• Title/Summary/Keyword: sonic

Search Result 596, Processing Time 0.029 seconds

Analytical Study of the Subsonic/Sonic Ejector Flows (아음속/음속 이젝터의 유동에 관한 해석적 연구)

  • 최보규;김희동;김덕줄
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • In order to predict the performance of subsonic/sonic ejector system and to provide fundamental data for a cost effective design, one dimensional gas dynamics theory was applied to the subsonic and sonic ejector systems with the second throat. In the current theoretical analyses, ejector throat area ratio, mass flow ratio and secondary stagnation pressure were derived as a function of the operating pressure ratio of the ejector, and the discharge coefficient of the primary nozzle and the loss coefficient of the diffuser were incorporated into the whole performance of the ejector system. The results of theoretical analysis can be applied to practical industrial use of subsonic and sonic gas ejector systems.

  • PDF

Measurement and prediction of sonic boom by high speed train at the tunnel exit (고속 전철에 의한 터널 출구에서의 충격성 소음(소닉붐)의 예측 및 실험적 연구)

  • 이수갑;윤태석;정원태;이동호;김동현;강신재
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.369-378
    • /
    • 1998
  • When a high-speed train enters a tunnel, a compression wave is generated ahead of the train and propagates along the tunnel. This wave subsequently emerges form the exit portal of the tunnel, which causes an impulsive noise. In the present study, experimental investigation is carried out on the sonic boom noise with parameters of train speed, blockage ratio, nose shape of train and airshaft. These experimental results show that several countermeasures could be used to efficiently reduce the sonic boom. In addition, numerical analysis is performed to predict the sonic boom. The predicted sound waves are in a good agreement with the experimental results.

  • PDF

Effect of turbulence driving and sonic Mach number on Davis-Chandrasekhar-Fermi method

  • Yoon, Heesun;Cho, Jungyeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.44.1-44.1
    • /
    • 2019
  • Davis-Chandrasekhar-Fermi (DCF) method is a tool that is widely used to obtain the strength of the mean magnetic field projected on the plane of the sky. When there are independent eddies along the line of sight, the variation of polarization angle will decrease by the averaging effect. Therefore, the measured strength of the magnetic field can be overestimated. Cho & Yoo (2016) proposed a modified DCF method considering such effect. By using this, we quantitatively compared the results from the conventional DCF and the modified DCF methods for various sonic Mach numbers and driving schemes (the solenoidal and compressive driving). Here, we present that the modified DCF method does not show a strong dependence on the sonic Mach number or driving schemes either, while the conventional DCF method depends on the sonic Mach number for the compressive driving scheme.

  • PDF

EFFECTS OF HEAT-KILLED AND SONIC EXTRACTS OF MICROORGANISM ON CULTURED CELLS (세균액 및 세균단백질 추출물이 배양 세포에 미치는 영향)

  • Yu, Young-Dae;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.606-618
    • /
    • 2000
  • Dental pulp infection is most commonly caused by extensive dental caries, and some bacterial species invade root canals; bacterial components and products are thought to be associated with the pathogenesis of periapical periodontitis. A principle driving force behind pulpal disease response appears to lie in the host immune system's to bacteria and their products. We examined the production of interleukin $1{\beta}$ (IL-$1{\beta}$) and tumor necrosis factor ${\alpha}$(TNF-${\alpha}$) from human peripheral mononuclear cells, lymphocytes and monocytes stimulated by heat-killed Acitnobacillus actinomycetemcomitans (ATCC 29523), Porphyromonas gingivalis (ATCC 33277) and Prevotella intermedia (ATCC 25611), and also by their sonicated bacterial extracts (SBE), respectively. The effects of three strains of heat-killed bacteria and their SBEs on the morphology of cultured blood cell lines HL-60 (KCLB 10240) and J774A.1 (KCLB 40067) were observed under the inverted microscope. Ultrastructural changes of J774A.1 exposed to heat-killed P. intermedia and its SBE were investigated using transmission electron microscopy. Production of IL-$1{\beta}$ was reduced in human peripheral mononuclear cells after stimulation by sonic bacterial extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia. Heat-killed and sonic extract of P. gingivalis inhibited the production of TNF-${\alpha}$ in peripheral mononuclear cells. Production of TNF-${\alpha}$ was inhibited in peripheral monocytes after stimulation by sonic extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia. HL-60 and J 774A.1 cells showed granular degeneration after treatment with heat-killed and sonic extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia Chromatin margination and shrinkage were observed in 774A.1 treated with heat-killed P. intermedia. Cell wall structure and organelles were destroyed and vacuoles were formed in cytoplasm in J774A.1 treated with P. intermedia sonic extract. These results suggest that A actinomycetemcomitans, P gingivalis and P intermedia may have an important role in the formation and progression of pulpal diseases via both modulation of production of IL-$1{\beta}$ and TNF-${\alpha}$ from blood mononuclear cells and cytopathic effects.

