• 제목/요약/키워드: solid earth

검색결과 227건 처리시간 0.037초

Measurement of Evaporation Rates for Lanthanum and Neodymium Chlorides

  • Kwon, S.W.;Lee, Y.S.;Jung, J.H.;Chang, J.H.;Kim, S.H.;Lee, S.J.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2017년도 추계학술논문요약집
    • /
    • pp.74-74
    • /
    • 2017
  • Electrorefining is a key step in pyroprocessing. The electrorefining process is generally composed of two recovery steps - the deposit of uranium onto a solid cathode and the recovery of the remaining uranium and TRU elements simultaneously by a liquid cadmium cathode. Uranium deposit recovered from the solid cathode is a dendritic powder. It is necessary to separate the adhered salt from the deposits prior to the consolidation of uranium deposit. The adhered salt is composed of lithium, potassium, uranium, and rare earth chlorides. Distillation process was employed for the cathode processing. One of the operation methods is distillation of the salt at low temperature ($900^{\circ}C$), and then melting of the deposit at high temperature to avoid a backward reaction. For the development of the salt distiller, the distillation behavior of the low vapor pressure chlorides should be studied. Rare earth chlorides in the adhered salt of uranium deposits have relatively low vapor pressures compared to the process salt (LiCl-KCl). In this study, the evaporation rates of the lanthanum and neodymium chlorides were measured for the salt separation from electrorefiner uranium deposits in the temperature range of $825{\sim}910^{\circ}C$. The evaporation rate of both chlorides increased with an increasing templerature. The evaporation rate of lanthanum chloride varied from 0.12 to $1.68g/cm^2/h$. Neodymium chloride was more volatile than lanthanum chloride. The evaporation rate of neodymium chloride varied from 0.20 to $4.55g/cm^2/h$. The evaporation rate of both chlorides are more than $1g/cm^2/h$ at $900^{\circ}C$. Even though the evaporation rates of both chlorides were less than that of the process salt, the contents of the lanthanide chlorides were small in the adhered salt. Therefore it can be concluded that $900^{\circ}C$ is suitable for the operation temperature of the salt distiller.

  • PDF

비점오염 부하 저감을 위한 식생 매트의 수질정화능 평가 (Assessment of Water Purification Capacity of Vegetation Mats for the Reduction of Nonpoint-Source Pollution Loads)

  • 송규성;한상훈
    • Ecology and Resilient Infrastructure
    • /
    • 제3권1호
    • /
    • pp.70-75
    • /
    • 2016
  • 본 연구의 목적은 하천과 호소로 유입되는 비점오염을 저감하기 위해 자연형 하천조성기술 중에서 활용성이 증가되고 있는 식생 매트에 충진재를 적용하여 수질정화기능을 향상하는데 있다. 본 연구에서는 우수한 충진재 선별을 위하여 제올라이트, 규조토 그리고 이들을 혼합하여 소성한 발포여재에 대한 수질정화기능 실내 평가실험과 제방사면조건에서 강우 유출수를 대상으로 한 식생 매트의 수질정화능 검증 현장실험을 진행하였다. 충진재별 수질정화기능은 발포여재가 SS 46.3%, T-N 29.9%, T-P 33.3%로서 다른 충진재보다 수질정화기능이 우수하였다. 식생 매트의 현장 실험에서는 수질정화능은 SS가 60.1%, T-N이 32.2%, T-P가 20.2%으로서 식생 매트의 우수한 오염저감 능력을 확인할 수 있었다.

하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향 (Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants)

  • 이태환;박민혜;이보미;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

열차폐용 희토류 산화물의 상형성과 열물성 (Phase Evolution and Thermo-physical Properties of Rare-earth Oxides for Thermal Barrier Systems)

  • 심병철;곽길호;이성민;오윤석;김형태;장병국;김성원
    • 한국분말재료학회지
    • /
    • 제17권2호
    • /
    • pp.148-153
    • /
    • 2010
  • Thermal barrier systems have been widely investigated over the past decades, in order to enhance reliability and efficiency of gas turbines at higher temperatures. Yttria-stabilized zirconia (YSZ) is one of the most leading materials as the thermal barriers due to its low thermal conductivity, thermodynamic stability, and thermal compatibility with metal substrates. In this work, rare-earth oxides with pyrochlore phases for thermal barrier systems were investigated. Pyrochlore phases were successfully formed via solid-state reactions started from rare-earth oxide powders. For the heat-treated samples, thermo-physical properties were examined. These rare-oxide oxides showed thermal expansion of $9{\sim}12{\times}10^{-6}/K$ and thermal conductivity of 1.2~2.4 W/mK, which is comparable with the thermal properties of YSZ.

