• Title/Summary/Keyword: solenoid magnet

Search Result 74, Processing Time 0.046 seconds

A Study on the Design of Magnetic Circuit for MgO ion plating Device (MgO 박막장치의 자기회로 설계에 관한 연구)

  • Jeong, Y.H.;Choi, Y.W.;Kang, D.H.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.723-725
    • /
    • 2001
  • Ion plating method using plasma is faster as several times than electron beam plating method in plating process. Recently, a variety of techniques for this method are being researched. In this paper to produce sheet plasma with high density for ion plating we designed magnetic circuit of MgO plating device consisting of solenoid coil, rectangular permanent magnet. And, we researched on the effect of those by analyzing magnetic field distribution using FEM.

  • PDF

A study on the fundamental characteristics of Giant Magnetostirictive Alloy, Terfenol-D (초자기변형합금 Terfenol-D의 기초특성에 관한 연구)

  • Baek, Chang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.186-188
    • /
    • 1994
  • Fundamental characteristics of Giant Magnetostrictive Alloy Terfenol-D$(Tb_{0.3}Dy_{0.7}Fe_{1.9\sim1.95})$ were measured by experiments. Magnetostrictions of Terfenol-D samples whose lengths are 15 and 25 mm have been measured under compressive stress from 0 to 14 MPa, when the applied magnetic field was up to 1200 Oe. The relationship between magnetostriction and field is shown graphically in the form of $H-{\lambda}$, curve. For the experiment, solenoid magnet and lever-arm-type stress equipment were designed and fabricated. The magnetostriction is measured by laser displacement measuring system and the stress applied to the sample is measured by load cell.

  • PDF

Study on the test results of ITER CS superconducting magnet power supply (ITER CS 초전도 코일 전원장치 시험 결과에 대한 고찰)

  • Song, Inho;Choi, Jungwan;Seo, Jae Hak;Shin, Hyun Kook;Oh, Jong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.130-131
    • /
    • 2019
  • 국제 핵융합실험로(ITER)를 위해 한국이 제작, 시험, 설치 및 시운전을 하기로 되어 있는 CS(Central Solenoid) 초전도 자석용 전원장치의 시험 및 그 결과에 관하여 논의하고자 한다. 토카막 운전에서 플라즈마 발생 및 제어를 위한 대전류, 고전압, 270 kA 단락 용량 및 4상한 운전 특성을 갖는 45 kA/1050 V의 12펄스 싸이리스터 AC/DC 컨버터 및 제어기를 제작완료하였으며, ITER 부지로 운송하기 전에 공장의 전원 및 부하용량을 고려하여 시험절차서를 개발하였으며, 공장시험(FAT, Factory Acceptance Test)를 진행하였다.

  • PDF

Critical current characteristic of solenoid magnet with anisotropic HTS tapes (비등방성을 고려한 고온초전도 솔레노이드 마그네트의 임계 전류 특성)

  • Kang, Joon-Sun;Nah, Wan-Soo;Kwon, Young-Kil;Sohn, Myoung-Hwan;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.966-968
    • /
    • 2000
  • 비등방성 고온 초전도 테이프는 자장의 세기뿐만 아니라 방향에 따라서도 임계 전류 값이 영향을 받는다. 이러한 비등방성 고온 초전도 테이프로 권선된 솔레노이드 마그네트의 임계 전류 특성 및 임계 전류를 결정짓는 위치를 알아내기 위해, 솔레노이드 모델의 자장 분포 및 수직 자장 성분과 평행 자장 성분을 구하고 임계 전류는 비선형 방정식을 수치적인 방법을 이용하여 예측해보았다.

  • PDF

Controls on KSTAR Superconducting Poloidal Field (PF) Magnets

  • Hahn, Sang-Hee;Kim, K.H.;Choi, J.H.;Ahn, H.S.;Lee, D.K.;Park, K.R.;Eidietis, N.W.;Leuer, J.A.;Walker, M.L.;Yang, H.L.;Kim, W.C.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.23-28
    • /
    • 2008
  • As a part of the plasma control system (PCS) for the first plasma campaign of KSTAR, seven sets of fast feedback control loop for the superconducting poloidal field magnet power supply (PF MPS) have been implemented. A special real-time digital communication interface has been developed for the simultaneous exchanges of the current/voltage data from the 7 sets of 12-thyristor power supplies in a 200 microsecond control cycle. Preliminary power supply tests have been performed before actual cooldown of the device. A $29mH/50m{\Omega}$ solenoid dummy has been fabricated for a series of single power supply tests. Connectivity and response speed of the plasma control system have been verified. By changing hardware cabling, this load was also used to estimate mutual inductance coupling effects of two geometrically adjacent solenoid coils on each power supply. After the cooldown was complete, each pair of the up/down symmetric PF coils has been serially connected and tested as part of the device commissioning process. Bipolar operation and longer pulse attempts have been investigated. The responses of the coils and power supplies corresponding to the plasma magnetic controls in plasma discharges are also analyzed for the future upgrades.