  • PDF

Path Planing for a Moving Robot using Ultra Sonic Sensors (초음파 센서를 이용한 이동로봇의 경로 계획)

  • Cha, Kyung-Hwan;Shin, Hyun-Shil;Hwang, Gi-Hyun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Robot collects surrounding information to recognize tile unknown environment by using various sensors such as visual, infrared ray and ultra sonic sensors. Although visual sensor is the most popular one, it has some difficulties in collecting data in dark or too bright environment due to sensitivity of the light. It also requests significant amount of calculation on collecting data from certain images with marked, straight and curved ones. As an alternative, ultra sonic sensor can simply overcome this visual sensing system's flaw and easily be used. It is easier than visual system, especially in case of collecting data on object and distance in dark environment. Ultra sonic sensor can replace the expensive visual sensing system not only in avoiding obstacles but also in reaching to the target area smoothly. The purpose of this paper is to develop the algorithm to optimize the environmental recognition, path planning and free-ranging by minimizing errors caused by inaccurate information and by considering characteristics of the ultra sonic rays such as refraction and diffusion. This paper also realizes the system that can recognize the environment and make the appropriate path planning by applying the algorithm on this moving robot.

  • PDF

A Study on Slowness Time Coherence Application and its Characteristics from Sonic Log Experiment in Model Holes (모형공에서의 음파실험을 통한 STC 기법의 적용과 특성 비교)

  • Kim, Yeong-Hwa;Zhao, Weijun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.299-307
    • /
    • 2007
  • Slowness time coherence (STC) technique has been applied to 3-receiver slim hole sonic log using 3 NX sized concrete model holes of different physical properties. We analyzed the effects of different source center frequencies on the wave forms, their amplitude spectra, and their STC results. We could determine the sonic velocity of each mode accurately by the application of STC method with the semblance projection and efficient selection of center frequency. Theoretical model and experimental model hole studies indicate that 4-receiver condition is the most ideal for STC in near surface slim hole sonic log. The result also indicates that favorable STC result can be obtained from three-receiver sonic log provided with the help of the first arrival picking method.

A Study of the Types of Metaphor Reflected on the Sonic Interactive Objets (동작 기반 인터랙티브 사운드 오브제에 나타난 메타포 유형 연구)

  • Kim, Hee-Eun;Park, Seung Ho
    • Design Convergence Study
    • /
    • v.15 no.2
    • /
    • pp.185-201
    • /
    • 2016
  • This study aims to define the basic design elements of a sonic interactive object and relate them with the different metaphor types including physical metaphor, gestural metaphor, sound metaphor, and embodied metaphor that are reflected on the interface, gesture, sound, and embodied experience. It discusses how the concept mapping can be effectively done by utilizing metaphor and considering the relationships between the types of metaphor when designing a sonic interactive object. This study has a significance in the aspect that it expanded the area of metaphor to embodied experience and subdivided the types of metaphor including visual, sound, gestural and tactile information. Furthermore, it attempted to analyze the design elements of a sonic interactive object in relation to the types of metaphor. A researcher or a designer, therefore, can use this study as a reference to design concept mapping of a sonic interactive object, in a way that the design elements and metaphor types work together effectively to enable a visitor to recognize what they are expected to do with the object more intuitively.

