• Title/Summary/Keyword: solid phase method

Search Result 1,185, Processing Time 0.027 seconds

Calculation of the Entropies and Chemical Potentials of Hard-Sphere Solutes Solvated in Hard-Sphere Solids Using the Radial Free-Space Distribution Function

  • 윤병집
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1209-1212
    • /
    • 1999
  • The entropies and chemical potentials of hard-sphere solutes solvated in hard-sphere solids were calculated by Monte Carlo method using the radial free-space distribution function. This method is based on calculating the entropy by comparing the free volume of a molecule with that of an ideal gas, and is applicable even when the size of solute is very large and the solvent is a solid. When the diameter of hard-sphere solute is small the solute molecule behaves as like as a fluid in solid structures, but when the diameter of solute becomes large, a fluid-to-solid phase transition takes place. The fluid-to-solid phase transition occurs at the region of the smaller size of solute with the more increase of solvent density. The least square fit values of analytical form of the radial free-space distribution functions of solute molecules are presented for future uses.

Studies on the development of enzyme linked immuno-sorbent assay (ELISA) for hepatitis B surface antigen (HBsAg) by monoclonal antibodies of different affinity constants

  • Kim, Gye-Won;Hong, Sung-Youl;Shin, Soon-Cheon;Lee, Sung-Hee;Kim, Won-Bae
    • Archives of Pharmacal Research
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 1987
  • Mouse monocolonal antibodies to Hepatitis B surface antien (HBsAg) were prepared and their functional capabilities tested by the method of solid phase enzyme linked immuno sorbent assay (ELISA). HBsAg binding studies inicated that one monoclonal antibody 6E-1-1 bound more HBsAg at a faster rate than the other monoclonal antibodies. Also, for the binding inhibition studies with the selected monoclonal antibody 6E-1-1, one monoclonal antibody 8D-3-6 didn't exhibit binding inhibition for HBsAg. Then, a simultaneous ELISA method was developed for the immunodiagnosis of HBsAg. Different combinations of two monoclonal antibodies as solid phase and horseradish peroxidase (HRPO) labeled phase were studied. The combination of monoclonal antibody of higher affinity constant (6E-1-1) immobilized in a solid phase and monoclonal antibody of lower affinity constant (8D-3-6) as a HRPO laeled phase was more sensitive when two monoclonal antibodies of different affinity constants for HBsAg were prepared.

  • PDF

Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Cigarette Material by Solid Phase Extraction and HPLC

  • Hu, Qun;Yang, Guangyu;Ma, Jing;Liu, Jikai
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.10
    • /
    • pp.1433-1436
    • /
    • 2003
  • A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.

Solid-Phase Refolding of Inclusion Body Protein in Packed Bed Adsorption and Expanded Bed Adsorption Chromatography (Packed Bed Adsorption과 Expanded Bed Adsorption 크로마토그래피를 이용한 내포체 단백질의 고체상 재접힘)

  • 최원찬;김민영;서창우;이은규
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.500-505
    • /
    • 2003
  • ‘LK (lipoprotein kringle) 68’is a polypeptide of a modified ansiostatin consisting of three kringle structures that might be clinically useful as a potential cancer therapeutics. It can be produced by overexpressing it as inclusion body in recombinant E. coli. In this study, solid-phase refolding processes using packed bed adsorption (PBA) and expanded bed adsorption (EBA) column were carried out to compare their refolding yields with that of the conventional, solution-phase refolding process, For the solution-phase and the PBA-mediated processes employing Q-Sepharose, washed inclusion body was used as the starting material, whereas both washed inclusion body and E. coli homogenate were used for the EBA-mediated process employing streamline DEAE. On the final recovery LK68 per unit mass of wet cell basis, the EBA- and PBA-mediated processes showed about 2.7- and 1.5-fold higher yields, respectively, than the solution-phase refolding method. The solid-phase refolded LK68 demonstrated the same Iysine binding bioactivity and the retention time in the RP-and SEC-HPLC as those of the native protein.

Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water (해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치)

  • Cho Ki Woong;Jung Kyungwha;Shin Jongheon;Kim Suk Hyun;Hong Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.34-40
    • /
    • 2000
  • A multisample extraction device was newly designed for efficient extraction of dissolved lipophillic organic compounds from sea water sample. This device allowed extraction of organic compounds from up to 96 sample at a time using 96 multifolder on the principle of solid phase extraction with commercially available octadecyl silane (ODS) cartridges. The recovery yield of the new divice was higher than 90 % while that of conventional liquid-liquid extraction process are only 60 - 70 %. The amount of solvent required for the new device could be reduced to less than 20㎖ per 1ℓ of sample while 1 - 2 ℓ of solvent were used in the conventional liquid-liquid extraction process. The usefulness of this novel method was demonstrated with sea water samples collected from Yellow sea, and the qualitative and quantitative analyses results of the dissolved hydrocarbon showed this method was superior to that of conventional liquid-liquid extraction process in efficiency and reliability.