난지도 매립지 및 그 주변의 지질환경 연구: 중력 및 자력탐사 (Studies on the Geological Environment of the Nanjido Waste Disposal Site: Gravity and Magnetic Investigations)

  • 권병두;김차섭;정호준;오석훈
    • 자원환경지질
    • /
    • 제28권5호
    • /
    • pp.469-480
    • /
    • 1995
  • Gravity and magnetic surveys were carried out to investigate the three-dimensional configuration and characteristics of the landfills at Nanjido waste disposal site. For terrain correction and three-dimensional density inversion of gravity data an algorithm, which calculates the gravity effect of a three-dimensional body by using the solid angle method, is developed. This algorithm has been proved to give more accurate terrain correction values for the small survey area having varied topography like Nanjido site as compared with widely used methods such as Hammer's method and multiquadric equation method. Density inversion of gravity anomaly data gives very useful information about the lateral and vertical variation of the landfills, which can be used to discriminate the kinds of wastes. The average density of filled materials appears to be $1.7\;g/cm^3$ which is much higher than the value $(0.8\;g/cm^3)$ estimated by Seoul City. The lateral variation of density shows high correlation with the pattern of ongoing depression of the landfills. The northern region of the landfill no. 1, which shows low density and high depression, is closely associated with the industrial waste and sludge filled area. The magnetic anomaly data provide information about relative concentration of magnetic materials, which is also very useful to investigate characteristics of the fills. Several high positive anomaly regions on the reduced-to-pole magnetic anomaly map are appeared to be associated with the industrial waste fills, but certain industrial waste fills show low negative anomalies. This kind of magnetic information can be used in selecting drilling locations over landfills away from buried metal products during the stabilization process.

  • PDF

하부 백악기 진주층에서 산출되는 고열역청(pyrobitumen)의 산상 (Occurrence of Pyrobitumen in the Lower Cretaceous Jinju Formation, Korea)

  • 최태진;임현수;이재일;이용일
    • 한국지구과학회지
    • /
    • 제43권5호
    • /
    • pp.639-646
    • /
    • 2022
  • 경상분지 신동층군의 백악기 진주층 일부 사암에서 산출되는 흑색의 불투명 탄화수소인 고열역청(pyrobitumen)의 산상을 처음으로 보고한다. 고열역청은 녹니석 공극벽 선충진(pore-lining) 교결물을 피복하거나 교결물 끝부분에 스며들어간 상태로 산출되므로, 녹니석 교결물 침전 이후에 생성된 것이며, 이는 과거 원유가 존재했음을 지시한다. 액상의 탄화수소는 진주층이 상당한 깊이로 매몰되는 동안 유입되었으며, 진주층 사암은 저류암의 역할을 했던 것으로 보인다. 진주층에 고열역청이 존재하는 것은 진주층이 액상 탄화수소의 이동 이후 심부 매몰과정을 겪었음을 지시한다. 그 후 매몰 온도가 더 증가하면서 탄화수소의 열분해가 일어나고 고열역청이 저류암에 잔류물로 남게 되었다.

A Spectroscopic Study on Singlet Oxygen Production from Different Reaction Paths Using Solid Inorganic Peroxides as Starting Materials

  • Li, Qingwei;Chen, Fang;Zhao, Weili;Xu, Mingxiu;Fang, Benjie;Zhang, Yuelong;Duo, Liping;Jin, Yuqi;Sang, Fengting
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권10호
    • /
    • pp.1656-1660
    • /
    • 2007
  • Using solid inorganic peroxides (including Li2O2, Na2O2, SrO2 and BaO2) as starting materials, three reaction paths for singlet oxygen (1O2) production were developed and studied. Their 1O2 emission spectra in the near- IR region and visible region from these reaction paths were simultaneously recorded by a near-IR sensitive Optical Multichannel Analyzer and a visible sensitive Optical Spectrum Analyzer, respectively. The comparison of their 1O2 emission spectra indicated that: (1) in term of the efficiency for 1O2 production, the gasliquid- solid reaction path (in which Cl2 or HCl and H2O reacted with the solid inorganic peroxides suspension in CCl4) was prior to the gas-solid reaction path (in which Cl2 or HCl reacted with the solid inorganic peroxides suspension in CCl4), but was inferior to the gas-liquid reaction path (in which Cl2 or HCl reacted with the solid inorganic peroxides solution in H2O or D2O); (2) the alkali metal peroxides (such as Li2O2 and Na2O2) was prior to the alkaline earth metal peroxides (such as SrO2 and BaO2) as the solid reactants, and Cl2 was favorable than HCl as the gas reactant in efficiency for 1O2 production in these reaction paths.

