• Title/Summary/Keyword: sound vibration

Search Result 2,252, Processing Time 0.034 seconds

Study on Shear Layer Correction of Microphone Array Measurement in the Wind Tunnel Test (풍동 조건의 마이크로폰 어레이 측정에서 전단층 보정에 관한 연구)

  • Kim, Wi-Jun;Rhee, Wook;Choi, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.92-96
    • /
    • 2007
  • Microphone array beamforming method has been recognized as an important aeroacoustic research field and become a standard technique in localizing sound sources. This method also used in flight acoustic measurement, and especially, it is very useful when measure sounds inside the wind tunnel. In measuring sound which is inside the wind tunnel by traditional beamforming method, there are some errors caused by airstream. The speed and the propagation path of the sound changes as it travel through the airstream. This makes the error which the position of sound is changed a little bit to the down stream direction. In this paper, validation test has made about the correction equation for this wind effects of previous researches. And beamforming including shear layer correction was performed about a sound source in the anechoic open-jet windtunnel.

  • PDF

A study on the sound insulation performance of damping sheet attached to the train wall (철도차량벽체의 차음 성능에 대한 제진시트의 영향 고찰)

  • Seo, Dae-Hoon;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.97-100
    • /
    • 2007
  • This study deals with the sound insulation performance of the damping sheet, which is widely used in a train. The wall of train is assumed to be a plate made of steel and two damping sheets. In case of damping sheet only, the sound transmission loss follows the mass law. If a steel plate is attached to damping sheet, the transmission loss is found to be higher than single of only steel plate, as we can anticipated, about $3{\sim}5$ dB. This is very well known consequence that is because the density of area increases. However, the increase of the transmission loss is not higher than what we can expect by the mass law. That's because the steel is perfectly blocked from the transmission of the air ; There is no defect in that material.

  • PDF

Characteristics of Sound Reduction Index through Small Sized Lightweight Panel (소형 경량판넬을 이용한 차음성능 영향요인별 음향감쇠계수 분석)

  • Yang, Hong-Seok;Kim, Myung-Jun;Jeong, Gab-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.138-147
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

  • PDF

Evaluation of sound insulation performance according to aperture conditions under the flush door (세대내 플러시 도어의 하부틈새 조건에 따른 차음성능 평가)

  • An, Ji-Hyeong;Kim, Myung-Jun;Lee, Min-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.153-158
    • /
    • 2007
  • Sound insulation performance of the flush door in the apartment unit was recently decreased due to the door for the purpose of barrier free. To evaluate sound insulation, the test for 13 kinds of flush doors was performed as aperture conditions under the flush door. and the measured value was compared with the predicted values of theoretical sound transmission. The results were summarized follow; First, in case of doors with aperture by barrier free, the single number quantities ($D_{pw}$) were evaluated $21{\sim}23dB$. Whereas, in case of existing door with frame, $D_{pw}$ was evaluated $28{\sim}31dB$. And in case of sealed doors, $D_{pw}$ was evaluated $31{\sim}34dB$. Second, the measured $D_{pw}$ was good agreement with the predicted $D_{pw}$ in condition of small aperture.

  • PDF

Auditory Perception Experiment on Attribute of Road Traffic Noise Causing Annoyance with Identical Linear Sound Pressure Level (동일한 선형 음압 레벨의 도로교통소음의 성가심 유발 인자에 관한 연구)

  • An, Jang-Ho;Schang, Seo-Il;Ko, J.H.;Chun, Hyung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.641-648
    • /
    • 2006
  • This study investigates which sound quality indices except SPL raise annoyance response. For investigation, auditory perception experiments for road traffic noise with identical linear SPL were performed by Paired Comparison Method. The numerical results of a Paired Comparison experiment express relative preference about annoyance. So that these relative preference scores are to be correlated to sound quality indices, which are absolute, a transformation is required to go from the relative domain to an absolute and linear scale of preference. The results of the transformation will be the 'merit values,' which quantifies the annoyance(in this case) of the road traffic noise on a linear scale. Using multiple regression, a formula is established that can calculate predicted merit values. Furthermore, This investigation offers a method selecting sound samples that represent various sound quality indices values to use experiment.

  • PDF

Simplified method on measurement and evaluation of floor impact sound using impact ball (임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법)

  • Kim, Yong-Hee;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

Design chart of sound insulation for multiple panels (다중판넬의 차음설계차트)

  • Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.946-949
    • /
    • 2006
  • This study is a trial to make a design chart of sound insulation for multiple panel. Dilatational frequency, ${\Large f}_d$ becomes a key factor for optimal design since it acts like a turning point in sound insulation performance of such panels. Hence, in tuning the ${\Large f}_d$ optimally, elastic modulus of core material and thickness of the skin panel is designated to parameters. Based on these parameter, a design chart of sound insulation for multiple panel is made. Its applicability is proved by the case study of High noise reduction panel.

  • PDF

A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems (병렬 다공판 시스템의 흡음성능에 관한 연구)

  • Hur, Sung-Chun;Lim, Jung-Bin;Ro, Sing-Nam;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.902-907
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and the number of perforated plate. The sound absorbing performances of parallel and series perforated plate systems are compared and discussed from a standpoint of frequency bandwidth with sound absorption. The proposed approach is further extended to the parallel double layer perforated plate system.

  • PDF

An experimental study on the field sound insulation performance of the light weight concrete panel using bottom ash (저회를 이용한 경량패널의 현장 차음성능에 관한 실험 연구)

  • Chung, J.Y.;Jeong, G.C.;Lee, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.65-69
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Because of this reason, dry wall systems are used plentifully. This study examines the sound insulation performance of the light weight concrete panel using bottom ash. There is the difference of airborne sound isolation between laboratory and field test. For the purpose of searching deviation, we use the prediction tool(Insul 6.0). First, we calculated the prediction data and measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the difference.

  • PDF

A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구)

  • Ki, No-Gab;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF