• Title/Summary/Keyword: solar heat collector

Search Result 253, Processing Time 0.025 seconds

A Study on the Collector Characteristics of Evacuated Double Glass Tube by Artificial Sun (인공태양에 의한 이중 진공 유리관의 집열특성에 관한 연구)

  • Nam, Yong-Han;Shin, Jae-Ho;Mo, Joung-Gun;Chung, Han-Shik;Jeong, Hyo-Min;Suh, Jeong-Se
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1542-1547
    • /
    • 2003
  • This paper represents the solar collector performance with type of an evacuate double glass, and a copper tube was installed in center of collector to get a solar thermal energy. The one module of solar collector and artificial sun were used in this experiment The distance between artificial sun and solar collector was fixed at 0.5m, and this experimental condition was focused on winter season. The experiments were carried out. three times for getting a accurate data and the heat amount of one module evacuate d solar collector was estimated at out. 48 kcal/hr.

  • PDF

Simulation of Solar and Ambient-air-assisted Heat Pump (태양열 및 외기 열원식 히트펌프 시스템 시뮬레이션)

  • Baeck, N.C.;Park, J.U.;Song, B.H.;Lee, J.K.;Kim, H.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.17-24
    • /
    • 2000
  • Thermal performance of a SAAHPS (Solar and Ambient-air-assisted Heat Pump System) located in KIER is simulated with TRNSYS 14.2. The SAAHPS is composed of dual evaorators, each of which is used as a solar fluid heat source and an air fluid heat source. Polynomial coefficients data for the SAAHPS is supplied with Frigosoft, a program widely used for heat pump modeling. In general, collector area and storage volume are 2 key parameters in SAAHPS thermal performance. A parametric study is performed in this study to assess sensitivity of collector area and storage volume in SAAHPS. We concluded that firstly collector area and storage volume are the primary variables in SAAHPS thermal performance, secondly COP of SAAHPS is higher than that of conventional heat pumps. Therefore. collector efficiency can be enhanced swith SAAHPS during a heating season.

  • PDF

Simulation Study on the Performance Characteristics in the Solar Hybrid R744 Heat Pump for Residential Applications (주거용 태양열 하이브리드 이산화탄소 열펌프 시스템의 성능특성에 관한 해석적 연구)

  • Kim, Won-Seok;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.678-686
    • /
    • 2011
  • Simulation study on the operating characteristics in the solar hybrid R744 heat pump system for residential applications was carried out with heat pump operating temperature, outdoor temperature and solar radiation. As a result, collector operating time is decreased by 1.5 hours due to the increase of water temperature in the heat storage tank when the heat pump operating temperature rises. Heat pump operating time is reduced by 19.4% owing to the high temperature of a heat storage tank. Besides, indoor heating time is decreased from 10.3 to 5.5 hours as the indoor temperature increases from $3^{\circ}C$ to $11^{\circ}C$. In addition to, when the solar radiation rises from 10 to 20 MJ/$m^2$, the maximum outlet temperature of a solar collector is increased from $65^{\circ}C$ to $71^{\circ}C$.

Theoretical Investigation on the Efficiency of Nanofluid-based Flat-Plate Solar Collector (나노유체 기반 평판형 태양열 집열기의 효율에 관한 이론적인 연구)

  • Lee, Seung-Hyun;Kim, Hyun-Jin;Jang, Seok-Pil
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.188-193
    • /
    • 2012
  • Recently, the nanofluid which is stably dispersing or suspending of nanoparticles in the conventional heat transfer fluids (HTF) such as water and ethylene glycol has attracted significant interests as a solar thermal energy absorbing medium because they have excellent absorption and thermophysical properties compared to the typical HTF. In the present study, the efficiency of nanofluid-based flat-plate solar collector is analytically evaluated using the theoretical model of energy balance equation. The theoretical model considers the incoming solar radiation as a volumetric heat generation and the water-based single wall carbon nanohorn(SWCNH) nanofluid is used as a solar energy absorbing medium. Finally, the efficiency of nanofluid-based collector is calculated according to the volume fraction of SWCNH using the analytical solution.

  • PDF

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

Exergy Analysis of Solar Collector

  • 이석건;이현우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.74-79
    • /
    • 1990
  • Important factors in evaluating solar collcetor efficiency are solar radiation, temperature and flow rate of the working fluid. The effects of these factors on the energy and the exergy gained by water, the working fluid, from the collector were analyzed. The results indicated that the collector efficiency and the energy and the exergy gained by the water from the collcetor increased with the increase of solar radiation. According to the exergy analysis, as the water temperature at the inlet of the collector increased, the exergy gained by the water increased while the energy gained by the water decreased. The water temperature at the outlet of the collector could be calculated with a mean error of 2.8%, and the energy and the exergy could be calculated theoretically with mean errors of 16.8% and 19.1%, respcetively.

  • PDF

Thermal Concentration Characteristic of Flat Plate Solar Collector for Application on the Sea (해상적용 평판형 태양열 집열기의 집열특성)

  • Ji, M.K.;Jeong, H.M.;Chung, H.S.;Lee, C.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.9-16
    • /
    • 2000
  • This paper represents the heat storage performance of the flat plate solar collector. This research aims to application for fishing ship on the sea, and the solar collector has among of motions with pitching and rolling thus, this collector has to be a forced type circulation. In this research, we investigated the solar collector performance for the various collector tilt angle. As the experimental results with three types, we found that the S-type collector was excellent.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

The Effects of Water Flow Rates on the Performance of a Capillary Tube Solar Collector for Greenhouse Heating (온실 난방을 위한 모세관형 태양열 집열기의 성능에 미치는 유량의 효과에 관한 연구)

  • 유영선;장유섭;홍성기;윤진하;정두호;강영덕
    • Journal of Bio-Environment Control
    • /
    • v.5 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • To use effectively the solar energy in greenhouse heating, a high performance solar collector should be developed. And then the size of the solar collector and thermal storage tank should be determined through the calculation of heating load. The solar collector must be set in the optimum tilt angle and direction to take daily solar radiation maximally, and the flow rate of heat transfer fluid through the solar collector should be kept in the optimum range. In this research, the performance tests of a capillary tube solar collector were performed to determine the optimum water flow rate and the results summarized as follows. 1. The regressive equations for efficiency estimations of the capillary tube solar collector in the open loop were modeled in the water flow rate of 700-l,000 $\ell$/hr. 2. The optimum water flow rate of the solar collector was estimated by the second order polynomial regression and the maximum efficiency was 80% at the water flow rate of 850 $\ell$/hr. 3. The solar thermal storage system consisted of a capillary tube solar collector and a water storage tank was tested at the water flow rate of 850 $\ell$/hr in the closed loop, and obtained the solar thermal storage efficiency of 55.2%. 4. As the capillary tube solar collector engaged in this experiment was made of non-corrosive polyolefin tubes, its weight was as light as 1/30 of the flat plate solar collector made of copper tubes. Therefore it was considered to be suitable for the greenhouse heating system.

  • PDF

Study on Efficiency of Flat-Plate Solar Collector Using Nanofluids (나노유체를 이용한 평판형 태양열 집열기의 효율에 관한 연구)

  • Lee, Seung-Hyun;Jang, Seok Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.799-805
    • /
    • 2013
  • An analytical study is conducted to assess the efficiency of a flat-plate solar collector using nanofluids. The nondimensionalized 2D heat diffusion equation is solved by assuming a wavelength-independent extinction coefficient and intensity to obtain the analytical solution of the temperature distribution in the flat-plate solar collector. The dimensionless temperature distribution is investigated as functions of the volume fraction of the nanofluids, magnitude of heat loss, and collector's depth based on the analytical solution when using water-based single-walled carbon nanohorn (SWCNH) nanofluids as a working fluid. Finally, the efficiency of the flat-plate solar collector using the nanofluids is predicted and compared with that of the conventional solar collector. The results indicate that the efficiency of the nanofluid solar collector is better than that of the conventional solar collector under specific geometrical conditions.