Effectiveness of Sonic and Manual Toothbrush in Preschool Children (미취학 어린이에서 음파 칫솔과 일반 칫솔의 효과)

  • Shin, Youngseob;Lee, Hyoseol;Song, Jeseon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.374-381
    • /
    • 2016
  • The purpose of this study is to compare the effectiveness of sonic and manual toothbrushes using the $L{\ddot{o}}e$ and Silness plaque index (PI). This was an examiner-blind, randomized study with a cross-over design. A total of 34 children (17 males and 17 females) aged 3-6 years were included. Subjects were randomly assigned to two groups: one group used the sonic brush for two weeks before using the manual brush for two weeks, while the other group used the manual brush for two weeks followed by the sonic brush. During each dental visit, plaque indices were recorded and compared to baseline. The results were analyzed using a paired t-test or Pearson correlation test (${\alpha}=0.05$). Thirty children (mean age 4.37 years) complied with the protocol and completed the study. The PI score was 0.09 lower compared to baseline after using a manual toothbrush and 0.26 lower after using the sonic brush. The reduction was statistically significantly greater in the sonic group (p < 0.05). In conclusion, the sonic toothbrush is more effective for reducing plaque than a manual toothbrush.

A Study of Improving Combustion Stability with Sonic Wave Radiation (음파를 이용한 연소 안정성 개선에 관한 연구)

  • Min, Sun-ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.401-406
    • /
    • 2020
  • NOx (nitrogen oxide) in the exhaust gas engines causes severe air pollution. NOx is produced under high-temperature combustion conditions. EGR (exhaust gas recirculation) is normally used to reduce the combustion temperature and NOx production. As the EGR ratio increases, the NOx level becomes low. On the other hand, an excessively high EGR ratio makes the combustion unstable resulting in other air pollution problems, such as unburned hydrocarbon and higher CO levels. In this study, the improvement of fuel droplets moving by the radiation of sonic waves was studied for the stable combustion using analytic and experimental methods. For the analytical study, the effects of the radiation of a sonic wave on the fuel droplet velocity were studied using Fluent software. The results showed that the small droplet velocity increased more under high-frequency sonic wave conditions, and the large droplet velocity increased more under low-frequency sonic wave conditions. For the experimental study, the combustion chamber was made to measure the combustion pressure under the sonic wave effect. The measured pressure was used to calculate the heat release rate in the combustion chamber. With the heat release rate data, the heat release rate increased during the initial combustion process under low-frequency sonic wave conditions.

Calibration of Discharge Coefficient of Sonic Nozzle Using CVFM (정적형 유량계를 이용한 소닉노즐 유출계수 교정 방법에 관한 연구)

  • Shin, J.H.;Kang, S.B.;Park, K.A.;Lim, J.Y.;Cheung, W.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.243-248
    • /
    • 2010
  • Sonic nozzles have been a standard device for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two sonic nozzles of diameter ${\Phi}$ 0.03 mm and ${\Phi}$ 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter(CVFM), readily set up in the Vacuum center of KRISS. was used to calibrate the discharge coefficients of both nozzles. The calibration results were shown to determine them within the 3% expanded measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process in the ranges of 0.6~1,800 cc/min. Those flow conditions are equivalent to the fine gas flow with Reynolds numbers of 26~12,100. Those encouraging results confirm that calibrated sonic nozzles enable precision measurement of extremely low gas flow encountered very often in th vacuum processes. Both calibrated sonic nozzles are proven to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of vacuum pumps in the semiconductor and flat display processes. Furthermore, they can provide other applications to flow control devices in vacuum, such as MFC, etc.