• 제목/요약/키워드: solvent analysis

Search Result 1,351, Processing Time 0.028 seconds

Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process (분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계)

  • Lee, Seung-Hyun;Zo, Moon-Shin;Lee, Moon-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

Quantitative Approaches for the Determination of Volatile Organic Compounds (VOC) and Its Performance Assessment in Terms of Solvent Types and the Related Matrix Effects

  • Ullah, Md. Ahsan;Kim, Ki-Hyun;Szulejko, Jan E.;Choi, Dal Woong
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • For the quantitative analysis of volatile organic compounds (VOC), the use of a proper solvent is crucial to reduce the chance of biased results or effect of interference either in direct analysis by a gas chromatograph (GC) or with thermal desorption analysis due to matrix effects, e.g., the existence of a broad solvent peak tailing that overlaps early eluters. In this work, the relative performance of different solvents has been evaluated using standards containing 19 VOCs in three different solvents (methanol, pentane, and hexane). Comparison of the response factor of the detected VOCs confirms their means for methanol and hexane higher than that of pentane by 84% and 27%, respectively. In light of the solvent vapor pressure at the initial GC column temperature ($35^{\circ}C$), the enhanced sensitivity in methanol suggests the potential role of solvent vapor expansion in the hot injector (split ON) which leads to solvent trapping on the column. In contrast, if the recurrent relationships between homologues were evaluated using an effective carbon number (ECN) additivity approach, the comparability assessed in terms of percent difference improved on the order of methanol (26.5%), hexane (6.73%), and pentane (5.24%). As such, the relative performance of GC can be affected considerably in the direct injection-based analysis of VOC due to the selection of solvent.

Further Kinetic Studies of Solvolytic Reactions of Isobutyl Chloroformate in Solvents of High Ionizing Power Under Conductometric Conditions

  • Lim, Gui Taek;Lee, Yeong Ho;Ryu, Zoon Ha
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.615-621
    • /
    • 2013
  • Solvolyses of isobutyl chloroformate (4) in 43 binary solvent mixtures including highly aqueous media, water, $D_2O$, $CH_3OD$, 2,2,2-trifluoroethanol (TFE) as well as aqueous 1,1,1,3,3,3-hexafluoro-isopropanol (HFIP) solvents were performed at $45^{\circ}C$, in order to further investigate the recent results of D'Souza, M. $J^1$. et al.; solvolyses of 4 are found to be consistent with the proposed mechanism ($Ad_E$). The variety of solvent systems was extended to comprise highly ionizing power solvent media ($Y_{Cl}$ > 2.7 excepted for aqueous fluorinated solvents and pure TFE solvent) to investigate whether a mechanistic change occurs as solvent compositions are varied. However, in case of 18-solvent ranges having aqueous fluorinated solvent systems (TFE-$H_2O$ and HFIP-$H_2O$) and/or having $Y_{Cl}$ > 2.7 solvent systems, the solvent effect on reactivity for those of 4 are evaluated by the multiple regression analysis as competition with $S_N2$ - type mechanism. And in pure TFE and 97 w/w % HFIP solvents with high $Y_{Cl}$ and weak $N_T$, these solvolyses are understood as reactions which proceed through an ionization ($S_N1$) pathway.

Preferential Solvation and Statistical Analysis for Solvent Polarity Parameters in MeOH Binary Mixtures

  • Sakong Yeol;Yoo Seoung-Kyo;Lee Ikchoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.6
    • /
    • pp.636-642
    • /
    • 1992
  • Preferential solvation (PS) phenomena of solutes based on solvent polarity, $E_T$ and AN, were studied by UV/vis. and NMR spectra in MeOH binary mixtures. According to the extent of solvent-solvent interaction, different solvation phenomena were found. PS concept was applied to explain the reactivity of tert-butyl halides solvolysis. The findings of solvation phenomena have been related to the rate of solvolysis and PS suggested as a reason for the solvent dependence of the rates of reaction. Moreover, we found that the results of principal components analysis using six parameters are in good accordance with the results of PS phenomena in mixed methanol systems.

Extraction Methods of Organic Components from Rubber Composites and Analysis of the Extract Using Gas Chromatography/Mass Spectrometry

  • Chae, Eunji;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.54 no.3
    • /
    • pp.188-200
    • /
    • 2019
  • Rubber articles contain various organic additives such as antidegradants, curing agents, and processing aids. It is important to extract and analyze these organic additives. In this paper, various extraction methods of organic additives present in rubber composites were introduced (solvent extraction, Soxhlet extraction, headspace extraction, and solid-phase microextraction), and the extracts were characterized using gas chromatography/mass spectrometry (GC/MS). Solvent and Soxhlet extractions are easy-to-perform and commonly used methods. Efficiency of solvent extraction varies according to the type of solvent used and the extraction conditions. Soxhlet extraction requires a large volume of solvent. Headspace sampling is suitable for extracting volatile organic compounds, while solid-phase extraction is suitable for extracting specific chemicals. GC/MS is generally used for characterizing the extract of a rubber composite because most components of the extract are volatile and have low molecular weights. Identification methods of chemical structures of the components separated by GC column were also introduced.

Organic solvent exposure for the chronic kidney disease: updated systematic review with meta-analysis

  • Chaeseong Lim;Hyeoncheol Oh
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.11.1-11.17
    • /
    • 2023
  • Background: Studies on the relationship between organic solvent exposure and chronic kidney disease (CKD) have presented inconsistent results. Definition of CKD has changed in 2012, and other cohort studies have been newly published. Therefore, this study aimed to newly confirm the relationship between organic solvent exposure and CKD through an updated meta-analysis including additional studies. Methods: This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. The search was conducted on January 2, 2023 using Embase and MEDLINE databases. Case-control and cohort studies on the relationship between organic solvent exposure and CKD were included. Two authors independently reviewed full-text. Results: Of 5,109 studies identified, a total of 19 studies (control studies: 14 and cohort studies: 5) were finally included in our meta-analysis. The pooled risk of CKD in the organic solvent exposed group was 2.44 (1.72-3.47). The risk of a low-level exposure group was 1.07 (0.77-1.49). The total risk of a high-level exposure group was 2.44 (1.19-5.00). The risk of glomerulonephritis was 2.69 (1.18-6.11). The risk was 1.46 (1.29-1.64) for worsening of renal function. The pooled risk was 2.41 (1.57-3.70) in case-control studies and 2.51 (1.34-4.70) in cohort studies. The risk of subgroup classified as 'good' by the Newcastle Ottawa scale score was 1.93 (1.43-2.61). Conclusions: This study confirmed that the risk of CKD was significantly increased in workers exposed to mixed organic solvents. Further research is needed to determine the exact mechanisms and thresholds. Surveillance for kidney damage in the group exposed to high levels of organic solvents should be conducted.

Recovery of Zinc in Spent Pickling Solution with Oxalic Acid

  • Lee, Kyung-Ran;Kim, Jeongsook;Jang, Jeong-Gook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.785-790
    • /
    • 2017
  • To collect zinc, Fe and Zn in spent pickling solution were extracted by using TBP (tributyl phosphate), and Zn was recovered from extracted solution to zinc oxalate particles by oxalic acid solution. The reusability of TBP solvent was also tested. The distribution coefficient of Zn was not affected by the concentration of Fe in spent pickling solution, almost constant with the values of 7.12~9.31 when extracted by TBP solvent. It was found that the extraction capacity of TBP solvent for Zn is higher than that for Fe. The extraction efficiency of Zn was higher than 95%, while most of Fe was left in aqueous phase. After the recovery, the used TBP solvent could be repeatedly reused for the extraction of Zn up to eight times. XRD analysis showed that zinc oxalate ($ZnC_2O_4$ $2H_2O$) was formed from the reaction of Zn-TBP and oxalic acid. From the results of SEM analysis, the formation of zinc oxalate particle was strongly affected by the concentration of oxalic acid. In summary, Zn in spent pickling solution was successfully separated and recovered with TBP solvent and oxalic acid solution, respectively.

Development of Atomization Spraying System for Solvent-free Paints(II) - Structural Analysis of Hydraulic Actuator - (무용제 도료용 무화 분사시스템 개발(II) - 유압 엑츄에이터의 구조해석 -)

  • Kim, Dong-Keon;Kim, Bong-Hwan;Shin, Sun-Bin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.67-72
    • /
    • 2011
  • Solvent-free paint is sprayed from higher-pressure conditions, because the viscosity is large. The hydraulic actuator which can be operated under higher-pressure condition is required to spray solvent-free paints in painting process for the environmental protection. The purpose of this paper is to develop the hydraulic actuator under higher-pressure conditions for solvent-free paint spraying system. The hydraulic actuator consists of inner spool, outer spool and ball. The analysis of a structural stability was conducted by using ANSYS V11 under the design condition of upward and downward movement of spool. As a result, the maximum von-Mises stress applied on spool under 4mm displacement showed a value of 106MPa which was greater than the allowable stress of the spool with a value of 250MPa and a value of safety factor 3. This result suggested that the spool system be unstable under the design condition so that it was necessary for the spool system to be reinforced to secure the structural stability.

Effect of Dihydroxybenzoic Acid Isomers on the Analysis of Polyethylene Glycols in MALDI-MS

  • Lee, Ae-Ra;Yang, Hyo-Jik;Kim, Yang-Sun;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1127-1130
    • /
    • 2009
  • The effects of different dihydroxybenzoic acid (DHB) isomers, when used as matrix materials in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), were investigated in analyses of polyethylene glycol (PEG) polymers. PEG polymers ranging from 400 to 8,000 Da were prepared in different DHB isomer matrices using solvent-based and solvent-free methods. PEG samples were detected only in matrices of 2,3-DHB, 2,5-DHB, and 2,6-DHB while the most intense peaks were observed using 2,6-DHB in both solvent-free and solvent-based preparations.

Solvent Extraction of Cobalt Chloride from Strong Hydrochloric Acid Solutions by Alamine336 (진한 염산용액에서 Alamine336에 의한 염화코발트의 용매추출)

  • Lee, Man-seung;Lee, Jin-Young
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.4
    • /
    • pp.227-232
    • /
    • 2008
  • Solvent extraction reaction of cobalt by Alamine336 from strong hydrochloric acid solution was identified by analyzing the solvent extraction data reported in the literature. Analysis of the data by graphical method revealed that Alamine336 took part in the solvent extraction reaction as a monomer in the concentration ranges, [Co(II)] : 0.0169 - 0.102 M, [Alamine336] ; 0.02- 1.75 M, and [HCl ] : 5 - 10 M. The following solvent extraction reaction and equilibrium constant was obtained from the experimental data by considering the activity coefficients of chemical species present in the aqueous phase. $Co^{2+}+2Cl^{-}+R_3NHCl_{org}=CoCl_3\;R_3NH_{org}$, $K_{ex}=2.21$ The distribution coefficients of cobalt predicted in this study agreed well with those reported in the literature.