박테리아 발광 특성을 이용한 고형시료 급성 독성법 연구 및 적용 (Development and Application of Acute Bioassay Method on Solid Samples using Bioluminescence Producing Bacteria)

  • 고경석;공인철;정홍경;노열
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제12권6호
    • /
    • pp.46-52
    • /
    • 2007
  • 생물 발광 생산 균주, Escherichia coli DH5 RB1436를 이용하여 고형환경 시료에 대한 독성 방법을 개발하고 적용하였다. 토양과 균주의 비율은 1 : 4(w/v) 정도가 적절하였으며, 측정 방법의 간편성을 고려하여 가열 감량된 토양 첨가군 대신에 동일한 부피의 인산염 완충액 첨가군을 고형시료 독성의 대조군으로 정하였다. 토양측정망 시료중 대체적으로 오염원 농도가 상대적으로 높은 그룹과 낮은 그룹의 독성은 각 43과 26%로 뚜렷한 차이를 나타내었다. 토양 그룹들의 $EC_{50}$는 범위가 $1.8{\sim}4.6\;g$으로 조사된 반면에, 댐저수지 퇴적물과 매립물들은 모두 0.22 g 보다 낮게 조사되었다. 상이한 고형환경 시료에 대해 뚜렷한 독성 차이를 나타낸 본 생물검정법은 다양한 환경 시료의 독성을 평가하는 유용한 방법으로 사용할 수 있을 것이다.

헤드스페이스-SPME 방법을 이용한 트리메틸아민의 분석방법 연구 (The Analysis of Airborne Trimethylamine Using a Headspace (HS)-SPME Method)

  • 안지원;김기현
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.357-366
    • /
    • 2008
  • In this study, the analytical performance of trimethylamine (TMA) were investigated with respect to headspace-solid phase microextraction (HS-SPME) method. In order to induce the elution of aqueous TMA to headspace, NaOH was added as a decomposition reagent to aqueous TMA standard. By controlling the combination of three major variables for TMA extraction, the extent of extraction was compared between the two contrasting conditions for each variable (i.e., reaction time (long (L) vs short (S)), exposure temperature (30 vs $50^{\circ}C$), and exposure time (10 vs 30 min)). The results of this comparative analysis showed that the extraction efficiency for all eight types of HS-SPME combinations decreased on the order: L-30-30>L-50-10>L-30-10>L-50-30>S-30-30>S-50-30>S-50-10>S-30-10. The effect of reaction time appeared to exert significant influences on the relative recovery rate of HS-SPME at 90% confidence level. However, the effects of exposure temperature or exposure time were not so significant as reaction time. When the recovery rate of HS-SPME is compared against the direct injection of liquid standard into GC injector, it recorded as 2%. According to this comparative study, the reaction conditions for HS-SPME application can exert significant influences on the analysis of TMA.

소형 지구 관측 위성용 플래시 기반 저장장치 설계 및 시험 (Design and Test Flash-based Storage for Small Earth Observation Satellites)

  • 백인철;박형식;황기선
    • 대한임베디드공학회논문지
    • /
    • 제13권5호
    • /
    • pp.253-259
    • /
    • 2018
  • Recently, small satellite industries are rapidly changing. Demand for high performance small satellites is increasing with the expansion of Earth Observation Satellite market. A next-generation small satellites require a higher resolution image storage capacity than before. However, there is a problem that the HW configuration of the existing small satellite image storage device could not meet these requirements. The conventional data storing system uses SDRAM to store image data taken from satellites. When SDRAM is used in small satellite platform of a next generation, there is a problem that the cost of physical space is eight times higher and satellite price is two times higher than NAND Flash. Using the same satellite hardware configuration for next-generation satellites will increase the satellite volume to meet hardware requirements. Additional cost is required for structural design, environmental testing, and satellite launch due to increasing volume. Therefore, in order to construct a low-cost, high-efficiency system. This paper shows a next-generation solid state recorder unit (SSRU) using MRAM and NAND Flash instead of SDRAM. As a result of this research, next generation small satellite retain a storage size and weight and improves the data storage space by 15 times and the storage speed by 4.5 times compare to conventional design. Also reduced energy consumption by 96% compared to SDRAM based storage devices.