted of mass fractions and their uncertainties based on a particle class concept. To obtain mass fraction of each particle class, an agglomerative hierarchical cluster analysis was initially applied to create particle classes for each sample. Then uncertainties were calculated for each class based on the jacknife method. The 1,258 particles out of 1,419 (88.7%) were assorted in newly generated particle classes. The study provides opportunities to identify particle's source quantitatively and to develope various receptor models.

  • PDF

Characteristics of Heavy Metal Emissions from Stationary Sources (고정오염원에서의 중금속 배출특성 연구)

  • Park, Jung-Min;Lee, Sang-Bo;Cha, Jun-Seok;Kwon, Oh-Sang;Lee, Sang-Hak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.574-583
    • /
    • 2008
  • The results of HAPs emission data using TRI (Toxic Release Inventory), SODAM (Source Data Management system) were investigated and the emissions of 7 heavy metals from their sources and emission processes were also analyzed. Questionnaire for source data analysis as well as the stack sampling were carried out for 17 factories among 6 selected industrial types. The annual amount of emissions was estimated based on the measured concentration and flow rates. All sources were operated with high efficiency control devices and the concentration levels of all heavy metals were shown to be below 0.1 to of regulation standard. The highest emission source of heavy metals was steel manufacturing industry with the annual emission of 342.9 kg/yr and followed by hazardous waste incinerator, paint manufacturing, nonferrous metal manufacturing, rolling & press goods manufacturing and storage battery manufacturing. In the case of Hg, the emissions were quite significant from electric acros of steel manufacturing industry, although the concentration level was below the emission standard, showing the necessity of specific care for its management.