• 제목/요약/키워드: solar heat collector

검색결과 253건 처리시간 0.024초

평판형 태양열 집열판의 집열관 온도분포 특성 (The Characteristics of Temperature Distributions for Flat Tube Type Solar Collector Type)

  • 모종근;배철환;정효민;정한식
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.85-91
    • /
    • 1999
  • This study represented experimental research on the flat-plate solar collector. The heat performances were measured the tube array surface temperature by thermal-couple. The solar collector($W{\times}H$) of $580{\times}1100$, various tilt angles of 30, 45, 60 degree and the internal tube number of 4, 6, 8, 10(ea) were utilized in the present investigation. It is found that the thermal concentration is higher as the tilt angle become larger and the solar tubes are more and more. In this stuby obtained results of following: The array of tubes in collector has the best nice in that the number of tube is eight and the tilt angle is 60 degree. The collect energy by each tube array shown high value by increase the number of tubes and tilt angles. In addition to, the collect energy depends on by the tilt angle than the number of tube.

  • PDF

지역별 기상조건과 급수온도에 따른 태양열 온수공급 시스템 성능에 관한 연구 (A Study on Performance of Solar Thermal System for Domestic Hot Water According to the Weather Conditions and Feedwater Temperatures at Different Locations in Korea)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.41-54
    • /
    • 2019
  • The purpose of this study is to analyze the performance of solar thermal system according to regional weather conditions and feedwater temperature. The performance analysis of the system was carried out for the annual and winter periods in terms of solar fraction, collector efficiency and it's optimal degree. The system is simulated using TRNSYS program for 6 cities, Seoul, Incheon, Gangneung, Mokpo, Gwangju, and Ulsan. Simulation results prove that the solar fraction of the system varies greatly from region to region, depending on weather conditions and feedwater temperatures. Monthly average solar fraction for winter season from November to February, a time when heat energy is most required, indicated that the highest is 73.6% in Gangnueng and the lowest is 56.9% in Seoul. This is about 30% relative difference between the two cities. On the other hand, the collector efficiency of the system for all six cities was analyzed in the range between 40% and 42%, indicating small difference compare to the solar fraction. The annual average solar fraction is rated the highest at 40 collector degree, while monthly average solar fraction during winter season is rated at 60 degree.

신재생에너지를 이용한 해수담수시스템 실증 연구 (Demonstration study of desalination system with renewable energy)

  • 주홍진;황인선;주문창;곽희열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.197.1-197.1
    • /
    • 2010
  • This study was carried out to evaluate the operating performances of the evaporation desalination system with solar energy. This system was designed to use evacuated solar collector as the heat source, supplying the required heat energy and photovoltaic power as the electric source, supplying required power to pumps in the desalination system. The 5kW photovoltaic power generation system to make the electricity, the single-stage fresh water generator with plate heat exchanger, and remote control and monitoring system. Solar desalination system was designed and installed in Jeju-island, Korea in 2006, after about 4 years of operation, usability and stability of solar desalination system was guaranteed. The system comprises of the desalination unit which was designed to have daily fresh water capacity of $2m^3$, a $120m^2$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity to hydraulic pumps for the heat medium fluids. On a clear day, average daily solar irradiance in Jeju-island was measured to be $500W/m^2$ and the daily fresh water yield showed to be more than 500 liters under this condition. After around three years of a long term operation of the system from January 2007 to August 2009, average daily freshwater yield was analyzed to be around $330{\ell}$. The relationship equation between solar irradiance and freshwater yield was found to be y=1.1806x - 107.89.

  • PDF

태양열 집열기 기능을 갖는 BIPV 시스템의 응용 (Application of BIPV System Functioned as Solar Collector)

  • 민성혜;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF

태양광열 시스템의 신뢰성 평가에 관한 연구 (A Study on the Reliability Assesment of Solar Photovoltaic and Thermal Collector System)

  • 박태국;배승훈;김상교;김선민;김대환;엄학용;이근휘
    • 신재생에너지
    • /
    • 제16권4호
    • /
    • pp.49-64
    • /
    • 2020
  • Photovoltaic and Thermal collector (PV/T) systems are renewable energy devices that can produce electricity and heat energy simultaneously using solar panels and heat exchangers. Since PV/T systems are exposed to the outdoors, their reliability is affected by various environmental factors. This paper presents a reliability test for a PV/T system and evaluates the test results. The reliability assessment entails performance, environment, safety, and life tests. The factor that had the greatest influence on the life of the system was the hydraulic pressure applied to the heat exchanger. A test was conducted by repeatedly applying pressure to the PV/T system, and a reliability analysis was conducted based on the test results. As a result, the shape parameter (β) value of 5.6658 and the B10life 308,577 cycles at the lower 95% confidence interval were obtained.

PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석 (The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector)

  • 어승희;이정빈;최윤성;김대현
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.1-10
    • /
    • 2012
  • A photovoltaic/thermal (PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of he glazed PVT system were57.9% and14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

태양열 실증 시스템의 냉방 및 급탕 일일 열성능 (Thermal performance of solar cooling and hot water for the demonstration system)

  • 이호;김상진;주홍진;곽희열
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.564-569
    • /
    • 2007
  • This study describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about 350㎡ was heated and cooled with the solar system. The system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, subsidiary tank, absorption chiller, chiller storage tank, and cooling tower. The results of the experimental study indicated that the total solar energy gain as daily performance on a sunny day (August 25, 2007) with total daily radiation of $606\;W/m^2$ was 671 kWh, the collecting efficiency of 55%. In the case of supplies to heat source more than $83^{\circ}C$, cooling time operated by solar was driven 8.8 hours, cooling energy generated by solar system was 179 kWh and the solar cooling fraction was 79.2%, and hot water supplied with surplus heat source by the solar system was 201 kWh.

  • PDF

PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석 (The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector)

  • 어승희;이정빈;최윤성;김대현
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.60-67
    • /
    • 2011
  • A photovoltaic/thermal(PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of the glazed PVT system were 57.9% and 14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system, it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was 72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

  • PDF

자연 대류식 태양열 집열기 (TAP)의 설계와 평가 (A Design of Thermosiphoning Air Panel and its Performance Analyzing)

  • 신희영;이경희
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.51-57
    • /
    • 1984
  • The aim of the study is to the thermal performance of TAP (Thermosiphoning Air Panel) which is easily applicable to existing building as well as new building. TAP is one of the advantageous means of passive solar system, with a view to reducing the energy consumption of existing and new building. The instantaneous thermal efficency of a thermo siphoning collector depends primarily on the heat loss coefficient of the collector, the effectiveness of heattransfer between the absorber and the air, the average air temperature in the collector, the ambient air temperature, and the transmitted solar radiation. Because the important design variables are interrelated, it is, difficult to determine the effect of design decisions based on intuition. Therefore economical and effective TAP can be used easily, TAP had been designed and analyzed.

  • PDF

액체식 태양열난방계통에 관한 연구 (A Study on the liquid Type Solar Heating System)

  • 남평우
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF