• Title/Summary/Keyword: source environment

Search Result 4,203, Processing Time 0.031 seconds

Source Identification of PM-10 in Suwon Using the Method of Positive Matrix Factorization (PMF 방법론을 이용한 수원지역 PM-10의 오염원 확인)

  • 황인조;김태오;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.133-145
    • /
    • 2001
  • The receptor modeling is one of the statistical methods to achieve reasonable air pollution strategies. The pur-pose of this study was to survey the concentration variability oi inorganic elements and ionic species in the PM-10 particles, to qualitatively characterize emission sources by an advanced algorithm called positive matrix factoriza-tion(PMF) as a receptor model that can strictly provide results in every loading matrix. A total of 254 samples was collected by a PM-10 high volume air sampler from Mar. 1997 to Feb. 1998 in Kyung Hee University at Suwon Campus. Fourteen chemical species(Zn, Cu, Fe, Pb, Al, Mn, $Na^{+}$, NH$_4$+, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$, $SO_4^{2-}$, $NO_{3}^{-}$, and $Cl^{-}$) were determined by AAS and IC methods. The study results showed that the average monthly concentration of PM-10 particles were 86.3$\mu\textrm{g}$/$\textrm{m}^3$ in March (maximum) and 28.5$\mu\textrm{g}$/$\textrm{m}^3$ in August(minimum), respectively. The concentrations of Na+, NH$_4$+, $K^{+}$ and $Cl^{-}$ in winter, $Mg^{2+}$, $Ca^{2+}$ and $NO_{3}^{-}$, in spring, and $SO_4^{2-}$ in summer showed the largest peak concentration for the respective season. Through and app-lication of a PMF program of Pm-10 concentration data of Suwon, 9 sources were qualitatively identified , such as incineration source, oil burning source, soil related source, open burning source automobile source, coal burning sources, secondary sulfate related source, and secondary nitrate related source.

  • PDF

Study of the propagation problem in the curved source of vibration (곡선진동원에서의 진동전파문제 연구)

  • Oh, Jang-Haun;Huh, Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1112-1115
    • /
    • 2004
  • Recently, KTX start service 2004 and speed up the Chung-ang line and Ho-nam line using tilting train. When the train speed up at curve the vibration environment are changed. It is the reason of the wave propagation problem in the curved source. In this research, using SSI Program SASSI, Predict the vibration propagation around the curved source of vibration. The curved source of vibration propagation is different from straight source of vibration propagation. In this study, made a curved vibration source model and compared with straight model.

  • PDF

Development Environment for Open-pit Mine Monitoring System using Geospatial Open Platform and Open Source Software (공간정보오픈플랫폼 및 오픈 소스 기반의 노천광산 모니터링시스템 개발을 위한 환경 조성)

  • Lee, Hyun Jik;Kim, Se Yul;You, Ji Ho
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.165-173
    • /
    • 2014
  • Open-pit mining method, is safe relatively work as compared with underground mining. And high yield, low production cost, has the advantage that it can provide a lot of production. But deforestation, tailings and slag deposition, mineral debris, dust, water, noise, land subsidence, sediment runoff discharge, I have internalized environmental disaster predisposing factors, such as landslides. Thus, it may be noted, also by typical environmental regulations. We try to deal with the changes in open pit terrain and environment related issues. Then, use the recovery period and the open pit mine and ecology off the gun, environment-friendly development of accurate monitoring methods, systems of this development is required. The use of open platforms and open source GIS tools have been developed during this period, it needs to develop spatial information environment monitoring system open pit mine construction.

A scheme of Docker-based Version Control for Open Source Project (오픈 소스 프로젝트를 위한 도커 기반 버전 관리 기법)

  • Lee, Yong-Jeon;Rim, Seong-Rak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.8-14
    • /
    • 2016
  • When Open Source Projects are processed by multiple developers, the Version Control Systems, which control the different versions of the same file being used, is a very useful tool. On the other hand, because most of conventional VCS(SVN, Git, etc.) mainly control the history of the modifications of the source codes or documents, there is an inconvenience that each developer should modify the development environment whenever the development environment is modified. To overcome this inconvenience, this paper suggests a scheme of VC for OSP. The basic concept of the suggested scheme is that an image, including the development environment and controls, is created as a new version using the Docker, virtualization tool of the container method. To review the functional appropriateness of the suggested scheme, after establishing the Docker on the hosts that use the different OS( Ubuntu12.0.4, CentOS7), this study tested a VC that could control the different versions including the history of modifications of the development environment and evaluated them by a comparison with the conventional VCS. The results show that the suggested scheme is a convenient scheme of VC for the OSP.

Watershed Selection for Diffuse Pollution Management Based on Flow Regime Alteration and Water Quality Variation Analysis (유황분석과 수질변화 평가를 통한 비점오염원 관리대상지역 선정방법 연구)

  • Jung, Woohyeuk;Yi, Sangjin;Kim, Geonha;Jeong, Sangman
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.228-234
    • /
    • 2011
  • The goal of water quality management on stream and watershed is to focus not on discharged loads management but on a water quality management. Discharged loads management is not goal of water quality management but way for perform with total maximum daily loads management. It is necessary to estimate the relation between non-point source with stromwater runoff (NPSSR) and water quality to select a watershed where it is required to manage NPSSR for water quality improvement. To evaluate the effects of NPSSR on stream's water quality, we compare the aspects of water quality in dry and wet seasons using flow duration curve analysis based on flow rate variation data by actual surveying. In this study we attempt to quantify the variation characteristic of water quality and estimate the Inflow characteristic of pollution source with water quality and flow rate monitoring on 10 watersheds. We try to estimate water quality and flow rate by regression analysis and try again regression analysis with each high and low water quality data more than estimations. An analysis of relation between water quality and flow rate of 10 watersheds shows that the water quality of the Nonsan and the Ganggyeong streams had been polluted by NPSSR pollutants. Other eight streams were important point source more than NPSSR. It is wide variation range of $BOD_5$ also high average concentration of $BOD_5$. We have to quantify water quality variation by cv1 in wet season and cv365 in dry season with comparing the estimate of high water quality and low water quality. This method can be used to indicator for water quality variation according to flow rate.

