• 제목/요약/키워드: solution leakage

검색결과 404건 처리시간 0.019초

키로깅을 통한 정보유출 실시간 탐지 솔루션 설계 및 구현 (A Design and Implementation of a Solution for Real Detection of Information Leakage by Keylogging Attack)

  • 최인영;최지훈;이원열
    • 한국멀티미디어학회논문지
    • /
    • 제17권10호
    • /
    • pp.1198-1204
    • /
    • 2014
  • Most of vaccine type security solutions detect intrusion of computer virus or malicious code. However, they almost don't have functionalities of the information leakage detection. In particular, information leakage through keylogging attact cannot be detected. In this paper, we design and implement a solution to detect the leakage of information through keylogging attact. Proposed solution detects the user-specified information in real time. To detect the leakage of user-specified information, the solution extracts the payload field from each outbound packet and compares with user-specified information. We design the solution to reduce the effect on the packet transmission delay time due to packet monitoring operation. And we design a simple user interface. By proposed solution, user can response to intrusion or information leakage immediately because he or she can perceives a leakage of information in real time.

A Leakage-Based Solution for Interference Alignment in MIMO Interference Channel Networks

  • Shrestha, Robin;Bae, Insan;Kim, Jae Moung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권2호
    • /
    • pp.424-442
    • /
    • 2014
  • Most recent research on iterative solutions for interference alignment (IA) presents solutions assuming channel reciprocity based on the suppression of interference from undesired sources by using an appropriate decoding matrix also known as a receiver combining matrix for multiple input multiple output (MIMO) interference channel networks and reciprocal networks. In this paper, we present an alternative solution for IA by designing precoding and decoding matrices based on the concept of signal leakage (the measure of signal power that leaks to unintended users) on each transmit side. We propose an iterative algorithm for an IA solution based on maximization of the signal-to-leakage-and-noise ratio (SLNR) of the transmitted signal from each transmitter. In order to make an algorithm removing the requirement of channel reciprocity, we deploy maximization of the signal-to-interference-and-noise ratio (SINR) in the design of the decoding matrices. We show through simulation that minimizing the leakage in each transmission can help achieve enhanced performance in terms of aggregate sum capacity in the system.

옥외 애자용 재료의 표면 전기전도 특성 (Electrical Conduction Properties of Surface in Materials for Outdoor Insulator)

  • 박영국;이운석;정수현;장동욱;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.758-762
    • /
    • 1998
  • Electrical conduction property of insulator surface is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the materials to be used for outdoor insulator such as porcelain, EPDM, silicone rubber was discussed by measuring properties of average leakage current and scintillation discharge pulses under salt fog conditions. The fog was applied by nozzle in chamber and fogging fluids were deionized distilled water, 0.5wt% NaCI solution and 2wt% NaCl solution. The average leakage current showed linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage were much different to those in case of dry and clean condition with 2wt% salt fog. In case of slat fog pollution condition, the leakage current was increased above critical voltage. the scintillation discharges were also activated at the level. The leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구 (A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete)

  • 권시원;오미현;곽규성;오상근
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

복합(複合) resin의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (A STUDY ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN)

  • 조진호
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.131-138
    • /
    • 1981
  • The purpose of this study was to evaluate the marginal leakage of composite resin. Preparing 144 class V cavities on freshly extracted noncarious teeth, composite resins were prepared and inserted by one dentist according to the manufacturer's instructions. The experiments were performed in two different groups; In group I; Class V cavities with $90^{\circ}$ cavosurface angle, In group II; Class V cavities with $135^{\circ}$ cavosurface angle. And each group was divided 2 subgroups; In control group; composite resin restoraions without acid etch technique. In experimental group; composite resin restorations with acid etch technique. All specimens were immersed in 0.05% crystal violet solution. Before examination, the restored teeth were subjected to thermal stress. The specimens were sectioned occlusogingivally through the center of the restorations with a diamond disk. The sections were examined under a reflected light microscope at 1 day, 7 days and 30 days after immersing the specimens in dye solution. The results were as follows; 1. Control group of group I and group II showed marginal leakage. 2. The degree of marginal leakage in experimental group was greater reduced than control group. 3. In control group, the degree of marginal leakage in group I was greater than group II. 4. In experimental group, there is not statistical differences of the degree of marginal leakage between group I & group II.

  • PDF

A Study on the Leakage Current Voltage of Hybrid Type Thin Films Using a Dilute OTS Solution

  • Kim Hong-Bae;Oh Teresa
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.21-25
    • /
    • 2006
  • To improve the performance of organic thin film transistor, we investigated the properties of gate insulator's surface according to the leakage current by I-V measurement. The surface was treated by the dilute n-octadecyltrichlorosilane solution. The alkyl group of n-octadecyltrichlorosilane induced the electron tunneling and the electron tunneling current caused the breakdown at high electric field, consequently shifting the breakdown voltage. The 0.5% sample with an electron-rich group was found to have a large leakage current and a low barrier height because of the effect of an energy barrier lowered by, thermionic current, which is called the Schottky contact. The surface properties of the insulator were analyzed by I-V measurement using the effect of Poole-Frankel emission.

  • PDF

다층건물 사용자의 누수확대 방지용 비상배수설비 설치에 대한 의견 연구 (A Study on Multi-story Building Users' Opinions about the Installation of Emergency Plumbing Equipment for Preventing the Spread of Water Leakage)

  • 연철수;서진형
    • 한국주거학회논문집
    • /
    • 제27권4호
    • /
    • pp.59-66
    • /
    • 2016
  • The purpose of this study is to examine the necessity of 'emergency plumbing equipment for preventing the spread of water leakage'. It reviews social and economic costs when there is spread of water leakage and finds out that those are enormous. Expansion of water leakage causes conflicts between neighbors, economic loss and inconvenience from damages on facilities like elevator and power failure. Next, it examines the inability of existing plumbing equipment when it comes to spread of water leakage. Newly defined 'Surface Leakage' means rapid leak in the surface, and 'Internal Leakage' means seeping out slowly and gradually buried in the pipeline. It will also be analyzed by separating the concept of a leak in the two concepts of a 'Surface Leakage' and 'Internal Leakage'. It proposes emergency plumbing equipment for preventing the spread of water leakage as a solution for the expansion of water leakage. It explains general concepts of emergency plumbing equipment for preventing the spread of water leakage. It will also examine the effectiveness of the user by performing a survey of 420 multi-level building their opinion on the effects of an emergency plumbing equipments to prevent the spread of water leakage.

PC보안솔루션 로그분석을 통한 보안정책 제안 (개인정보유출 방지) (Security Policy Proposals through PC Security Solution Log Analysis (Prevention Leakage of Personal Information))

  • 채현탁;이상진
    • 정보보호학회논문지
    • /
    • 제24권5호
    • /
    • pp.961-968
    • /
    • 2014
  • 내부자에 의한 개인정보유출 사고를 방지하기 위하여 다수의 기업은 문서 DRM(Digital Right Management), DLP(Data Loss Prevention), 개인정보 검색시스템 등과 같은 PC보안솔루션을 지속적으로 도입하여 운영하고 있다. 하지만 이러한 투자에도 불구하고 개인정보유출 사건들은 지속적으로 발생하고 있다. PC보안솔루션의 단순 구축이 아닌 기업에 적합한 보안 정책을 사전에 수립하고 정책에 맞는 시스템을 운영한다면 개인정보유출 사고를 미연에 방지할 수 있을 것이다. 또한 로그분석을 통하여 수립한 보안정책의 효과성을 검증할 수 있으며 로그분석결과를 바탕으로 보안정책의 수정 보완이 가능할 것이다. 본 논문은 다양한 PC보안솔루션 중 개인정보유출 방지를 위해 PC에 필수 설치되는 보안솔루션을 정의하고, 필수보안 솔루션을 개인정보보호 관점에서 통합 운영하는 방안, 그리고 로그분석을 통해 개인정보유출 사고 방지를 위한 효과적인 보안정책을 제안하고자 한다.

배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발 (Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks)

  • 최종섭;;안효원
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

편심된 펌프 실의 누설 및 회전체동역학적 해석 (Rotordynamic and Leakage Analysis for Eccentric Annular Seal)

  • 하태웅
    • 한국유체기계학회 논문집
    • /
    • 제4권2호
    • /
    • pp.15-21
    • /
    • 2001
  • Basic equations and their solution procedure we derived for the analysis of an annular pump seal in which the rotor has a large static displacement from the centered position. The Bulk-flow is assumed for a control volume set in the seal clearance and the flow is assumed to be completely turbulent in axial and circumferential direction. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses in the control volume. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about an eccentric position. Flow variables are expanded by using Fourier series for the solution procedure. Integration of the resultant first-order pressure distribution along and around the seal defines the 12 elements of rotordynamic coefficients of the eccentric annular pump seal. The results of leakage and rotordynamic coefficients aye presented and compared with the Marquette's experimental results and the San Andres' theoretical analysis.

  • PDF