• Title/Summary/Keyword: solid state detector

Search Result 60, Processing Time 0.025 seconds

Analysis of the oscillation condition optimized at laser-diode end-pumped solid-state laser (반도체레이저 단면여기 고체레이저에서의 최적 공진조건에 관한 해석)

  • 김병태;김태석
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.303-307
    • /
    • 1997
  • The energy transfer of a laser-diode-pumped Nd : S-VAP laser was detected by the photoacoustic technique using a PZT detector. The photoacoustic method suggests an effectvie approach to understand the energy transfer mechanism of the laser cavity, and to find out the optimum output coupler of the oscillator with comparative ease.

  • PDF

Introduction to research and current trend about nanopore-based nanobiosensor (나노포어 기반 나노바이어센서 기술)

  • Kim, Joo Hyoung;Youn, Yeoan;Lee, Choongman;Yoo, Kyung-Hwa
    • Vacuum Magazine
    • /
    • v.2 no.1
    • /
    • pp.4-9
    • /
    • 2015
  • A nanopore is a very small hole that can be used as single-molecule detector. The detection principle is based on monitoring the ionic current reduced by passage of a molecule through the nanopore as a voltage is applied across the nanopore. Here, we introduce biological nanopores and solid-state nanopores. Then, research and current trend about nanopore-based DNA biosensor and protein analysis are reviewed.

Nuclear Physics Methods for Determination of Radon in Water

  • Oyunchimeg, Ts.;Norov, N.;Khuukhenkhuu, G.
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.51-53
    • /
    • 2002
  • The results of the measured specific activities of Rn-222 in sewerage and drinking water of Ulaanbaatar City, Mongolia using the HP-Ge gamma-spectrometer, solid state nuclear track detector and liquid scintillator, are compared. The specific radioactivity for the Rn-222 in water of Ulaanbaatar City ranged 10-250 Bk/l, with an average of 110 Bk/l.

  • PDF

Detection of Alpha Tracks of Boron by Nuclear Reaction with Neutron (중성자 핵반응에 의한 보론의 알파트랙 검출)

  • Sohn, Se Chul;Pyo, Hyung Yeal;Park, Yong Jun;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • The detection efficiencies of the several solid track detectors were investigated for the determination of boron content in aqueous solution by using the alpha muti-Radioisotope(RI) source. Polycarbonate (Lexan and CR-39) and cellulose nitrate (CN-85 and LR-115) were selected as materials for alpha track detection of boron. Alpha muti-RI source, uranium metal particles and boron standard solution were used for alpha emission. In this study, four solid track detectors(CN-85, LR-115, Lexan and CR-39) were characterized under various etching conditions as well as neutron irradiation conditions. As a result, the CN-85 was turned out to be best to provide good efficiency among the four detectors. The selected solid track detector was utilized for the determination of trace amount of boron in aqueous sample and its results were discussed in the text.

Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray (감마선을 이용한 단열배관의 실시간 두께측정시스템 개발)

  • Jang, Ji-Hoon;Kim, Byung-Joo;Kim, Gi-Dong;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.500-507
    • /
    • 2002
  • By this study, on-line real-time radiometric system was developed using a 64 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses an Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer through cable. This system collects and analyses the data from the detector array in real-time as the crawler travels over the piping system. The maximum measurable length of pipe is 120cm/min. in the case of 1mm scanning interval.

Development of Dimmable Magnetic Ballast for HID-Lamps by Zero Current Switching on SCRs (SCR의 영전류 스위칭에 의한 HID 램프용 조도제어형 자기식 안정기 개발)

  • Lee, Hyeon-Jin;Yoo, Jae-Woong;Park, Chong-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.9-16
    • /
    • 2010
  • In this paper, we have proposed a new dimmable magnetic ballast for HID(High Intensity Discharge) lamps consisted of AC switches to variate inductance value by using Silicon Controlled Rectifiers and the isolated zero current detector on inductor. Conventional dimming ballast has used relays or Solid State Relays in AC switches. However, a relay is difficult to zero current switching, because it has long operating time(10[ms]), and price competitiveness of SSR is very low. The proposed AC switches are suitable to switch at zero inductor current and it is accurately detected by using a opto-coupler. SCR is cheaper than SSR, and it is suitable to switch at zero inductor current because SCR is automatically turned off under holding current at no gate signal. Operating principles, simulation results and experimental results of the proposed ballast are described.

Transistor에 의한 low noise charge sensitive amplifier

  • 정만영
    • 전기의세계
    • /
    • v.11
    • /
    • pp.8-13
    • /
    • 1963
  • Solid state nuclear radiation detector에 사용되는 transistor에 의한 저잡음 charge sensitive preamplifier의 설계방식과 이에 대한 실측결과에 관하여 기술하였다. 먼저 transistor noise의 제원인을 분석하고 이 잡음들을 최소로 하기 위하여 이에 관련된 각 parameter에 대하여 이론 및 실험적으로 고찰하였다. 지금까지 알려진 진공관식 증폭기의 최소잡음은 등가전자수로 표시하면 약 250전자 정도이고 그 transistor증폭기에 있어서는 약 1,000전자 정도이었으나 본 설계방식에 의하여 제작된 transistor증폭기에서는 detector를 포함한 전 input capacitance가 약 100PF일때 약 400전자의 양호한 저잡음특성을 보이고 있으며 linearity 및 stability도 매우 좋은 결과를 보이고 있다. 여기에 사용된 cascode회로 자체는 이미 오래 전부터 알려져 있었지만 잡음을 최소로 하기 위한 설계방법은 지금껏 알려지지 않고 있으므로 본 논문에서는 전치증복기의 소요이득에서 잡음을 최소로 할 수 있는 설계방식을 확립하여 이 방식에 의한 실측결과는 종래의 transistor를 사용한 것보다 가장 좋았다.

  • PDF

LET Calibration of Fe 500 MeV/u Ions using SSNTD (고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정)

  • KIM, Sunghwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ($\overline{y_D}$) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.

Electrical Properties of Co- and Cu-Doped Nickel Manganite System Thick Films for Infrared Detectors

  • Lee, Dong-Jin;Lee, Sung-Gap;Kim, Kyeong-Min;Kwon, Min-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.261-264
    • /
    • 2017
  • $Ni_{0.79}Co_{0.15-x}Cu_xMn_{2.06}O_4$ ($0{\leq}x{\leq}0.09$) thick films were fabricated using the conventional solid-state reaction method and screen-printing method. Structural and electrical properties of specimens based on the amount of Cu were observed in order to investigate their applicability in the infrared detector. All specimens showed a single spinel phase with a homogeneous cubic structure. As the amount of Cu increased, the average grain size increased and was found to be approximately $5.01{\mu}m$ for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen. The thickness of all specimens was approximately $55{\sim}56{\mu}m$. As Cu content increased, the resistivity and TCR properties at room temperature decreased, and these values for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen were $502{\Omega}-cm$ and $-3.32%/^{\circ}C$, respectively. The responsivity and noise properties decreased with an increase in Cu content, with the specimen with a Cu content of x=0.09 showing 0.0183 V/W and $5.21{\times}10^{-5}V$, respectively.

Application of CR-39 Microfilm for Rapid Discrimination Between Alpha-Particle Sources

  • Dwaikat, Nidal;Al-Karmi, Anan M.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.881-885
    • /
    • 2017
  • This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.