  • PDF

Analysis and Experiment on Cryogenic Refrigeration Using Solid Nitrogen (고체 질소를 이용한 극저온 냉동의 해석 및 실험)

  • 변정주;이윤숙;장호명
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.77-83
    • /
    • 2001
  • The thermal characteristics of solid nitrogen are investigated by experiment and analysis for the purpose of evaluating its feasibility as a cooling medium for HTS (high T$_{c}$ superconductor) magnets. A cryostat to refrigerate a liquid-nitrogen container well below its freezing temperature with a 2-stage GM cryocooler is designed and constructed. The spatial distribution of temperature is measure as a function of time during the freezing and melting processes. from which the thermal diffusivity of solid nitrogen can be approximately calculated. the freezing process is formulated and solved by the integral method with an assumption of phase equilibrium at the solid-liquid interface and experimental observation. It may be concluded that the thermal diffusion in solid phase is much slower than in liquid and the degree of super-saturation is quite severe in the solidification of nitrogen.n.

  • PDF

Heat Transfer and Solidification in the Inviscid Stagnation Flow (비점성 정체 유동 하에서의 응고와 열전달)

  • Yoo Joo-Sik;Kim Yong-Jin
    • Journal of computational fluids engineering
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • This study investigates the problem of phase change from liquid to solid in the inviscid stagnation flow. The instantaneous location of the solid-liquid interface is fixed for all times by a coordinate transformation. Finite difference method is used to obtain the solution of the unsteady problem, and the growth rate of solid and the transient heat transfer from the surfaces of solid are investigated. The transient solution is dependent on the three dimensionless parameters, but the final steady state is determined by only one parameter of temperature ratio/conductivity ratio. It is observed that the instantaneous heat flux at the surface of solid can be obtained with sufficient accuracy by measuring the thickness of the solid or vice versa.

  • PDF

In Vitro Refolding of Inclusion Body Proteins Directly from E. coli Cell Homogenate in Expanded Bed Adsorption Chromatography (Expanded Bed Adsorption 크로마토그래피를 사용하여 재조합 E. coli 세포 파쇄액으로부터 내포체 단백질을 직접 재접힘하는 공정)

  • 조태훈;서창우;이은규
    • KSBB Journal
    • /
    • v.16 no.2
    • /
    • pp.146-152
    • /
    • 2001
  • To avoid the intrinsic problem of aggregation associated with the traditional solution-phase refolding process, we propose a solid-phase refolding method integrated with expanded bed adsorption chromatography. The model protein used was a fusion protein of recombinant human growth hormone and a glutathione S transferase fragment. It was demonstrated that the EBA-mediated refolding technique could simultaneously remove cellular debris and directly renature the fusion protein inclusion bodies in the cell homogenate with much higher yields and less agregation. To demonstrate the applicability of the method, we successfully tested the three representative types of starting materials, i. e., rhGH monomer, washed inclusion bodies, and the E. coli homogenate. This direct and simplified refolding process could also reduce the number of renaturation steps required and allow refolding at a higher concentration, at approximately 2 mg fusion protein per ml of resin. To the best of our knowledge, it is the first approach that has combined the solid-phase refolding method with expanded bed chromatography.

  • PDF

Determination of Acaricides in Honey by Solid-Phase Extraction and Gas Chromatography / Mass Spectrometry

  • Hong, Joo-Yeon;Jung, Ok-Sang;Ryoo, Jae-Jeong;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • An analytical method based on solid-phase extraction and gas chromatography / mass spectrometry has been developed for measurement of acaricides (amitraz, bromopropylate, coumaphos, cymiazole, and tetradifon) in honey sample. In the stability test of acaricides in honey, amitraz underwent a rapid degradation into 2,4-dimethylaniline (DMA), 2,4-dimethylphenylformamide (DMPF), and N-(2,4-dimethylphenyl)-N'-methylformamidine (DMPMF), whileas other acaricides were found to be stable even for over three months. Extraction of five acaricides from 5g of honey sample was carried out by liquid-liquid extraction using 20mL of ethylacetate. For purification, Florisil-SPE cartridge with elution of 5mL of n-hexane/ acetone (55:45, v/v) was found to remove interferences effectively. Quantification was performed using gas chromatography / mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery values from honey spiked at 0.02 and 0.20 ${\mu}g/g$ levels, respectively, were found to be greater than 75% for all acaricides. The method detection limits for acaricides were ranged from 0.1 to 3 ppb. The developed method in this study was applied for the monitoring of acaricides in honey products collected from urban markets in Korea.

Sampling Methods for Quantification of Solid-state Phases in Powder Samples with Solid-state NMR Spectroscopy

  • Han, Oc-Hee;Kim, Sun-Ha;Ko, Tae-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1077-1079
    • /
    • 2009
  • To minimize the variance in the quantification of solid-state phases in powder samples, gently placing polycrystalline samples one next to another directly in a sample holder is better than trying to mix them homogeneously prior to transferring to a sample holder. However, the solid-state cross polarization-magic angle spinning (CP-MAS) nuclear magnetic resonance (NMR) spectroscopy results demonstrated that it is essential in this sampling method to place all the samples in the location of consistent signal sensitivity. The same sampling method may be employed in other spectroscopic quantification techniques of solid-state phases if the method to limit the sample to the location with uniform signal sensitivity in the sample holder is adapted to each technique.