Recent development of high gradient superconducting magnetic separator for kaolin in china

  • Zhu, Zian;Wang, Meifen;Ning, Feipeng;Yang, Huan;Li, Peiyong;Zhang, Yiting;Wang, Zhaolian;Zhang, Guoqing;Hou, Zhilong;Liu, Zhongxiu;Dai, Zhong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.5-8
    • /
    • 2017
  • A series of high gradient superconducting magnetic separator (HGMS) for kaolin has been developed. It is used for processing kaolin to increase the brightness or whiteness whether it is for paper or ceramic applications. The HGMS system mainly consists of a solenoid magnet with a zero boil-off helium cryostat, a double reciprocating canisters system, and a PLC (Process Logic Controller) fully automatic control system based on SCADA (Supervisory Control and Data Acquisition) system. We have successfully developed CGC-5.5/300 and CGC-5.0/500 HGMS systems in the recent years, and now three sets of them are on-site operation in different customers. This paper will present recent progress of the HGMS system, the results of some experiments on processing kaolin clay used HGMS, and the on-site operation.

A Haptic Navigation System for Visually Impaired Persons (시각장애인을 위한 햅틱 네비게이션 시스템)

  • Kim, Sang-Youn;Cho, Seong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.133-143
    • /
    • 2011
  • This paper proposes a mobile navigation system which haptically presents the way to go to visually impaired persons. In order to convey the tactile information to the visually impaired persons, we develop a new tactile module with a solenoid, a permanent magnet and an elastic spring. Furthermore, we suggest 2D vibration flow which originates from one point and gradually propagates to other points on a surface of the haptic navigation system. The tactile module and the vibration flow method are incorporated into the proposed haptic navigation system and they stimulate the user's finger pad and palm, respectively. We conduct experiments to investigate that the proposed navigation system haptically provides the direction to the users. From the experimental results, we verify that the proposed system can generate enough tactile sensation to guide the direction to go in real-time.

Design and Control of 3 D.O.F. Spherical Actuator Using the Magnetic Force of the Electromagnets (전자석의 자기력 제어를 이용한 구형 3 자유도 액추에이터의 설계 및 제어)

  • Baek, Yun-Su;Yang, Chang-Il;Park, Jun-Hyeok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1341-1349
    • /
    • 2001
  • In this paper, 3 D.O.F. actuator, which has three degrees of freedom in one joint, is proposed. The proposed 3 D.O.F. spherical actuator is composed of the rotor and atator. The upper plate of the stator supports the rotor and five electromagnets are located at the base of the stator. The rotor has two permanent magnets, and each rotational axis of the rotor gimbal system is supported by the bearing. To find out the governing equations for the torque generation, Coulombs law and Lorentz force with respect to magnetism is applied. As the experimental results, if the distance between electromagnet and permanent maget is far enough, the force between these magnets can be expressed from current of coils and z-axial distance. For the purpose of control 3 D.O.F. actuator, PID control law is applied. The experimental results are presented to show the validity of the proposed 3 D.O.F. actuator.

Insulation of Winding and Current Lead of the High-Tc Superconducting Magnets for DC Reactor Type SFCL (DC 리액터형 고온초전도한류기용 고온초전도자석의 권선 및 전류리드의 절연)

  • 양성은;배덕권;전우용;김영식;김상현;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.226-229
    • /
    • 2003
  • Following the successful development of practical high temperature superconducting (HTS) wires, there has been renewed activity in the development of superconducting power equipments. HTS equipments must be operated in the coolant, such as liquid nitrogen (L$N_2$) or cooled by cooler, such as GM-cryocooler to maintain the temperature below critical temperature. In this paper, dielectric strength of some insulating materials, such as epoxy, teflon, and glass fiber reinforced plastic (GFRP) in L$N_2$was measured. Surface breakdown voltage of GFRP which is basic property in design of HTS solenoid coil was measured. Epoxy is a goof insulating material but it is fragile at cryogenic temperature. The multi-layer insulating method of current lead is suggested to compensate this fragile property. It consists of teflon tape layer and epoxy layer fixed with texture. Based on these measurements, the 6.6㎸ class HTS magnet for DC reactor type high-T$_{c}$ superconducting fault current limiter (SFCL) was successfully fabricated and tested.d.

  • PDF

Development of a Noncontacting 6 DOF Micro-Postioner Driven by Magnetic Force-Design, Modeling and Control- (자기력을 이용한 비접촉 6자유도 미소위치결정 기구의 개발-설계, 모델링 및 제어-)

  • Choi, Kee-Bong;Park, Kyi-Hwan;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1164-1176
    • /
    • 1996
  • A magnetically levitated micro-positioner is implemented to avoid mechanical friction and increase precision. Since magnetic levitation system is inherently unstable, most concern is focused on a magnetic circuit design to increase the system dynamic stability. For this, the proposed levitation system is constructed by using an antagonistic structure which permits a simple design and robust stability. From the dynamic equations of motion, it is verified that the proposed magnetically levitated system is decoupled in 6 degree-of-freedom motion. Experimental results are presented in terms of time response and accuracy.