Development of e-Learning System Based on Open Source Software (공개 소프트웨어 기반 e-Learning 시스템 개발)

  • Lee Se-Hoon;Baek Yeong-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • In this paper we developed e-Leaning system based on open source software. We selected the Moodle that after compared the open source learning management systems. Moodle is LAMP(Linux, Apache, MySQL, PHP) based course management system (CMS), a software package designed to help educators create quality online courses. One of the main advantages of Moodle over other systems is a strong grounding in social constructionist pedagogy. Also we integrated Moodle and legacy systems such as streaming service, webhard service, and short message service. The system operated during one semester at college using blended learning model. We had obtained showed that the students had almost all scored quite highly as preferred learning environment through COLLES(Constructivist On-Line Learning Environment Survey) and ATTLS(Attitudes to Thinking and Learning Survey). Therefore this research showed that open source based e-Loaming system is stable and possible.

  • PDF

Density Distributions of Metallic Compounds in Particulate Matters (粒子狀 物質中 金屬成分의 密度分布)

  • 허문영;김형춘;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.9-18
    • /
    • 1986
  • For identification and apportionment of sources emitting particulate matters in environment, the multi-elemental characterization of size-density fractionated particulate matters was carried out. Eight types of samples were tested; soil, flyash released from burning of bunker-Coil, diesel oil, coal, and soft coal, urban road-way dust, urban dust fall, and airborne particulate matter. The fractions of particulate matters obtained by heavy liquid separation methos with a series of dichloromethane-bromoform were then analyzed using atomic absorption spectrophotometry for Ni, Cr, Cu, An, Fe, Al, and Mg. Each sample showed a different concentration profile as a function of density, and a number of useful conclusions concerning characterization of elemental distribution were obtained. From the density distributions of elements in soil, the maximum value was found for all elements in the density range of 2.2 $\sim 2.9g.cm^{-3}$, including the density of $SiO_2$. However, the distribution of metallic compounds with the density lower than $2.2g.cm^{-3}$ was prevalent in urban roadway dust, urban dust fall, and airborne particulate matter. And the density distribution curves of these urban dusts also have the higher distribution at the density of 2.2 - 2.9g.cm^{-3}$, including the density of wind-blown silica. This tendency generally was prevalent in the natural source elements, such as Al, Fe, Mn, and Mg. The maximum values were found in the density ranges of 1.3 $\sim 2.2g.cm^{-3}$ from the density distribution of elements in oil fired flyash. These distributions of anthropogenic source elements, such as Zn, Ni, Cu, and Cr were higher predominately than those of natural source elements. And the higher distribution was found in the density range of $2.2 \sim 2.9g.cm^{-3}$ from the density distribution of elements in coal and soft-coal fired flyash. These distributions showed similar patterns to soil. But anthropogenic source elements somewhat predominated at the density ranges of $1.3 \sim 2.2g.cm{-3} and 2.9g.cm^{-3}$ to soil. Therefore the higher distribution of anthropogenic source elements in the density ranges of $1.3 \sim 2.2g.cm^{-3} and 2.9g.cm^{-3}$ was considered as anthropogenic origin.

  • PDF

Identification of Atmospheric PM10 Sources and Estimating Their Contributions to the Yongin-Suwon Bordering Area by Using PMF (PMF모델을 이용한 용인.수원 경계지역에서 PM10 오염원의 확인과 상대적 기여도의 추정)

  • Lee, Hyung-Woo;Lee, Tae-Jung;Yang, Sung-Su;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.439-454
    • /
    • 2008
  • The purpose of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions to the study area, based on the analysis of the $PM_{10}$ mass concentration and the associated inorganic elements, ions, and total carbon. The contribution of $PM_{10}$ sources was estimated by applying a receptor method because identifying air emission sources were effective way to control the ambient air quality. $PM_{10}$ particles were collected from May to November 2007 in the Yongin-Suwon bordering area. $PM_{10}$ samples were collected on quartz filters by a $PM_{10}$ high-volume air sampler. The inorganic elements (Al, Mn, V, Cr, Fe, Ni, Cu, Zn, Cd, Pb, Si, Ba, Ti and Ag) were analyzed by an ICP-AES after proper pre-treatments of each sample. The ionic components of these $PM_{10}$ samples ($Cl^_$, $NO_3^-$, $SO_4^{2-}$, $Na^+$, $NH_4^+$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$) were analyzed by an IC. The carbon components (OC1, OC2, OC3, OC4, OP, EC1, EC2 and EC3) were also analyzed by DRI/OGC analyzer. Source apportionment of $PM_{10}$ was performed using a positive matrix factorization (PMF) model. After performing PMF modeling, a total of 8 sources were identified and their contribution were estimated. Contributions from each emission source were as follows: 13.8% from oil combustion and industrial related source, 25.4% from soil source, 22.1% from secondary sulfate, 12.3% from secondary nitrate, 17.7% from auto emission including diesel (12.1%) and gasoline (5.6%), 3.1% from waste incineration and 5.6% from Na-rich source. This study provides information on the major sources affecting air quality in the receptor site, and therefore it will help us maintain and manage the ambient air quality in the Yongin-Suwon bordering area by establishing reliable control strategies for the related sources.

Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building (대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Lee, Jong-Gil;Hong, Seong-Ho;Choi, Young-Don;Cho, Sung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF