• Title/Summary/Keyword: solid-phase extraction (SPE)

Search Result 200, Processing Time 0.028 seconds

Application of Solid Phase Microextraction to the Analysis of Pesticides in Vegetables

  • Cho Tae-Hee;Kang Hee-Gon;Kim Tae-Rang;Chang Min-Su
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.171-174
    • /
    • 2001
  • Solid phase micro-extraction (SPME), a solvent-free, rapid and inexpensive method for the extraction of organic compounds from aqueous sample matrices, was evaluated for determination of the 120 pesticides in vegetables such as crown daisy, perilla leaf, leafy lettuce and to mato. The analysis conditions were chosen for the SPME method: 15 min of immersion of the PDMS fiber in 10 ml of the solution with stirring at 1,000 rpm. The recovery tests were carried out in triplicate. The range of recoveries was 0-142% for organochlorine pesticides and $4.9\sim200\%$ for organophosphorus pesticides. The recoveries were very low in the pesticide groups with low solubility in water. The recoveries became lower in proportion to the interference materials in vegetables. The recovery in tomato was relatively higher than that in perilla Ie af and crown daisy. The recovery values obtained by SPE and SPME were compared. In leaf y lettuce, recovery obtained by SPE method ranged from $58.1\%\;to\;136.1\%$ and recovery by SPME ranged from $9.6\%\;to\;176.3\%$ In organophosphorus pesticides. The recovery in SPME method was satisfactory with $136\%$ for ethoprophos, $119\%$ for methidathion and $113\%$ for diazinon. Meanwhile, recovery of EPN, phenthoate and 2,4-DDT revealed relatively low value of $38\%,\;41\%\;and\;3.4\%,$ respectively. However, most of pesticides applied to SPME method sho wed constant recovery and precision. From these results, it can be concluded that solid phase micro-extraction might be an appropriate method for the screening test of pesticides in vegetables.

  • PDF

Efficiency of Silver Ion-Silica Solid Phase Extraction for Elimination of Sulfur Compounds during Pesticide Multiresidue Analysis in Allium Species (파속류의 잔류농약분석과정에서 silver ion-silica solid phase extraction에 의한 황화합물의 제거 효율성)

  • Park, Jin-Woo;Moon, Kyung-Mi;Choi, Young-Whan;Lee, Young-Guen
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.60-65
    • /
    • 2010
  • Since organic sulfur compounds respond to GC/ECD sensitively, they interfere with quantitative separation of pesticides during residual pesticide analysis of Allium species. In this study, it was intended to develop a rapid and simple method for pesticide multi-residues analysis through clean-up and interferences by a solid-phase extraction (SPE). An SPE method employing silver nitrate impregnated Florosil cartridge was developed and evaluated for the elimination of sulfur compounds from the test solution of Allium species during pesticide residues analysis. The silver nitrate impregnated Florosil cartridge was prepared by efflux of 3 ml of 20% silver nitrate solution through Florosil cartridge (1 g packing, 6 ml tube). The extracts equivalent to 2, 4 6, and 10 g of each sample were loaded onto the cartridge and allowed to exude, and then the exudations were analyzed by GC/ECD. More than 95% of sulfur compounds were removed from the loaded extracts equivalent, up to 6 g in onion, 4 g in spring onion and 4 g in shallot, respectively. 40 pesticides were spiked in the Allium species and loaded onto the cartridge to determine the recoveries; from this, the recoveries of 34 pesticides were within 70~120%.

Analysis of tetracyclines in shrimp samples based on a two-step extraction approach prior to high-performance liquid chromatography

  • Thinnakorn Sukkhunthod;Thanakorn Pluangklang;Sumita Boonnab;Sira Sansuk;Phitchan Sricharoen;Maliwan Subsadsana
    • Analytical Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.211-219
    • /
    • 2024
  • This study presents a sensitive and reliable method for determining tetracycline (TC), oxytetracycline (OTC), and chlortetracycline (CTC) residues in shrimp samples. A two-step process involving liquid-liquid extraction (LLE) followed by solid-phase extraction (SPE) was developed prior to HPLC analysis. The target analytes were effectively extracted using EDTA/McIlvaine buffer (pH 4.0): methanol (80:20, %v/v), with subsequent clean-up using a C18 SPE cartridge. HPLC separation was conducted on a C18 column (250 mm × 4.6 mm i.d., 5 ㎛) at 30 ℃, using 0.01 % trifluoroacetic acid (A) and acetonitrile (B) as the mobile phase. A gradient elution protocol was applied, transitioning from 85(A):15(B) %v/v to 70(A):30(B) %v/v at 7 min, with a 5 min hold, followed by adjustment to 85(A):15(B) %v/v for 13-14 min. The detection was performed using photodiode array (PDA) at 365 nm with a flow rate of 1.0 mL/min. The calibration curves exhibited good linearity within a concentration range of 0.4-6.0 ㎍/mL (R2 > 0.995). The limits of detection (LOD) for TC, OTC, and CTC in shrimp were 0.034, 0.029, and 0.021 ㎍/mL, respectively. The limits of quantitation (LOQ) for TC, OTC, and CTC were found to be 0.114, 0.097, and 0.071 ㎍/mL, respectively. Recoveries of TC, OTC, and CTC from spiked shrimp samples ranged from 91.0 % to 95.5 %, 92.4 % to 97.2 %, and 93.3 % to 96.6 %, respectively. This method was successfully applied to the determination of TC, OTC, and CTC residues in shrimp samples sourced from various local markets.

Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS (고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Although liquid-liquid extraction (LLE) method has been used routinely for the analysis of amphetamine-like drugs (amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA), a solid-phase extraction (SPE) method, which can be automated, was applied for the simultaneous determination by GC/MS in human urine. Urine samples (3 mL) and 0.1 M phosphate buffer (1 mL, pH 7.0) were extracted by an automated SPE system. The eluent was evaporated, derivatized with trifluoroacetic anhydride (TFAA), and analyzed by GC/MS. The calibration curves was linear with correlation coefficient ($r^2$) above 0.994 in the ranges of 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL for AP, MDA, and 50.0~2000.0 ng/mL for MA, MDMA, and MDEA. The limits of detection ranged from 4.0 to 10.0 ng/mL, and the limits of quantitation ranged from 12.0 to 34.0 ng/mL. The relative recoveries were 93.5~107.7 %. The precisions and accuracies were 1.9~14.8 % and -8.7~14.8 %, respectively. The present method was successfully applied to identify the MA or Ecstasy (MDMA) abusers in exact as well as rapid.

Optimization of analytical conditions for the determination of nitrosamines in chlorinated tap water by high performance liquid chromatography (액체크로마토그래피를 이용한 수돗물 중 nitrosamine 화합물 분석의 최적화)

  • Han, Ki-Chan;Kim, He-Kap
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.551-559
    • /
    • 2010
  • This study was conducted to establish an analytical method for the determination of seven nitrosamines in chlorinated tap water by precolumn derivatization followed by high performance liquid chromatography coupled with fluorescence detection. The derivatization procedure was optimized for denitrosation and dansylation, and then two extraction methods, liquid-liquid extraction (LLE) with dichloromethane and solid phase extraction (SPE), were compared. The SPE method employing the optimized derivation procedure showed higher extraction recovery (54.4-88.7%) and reproducibility (1.9-19.4%) than the LLE method (51.4-87.7% and 4.2-33.3%, respectively). The method detection limits were between 0.5 and 4.4 ng/L. When chlorinated water samples were collected from two treatment plants and ten household taps, and analyzed for nitrosamines, Nnitrosodimethylamine (NDMA) was the major compound found between 26.1 and 112 ng/L.

