• 제목/요약/키워드: solvent analysis

검색결과 1,351건 처리시간 0.028초

MCV와 RDW를 이용한 복합유기용제 취급 근로자의 빈혈 유형에 관한 조사 (The Type of Anemia in Organic Solvent Workers by MCV and RDW)

  • 김성준;엄상화;김대환;이채언;전진호;김성천;배기택;박형종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제25권2호
    • /
    • pp.162-171
    • /
    • 1992
  • The hematologic effect by low-concentration and repeated exposure to mixed organic solvent remains obscure. This study was performed to evaluate the hematologic effect by mixed organic solvent exposure, especially on the type of anemia by mean corpuscular volume(MCV) and red blood cell distribution width(RDW). The subject were 64 organic solvent workers(male 4, female 60) and 78 general workers(male 18, female 60) who showed anemic tendency in worker's health examination which carried out by Pusan Paik Hospital from January to December, 1988. The author gained some hematologic findings(hemoglobin, hematocrit, RBC, WBC, MCV, MCHC, platelet count, ESR, RDW) from auto-analysis method by coulter counter S plus IV, and compared the type of anemia by MCV and RDW. In the pilot study for estimating the prevalence of anemia according to the type of b, the prevalence rate was higher in organic solvent workers than in public officials as 10.9% and 4.1% respectively. There were statistical significance in the value of hemoglobin, hematocrit, MCV, MCHC, platelet count, ESR, RDW between the two study groups with more severe anemic tendency in organic solvent workers. The type of anemia in organic solvent workers was microcytic and anisocytic with the mean value of $68.28{\pm}8.3fL$ of MCV and $19.1{\pm}4.0%$ of RDW.

  • PDF

교량 스틸박스거더 도장공사의 유기용제 측정 실험 (Measurement of Organic Solvent from Painting Work Inside the Steel Box Girder of Bridge)

  • 이정우;손기상
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.134-142
    • /
    • 2005
  • This study is to find out how organic solvent will be propagated from painting inside the steel box girder of bridge. $2.9m{\times}3.0m$ of inside size of steel box girder is not suitable for painters to do his work comfortably and hygienically. Substance density(ppm)inside the space of the box unsatisfactory hygienical condition. Most of organic solvent(mainly toluene) came down to 0.5m in two minutes and 53sec. But personal protection for painter should be properly kept against flying this heavy organic solvent. longitudinally 27.1m in length is a cell unit of the whole length of bridge. Model XP-3l6A made in Japan is a main instrumentation adjusted to sense organic solvent especially toluene which can be measured up to 10,000ppm. Scenario analysis by computer program, safer release 2.0 has been performed first to estimate how the organic solvent will be propagated. And then actual test was done as a model. This has been measured for approximately five(5) minutes, with 30 sec interval. Actual measurement results showed much higher $10{\sim}20%$ than result analyzed by the computer program, meaning that this painting work can give worse effect to the worker who is painting inside the box girder of the bridge. The first meas urement level over the floor set up at 30cm height from the floor, because organic solvent was estimated to stay at the level. and then, they were measured at 1.0m, 1.5m level respectively, more.

Solvent 별 분산에 따른 Milled Carbon Fiber의 배열성 연구 (Effect of the Alignment of Milled Carbon Fiber Dispersed in Various Solvents)

  • 이성권;최성웅
    • Composites Research
    • /
    • 제35권1호
    • /
    • pp.47-51
    • /
    • 2022
  • 전자기기 발열을 효율적으로 제어하기 위해 열전도성 복합재료에 대한 많은 연구가 진행되고 있다. 본 연구에서는 solvent 별 분산에 따른 carbon fiber의 배열성 관계를 알아보기 위해 Milled Carbon Fiber를 4가지 Solvent에 분산하고 Vacuum filtration 방법을 통해 탄소섬유강화 복합재료(CFRP)를 제작하였다. CFRP의 배열성을 알아보기 위해 광학현미경 관측과 섬광법을 통한 열전도도를 측정하였다. NMP와 Ethanol을 Solvent로 사용하여 성형한 CFRP의 평면두께방향 열전도도가 각각 10.79 W/mK, 10.57 W/mK 값을 보였고 이는 평면내부방향 열전도도에 비해 218%, 209% 향상된 결과를 보였다. Solvent의 상대적으로 높은 점도 값은 solvent 유체의 높은 전단력에 영향을 주어 성형 시 필러의 배열성을 결정하는데 영향을 주는 것으로 판단된다.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • 제4권1호
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

