• 제목/요약/키워드: solar space heating

검색결과 131건 처리시간 0.027초

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

Statistical Analysis of Supersonic Downflows in Sunspot Penumbrae

  • Kim, Hyunnam;Solanki, Sami K.;Lagg, Andreas;Kim, Kap-Sung
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.75.1-75.1
    • /
    • 2014
  • Sunspot penumbrae show supersonic downflow patches along the periphery. These patches are believed to be the return channels of the Evershed flow. There was previous study to investigate their structure in detail using Hinode SOT/SP observations (M. van Noort et al. 2013) but their data sample was only two sunspots. To make general description it needs to check more sunspot sample. We selected 242 downflow patches of 17 sunspots using Hinode SOT/SP observations from 2006 to 2012. Height-dependent maps of atmospheric parameters of these downflows was produced by using HeLix which was height dependent LTE inversion code of Stokes profiles. The inversion code at high resolution allows for the accurate determination of small scale structures. The recovered atmospheric structure of three layers indicates that regions with very high downflow velocities contain very strong magnetic fields reaching up to 7kG. The higher downflow velocity patches have bigger patch size. Magnetic fields of downflow patches are more vertical while penumbra shows horizontal field and neighbor of downflow patches have opposite polarity. Temperature of downflow patches at highest layer have more strong value than penumbra at deepest layer. The direction of velocity of downflow patches at highest layer have two branches. These result shows that we can expect some heating precess in the middle of layer.

  • PDF

기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구 (A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion)

  • 이관호;김남규;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구 (Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System)

  • 홍부표;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

생활공간 냉난방용 열펌프의 성능개선을 위한 새로운 혼합냉매(RM-1) 개발 (Development of a New Refrigerant Mixture (RM-1) to improve the performance of Heat Pump System for Heating and Cooling of the Living Space)

  • 송헌;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.67-76
    • /
    • 2011
  • 생활공간 냉난방용 열펌프의 성능향상을 위해 R22의 대체 냉매로서 새로운 혼합냉매R22/R23/R152a(RM-1)을 개발하고 U. S. A.의 NIST사의 REFPRO Pprogram을 이용해 이 혼합냉매의 P-h diagram을 구성하여 실용화에 이용할 수 있도록 하였다. 본 연구는 실험을 통해 R22와 RM-1의 열펌프 성능효과를 분석하였다. 입 출구 물의 온도와 제2의 전열매체로서 물의 질량유량, 압축기의 소요 에너지 그리고 열펌프의 기타 열적 특성을 다양한 조건하에서 측정하였다. 이 실험 데이터를 통해 공기-물 열펌프 시스템에서의 RM-1과 R22의 성능계수(COP)를 비교하였다. 이를 통해, 혼합냉매 RM-1을 사용하는 열펌프 시스템은 외기온 $-17^{\circ}C$에서도 2.2의 성능계수로 작동하는 결과를 본 연구에서 보여주었다.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

정지궤도 위성의 열평형 시험 모델링 및 예비 예측 (THERMAL BALANCE MODELLING AND PREDICTION FOR A GEOSTATIONARY SATELLITE)

  • 전형열;김정훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.142-147
    • /
    • 2009
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be tested under vacuum condition and very low temperature in order to verify thermal design of COMS. The test will be performed by using KARI large thermal vacuum chamber, which was developed by KARI, and the COMS will be the first flight satellite tested in this chamber. The purposes of thermal balance test are to correlate analytical model used for design evaluation and predicting temperatures, and to verify and adjust thermal control concept. KARI has plan to use heating plates to simulate space hot condition especially for radiator panels such as north and south panels. They will be controlled from 90K to 273K by circulating GN2 and LN2 alternatively according to the test phases, while the shroud of the vacuum chamber will be under constant temperature, 90K, during all thermal balance test. This paper presents thermal modelling including test chamber, heating plates and the satellite without solar array wing and Ka-band reflectors and discusses temperature prediction during thermal balance test.