Determination of 4 Parabens in Human Urine by Online SPE and LC-MS/MS Techniques (온라인 고체상추출과 LC-MS/MS 기술을 이용한 소변 중 파라벤류 분석)

  • Kim, Jung Hoan;Kho, Young Lim;Kim, Pan Gyi;Jeong, Jee Yeon;Lee, Eun Hee;Lee, Seung-Youl;Nam, Hye-Seon;Rhee, Gyu-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.561-567
    • /
    • 2012
  • Objectives: Parabens are widely used as antimicrobial agents in pharmaceuticals and cosmetics as well as by the food industry. Parabens have been reported to show weak estrogenic activity and be related to health effects such as allergic reactions and skin and breast cancer. We evaluated an online solid phase extraction (SPE) method coupled with LC-MS/MS technique using free and conjugated parent parabens in human urine for assessing human exposure to parabens. Methods: We employed LC/MS/MS through online solid phase extraction and column-switching techniques and analyzed free and conjugated parabens as biomarkers of human exposure. Four major parabens, methyl-paraben (MP), ethyl-paraben (EP), propyl-paraben (PP) and butyl-paraben (BP), were analyzed. Method validation was performed by sensitivity, accuracy, precision and comparison of the results of online SPE with offline SPE. Results: The limits of detection (LOD) were in the range of 0.2-2 ng/mL, and actual limits of quantification (LOQ) were in the range of 0.7-6 ng/mL urine, depending upon the compound. Accuracy was in the range of 98.3-106.4%, and precision was in the range of 1.3-8.7% (CV) depending upon the compound. We found a good correlation between the results of analysis by online SPE method and that by off-line SPE method. Conclusions: The online SPE method showed proper LOD and validated accuracy, precision and good correlation with the offline method for analyzing parabens in urine.

Determination of Cholesterol in Milk and Dairy Products by High-Performance Liquid Chromatography

  • Oh, H.I.;Shin, T.S.;Chang, E.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1465-1469
    • /
    • 2001
  • A sensitive high-performance liquid chromatographic method was developed to determine the content of cholesterol in milk and dairy products. To optimize separation of cholesterol, mobile phases including acetonitrile:2-propanol (8:1, v/v), acetonitrile:methanol (3:1, v/v), and acetonitrile:methanoI:2-propanol (7:3: I, v/v/v) were compared. Acetonitrile/methanol/2-propanol was superior to the other mobile phase systems for separating cholesterol. Liquid-liquid extraction (LLE) of cholesterol was simplified using a non-polar solvent, hexane, to remove interfering compounds, and had an excellent recovery $(100{\pm}1.0%)$ of cholesterol. A solid phase extraction (SPE) method using Sep-pak $C_{18}$ was developed and compared with LLE. The SPE method was rapid and highly reproducible. Both extraction methods were useful when used in combination with saponification of esterified cholesterol to facilitate total cholesterol determination. The detection limit of cholesterol was $0.01{\mu}g$. The newly developed HPLC method was rapid, simple, and accurate, and has advantages over the many methods commonly used.

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Simultaneous quantitation of enalapril and enalaprilat in human plasma by high-throughput solid phase extraction and liquid chromatography/tandem mass spectrometry

  • Son, Jung-Hyun;Lee, Jae-Ick;Kim, Dong-Hyun
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.401.3-402
    • /
    • 2002
  • Enalapril (ENP) maleate is effective drug for the treatment of renivascular hypertension and heart failure. ENP acts as inhibitor of the enzyme angiotensin-convertase (ACE-inhibitor) and metabolized to enalaprilat (ENPT), which is the active metabolite that is really responsible for the therapeutic action. In the present study, a sensitive and rapid liquid chromatography/ electrospray ion trap tandem mass spectrometry (LC/MS/MS) method combined with high-throughput solid phase extraction (SPE) has been developed and validated for the simultaneous quantitative determination of ENP and ENPT in human plasma. (omitted)

  • PDF