3급 아민염 및 4급 암모늄염의 Tetrathiocyanatocobaltate[II]에 의한 분석화학적 연구 (Studies on the Chemical Analysis of the Tertiary Amine Salt and Quaternary Ammonium Salt by Tetrathiocyanatocobaltate[II])

  • 엄동옥;이윤중
    • 약학회지
    • /
    • 제24권3_4호
    • /
    • pp.159-165
    • /
    • 1980
  • Tetrathiocyanatocobaltate[II] forms complexes with tertiary amine salts or quarternary ammonium salts which were extractable from aqueous solution by organic solvent. In order to study composition of the complex, the colored crystalline complexes produced were evaluated with elemental analysis, infrared and mass spectra. And also a novel spectrophotometric method for the determination of tertiary amine salt or quarternary ammonium salt with tetrathiocyanatocobaltate[II] was established by organic solvent extraction within coefficient of variation of 1.06-1.35%.

  • PDF

Influence of ionic liquid additives on the conducting and interfacial properties of organic solvent-based electrolytes against an activated carbon electrode

  • Kim, Kyungmin;Jung, Yongju;Kim, Seok
    • Carbon letters
    • /
    • 제15권3호
    • /
    • pp.187-191
    • /
    • 2014
  • This study reports on the influence of N-butyl-N-methylpyrrolidinium tetrafluoroborate ($PYR_{14}BF_4$) ionic liquid additive on the conducting and interfacial properties of organic solvent based electrolytes against a carbon electrode. We used the mixture of ethylene carbonate/dimethoxyethane (1:1) as an organic solvent electrolyte and tetraethylammonium tetrafluoroborate ($TEABF_4$) as a common salt. Using the $PYR_{14}BF$ ionic liquid as additive produced higher ionic conductivity in the electrolyte and lower interface resistance between carbon and electrolyte, resulting in improved capacitance. The chemical and electrochemical stability of the electrolyte was measured by ionic conductivity meter and linear sweep voltammetry. The electrochemical analysis between electrolyte and carbon electrode was examined by cyclic voltammetry and electrochemical impedance spectroscopy.

Solvent Effect on the Dynamics of Radical Ion Pair Separation

  • Han, Chul-Hee
    • Journal of Photoscience
    • /
    • 제8권1호
    • /
    • pp.33-37
    • /
    • 2001
  • Picosecond absorption spectroscopy has been employed in the study of the solvent dynamics of 1, 2, 4, 5-tetracyanobenzene/biphenyl derivative radical ion pairs, and the resulting rates of radical ion pair separation are faster in acetonitrile than in dichloromethane. In an effort to account quantitatively for such solvent effect on the rate of radical ion pair separation, an equation for the rate of radical ion pair separation is introduced, in which the rate depends exponentially on the electrostatic interaction energy in the radical ion pair. In our analysis of the types of electrostatic interaction energy based on the conducting spheres in dielectric continuum was chosen, and the rate equation employing this electrostatic energy provided information on the distance on the distance of radical ion pair separation and solvation energy of the radical ion pair, thereby providing quantitative explanation for the observed solvent effect on the rate of radical ion pair sepaaration.

  • PDF

고순도 용제 회수 시스템의 공정 조건 탐색을 위한 AMESim 모델 개발 (Developing AMESim Model to Find out Process Condition of High Purity Solvent Recovery System)

  • 김대현;주강우;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.8-12
    • /
    • 2015
  • As NMP (N-Methyl-2pyrrolidone) is becoming important in many fields, the demand for it is also rising rapidly. With its chemical property of high boiling point, low vapor pressure and high water solubility, it is easy to recover it after processing. Therefore, it is increasingly needed to develop a system that effectively recovers NMP solvent. The study produced a system modeling using AMESim software before developing high purity solvent recovery (HPSR) system to recover NMP solvent. Then, it verified reliability by comparing the simulation model with the test result.