• 제목/요약/키워드: sound vibration

검색결과 2,252건 처리시간 0.026초

바닥충격음 차단성능 평가방법의 KS 규격화 방안 (Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements”)

  • 송민정;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF

바닥마감재가 경량충격음 저감량 평가에 미치는 영향 (A Study on the Reduction of the Lightweight Impact Sound Level by Floor Coverings)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.137-142
    • /
    • 2004
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by floor coverings. The characteristics on the reduction of the lightweight impact sound level by floor coverings is as follows. The insulation level attained by floor coverings tends to be smaller in actual buildings than in public laboratories. The reduction of the impact sound level to the tape is similar to the method of adhesives. For this reason, the reduction of impact sound level by floor coverings in public laboratories can be utilized to tape. And the reduction of impact sound level by floor coverings is not influenced by the size of specimen except the specific frequency.

  • PDF

주기적 구조를 갖는 굴절형 방음판의 흡음성능에 관한 연구 (A Study on the Sound Absorption of Periodically Folded Barriers)

  • 박춘근;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.143-146
    • /
    • 2004
  • This study is aimed to numerically evaluate a sound absorption performance of periodically folded barriers. Based on the formulation for sound absorption of a locally reacting surface in a periodic arrangement, variations of the sound absorption with parameters such as the folded width and depth are investigated. In comparison with the sound absorption of a conventional barrier with a flat surface, it is found that the periodically folded barriers can achieve a higher sound absorption especially in the low frequency range.

  • PDF

공동주택에서 음원특성에 따른 외부창호 차음성능 변화 (Variation of the Sound Insulation Performance of Window in the Apartment House depending on the Sound Source Characteristics)

  • 박현구;이옥균;한동화;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1735-1740
    • /
    • 2000
  • The aim of this study is to analyze the sound insulation performance of windows depending on the sound source types and to propose the noise control method in the apartment house. The regions where apartment houses are constructed are varied in the dominant noise sources such as aircraft noise, railway noise and road traffic noise. For the experiment, nine noise sources including pink noise were selected and recorded, which was used in the experiment by reproducing. As a result of this study, the sound insulation performance of window was found that when the frequency contents of the noise were high level in all frequency bands the difference of sound insulation performance was negligible, but when the frequency contents were low level at particular frequency band the difference of sound insulation performance was shown very differently.

  • PDF

부하변동에 따른 풍력발전기용 증속기의 음향파워 특성 (Characteristics for Sound Power of Wind Turbine Gearbox by Load Variation)

  • 이재정;이승용;서영욱;이진현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.311-315
    • /
    • 2012
  • In these days, promising renewable energy, wind turbine is clean energy but has an environmental pollutant which is noise. Noise assessment is one of the major performance evaluations for wind turbine and nowadays, developing and research for measurement and method of the assessment considering environmental pollutants is being important. Object in this study is that figuring out sound power characteristic of the gearbox for wind turbine through measuring sound intensity. In back-to-back test, we can figure out the noise characteristic of the gearbox for wind turbine through comparing and measuring sound pressure level, sound power level in operating at the each load condition respectively.

  • PDF

기어장치에서 베어링의 설치위치가 소음특성에 미치는 영향 (Effect of Offset of Bearing on Radiation Sound and Vibration in the Gear System)

  • 류성기;이중희
    • 한국안전학회지
    • /
    • 제13권1호
    • /
    • pp.34-39
    • /
    • 1998
  • This paper describes a evaluation method of sound power radiated from the vibrating faces of a single stage gear box using sound radiation. The vibration caused from meshing gears is transmitted to the gear box faces through shafts and bearings. A Boundary Element Method (BEM) is developed to calculate the sound power radiated from the faces with their velocity response which is based on the Building Block Approach (BBA). Radiation efficiency as well as the sound intensity on the surface of the gear box is also calculated. Sound power of the gear box is larger in the case that bearings have offset to the wall of the gear box than that bearings are on the center of the gear box. The sound power increases with the augmentation of the offset.

  • PDF

광 디스크 드라이브 Seek 소음의 음질 평가 (Sound Quality Evaluation of Optical Disc Drive Seek Noise)

  • 이상윤;최명렬;성평용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.401-405
    • /
    • 2003
  • Sound quality is becoming a major concern in optical disc drives (ODD). In order to improve the sound quality of slim type ODDs, we changed lead screw pitch and firmware algorithm in the seek mode. To evaluate the sound quality, the PCM (Paired Comparison Method) was adopted and the result was compared with the time-averaged loudness spectrum. Sound signals were also recorded and modified by increasing or decreasing selected frequency bands to verify their sensitivities to the sound quality. As a result of jury test, preferred frequency bands are associated with the time-averaged loudness spectrum.

  • PDF

비대칭 구조의 설치방법에 따른 차음성능평가 (An evaluation on the sound insulation performance by the install method of asymmetric structure)

  • 최둘;문순성;구희모;김항
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.10-12
    • /
    • 2014
  • In ISO 10140-5:2010, defines the reverberation time conditions of the receiving room. The sound absorption side of test specimen is installed in the source room generally. In this study, examined at the change in the sound insulation characteristics for the test specimen of asymmetric structure attached sound absorbing material by changing the installed position. A difference of sound insulation performance was maxium Rw 1 dB, it is preferable to place the larger sound absorption area in source room.

  • PDF

에어컨 소음의 Sound Quality 평가 (Evaluation of Sound Quality of Air-conditioning Noise)

  • 전진용;유진;김수연
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

차음성능 향상을 위한 발코니 창호의 개발 및 평가 (Development and Evaluation for Improvement of the Sound Insulation of Balcony Window in Apartment)

  • 김하근;김명준;오진균
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.519-526
    • /
    • 2005
  • Recently, the interest on the comfortable dwelling environment is increasing and the effort to solve the problem of exterior noise was tried. The propose of this study is to suggest the design of balcony window in apartment and to evaluate the sound insulation of it. So, we designed five types of balcony window which were considered not only sound insulation but ventilation. The sound reduction index of window was evaluated by the measurement in mock-up room. The results showed that case 2 improved about 6 dB in the weighted apparent sound reduction index than case 1, and case 3 reduced about $39 \%$ in construction cost than case 4.