  • PDF

고위도 하부 열권 바람의 소용돌이도와 발산 분석: 행성간 자기장(IMF)에 대한 의존도 (Analysis of Wind Vorticity and Divergence in the High-latitude Lower Thermosphere: Dependence on the Interplanetary Magnetic Field (IMF))

  • 곽영실;이재진;안병호;황정아;김관혁;조경석
    • Journal of Astronomy and Space Sciences
    • /
    • 제25권4호
    • /
    • pp.405-414
    • /
    • 2008
  • 이 연구에서는 고위도 하부 열권 역학을 좌우하는 물리적 과정을 이해하기 위하여, 상이한 행성간 자기장(Interplanetary Magnetic Field, IMF)에 따른 남반구 고위도 하부 열권에서의 소용돌이도(vorticity)와 발산(divergence)을 분석하였다. 이 연구를 위하여 미국립대기연구소(National Center for Atmospheric Research, NCAR)의 열권-이온권 전기역학적 대순환 모델(Thermo sphere-Ionosphere Electrodynamic General Circulation Model, TIEGCM)을 이용하였다. 소용돌이도와 발산 분석은 전체 수평 바람장을 최종적으로 결정하는 운동량원(momentum source)을 밝히는데 도움을 주는 근원적인 흐름을 파악할 수 있게 해주며, 운동량원들의 상대적인 강도를 분석해내는데 좋은 도구가 된다. 고위도 하부 열권의 평균 바람장은 태양 복사와 쥴가열에 의해 유발되는 발산운동 보다는 이온대류에 의해 유발되는 회전운동에 의해 주로 지배된다는 것이 확인되었다. $IMF{\neq}0$와 IMF=0인 경우의 고위도 열권 하부에서의 소용돌이도 차이(difference vorticity)가 모든 IMF 조건에서 발산장 차이(difference divergence)에 비해 훨씬 더 크게 나타났다. 이는 IMF가 발산적인 흐름보다 회전적인 흐름에 더 강하게 영향을 끼치며, 나아가 IMF가 발산운동을 유발하는 에너지 유입보다는 회전운동을 유발하는 운동량 유입에 더 강하게 영향을 끼침을 의미한다. IMF의 방향에 따라 고위도 하부 열권에서의 소용돌이도 차이의 양상이 매우 달랐다 $B_y$가 음일 때는 지자기 위도 $-70^{\circ}$ 이상의 고위도에서 극을 중심으로 양의 소용돌이도 차이가 나타나고 $B_y$가 양일 때는 음의 소용돌이도 차이가 나타났다. $B_z$가 음인 경우 소용돌이도 차이가 저녁 영역에는 양이고 새벽 영역에는 음이며, $B_z$가 양인 경우에는 반대의 분포를 보였다. $B_z$가 음일 때가 양일 때보다 소용돌이도 차이가 더 큰 것으로 확인되었는데, 이는 IMF $B_z$가 남쪽으로 향할 때가 북쪽으로 향할 때보다 고위도 이온권의 이온대류를 더 강화시켜 열권 중성대기의 회전적인 흐름을 더 강하게 유발시킴을 의미한다.

철도차량의 국제 기후환경 시험규격의 수행방안 연구 (Study on the International Climatic Testing Standard for Passenger Car)

  • 윤영관;조영민;최진식;정우성;권순박;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

도시계획단계의 에너지 수요예측 방안에 관한 연구 (A Study on Urban Energy Consumption Estimation on the Urban Planning Stage)

  • 여인애;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2012
  • This study suggested an improved algorithm of urban energy consumption estimation on the urban planning stage which concerns calculation accuracy. The results are as follows. (1) Urban energy consumption was estimated and managed per unit space using E-GIS DB which contains facility information per mesh. (2) Urban energy consumption was reflected by the urban facility classified and standardized by the characteristics of energy use. (3) Calculation accuracy of energy consumption was approached by separately suggested as summer algorithm reflecting urban heat island on summer energy use and winter algorithm reflecting heating system normally used in Korea.

  • PDF