• 제목/요약/키워드: solar envelope

검색결과 85건 처리시간 0.023초

발코니형 BIPV시스템의 발전성능 향상을 위한 적용요소기술 분석 (Analysis of Application Elements for improvement in the generated electric power performance of balcony BIPV System)

  • 김현일;유권종;강기환;소정훈;이길송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2004
  • Photovoltaic(PV) technology is a popular part of building vocabulary. It can be used today on both existing and new buildings. Its use in the building envelope is very varied and open ways, such as roofing materials, facades, skylights and shading systems, for creative designers. So, to activate this systems demand appropriate sources of information, performance data of elements and design tools offering architects and designer. Therefore this paper describe application elements for BIPV system and then predict improvement in the generated electric power performance of balcony BIPV system.

  • PDF

상변화물질을 적용한 건축자재의 에너지절약 가능성 분석 (The Analysis of the Energy Saving Performances of Building Materials using Phase Change Materials)

  • 안상민;황석호;김태연;이승복
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.162-167
    • /
    • 2011
  • Thermal storage plays an important role in building energy saving, which is greatly assisted by the incorporation of latent heat storage in building materials. A phase change material is a substance with a high heat of fusion which, melting and solidifying at a certain temperature, can be storing and releasing large amount of energy. Heat is stored or released when the material changes from solid to liquid. Integration of building materials incorporating PCMs into the building envelope can result in increased efficiency of the built environment. The aim of this research is to identify thermal performance of PCMs impregnated building materials which is applied to interior of building such as gypsum and red clay. In order to analyze thermal performance of phase change materials, test-cell experiments and simulation analysis were carried out. The results show that micro-encapsulated PCM has an effect to maintain a constant indoor temperature using latent heat through the test-cell experiments. PCM wallboard makes it possible to reduce the fluctuation of room temperature and heating and cooling load by using EnergyPlus simulation program. Phase change material can store solar energy directly in buildings. Increasing the heat capacity of a building is capable of improving human comfort by decreasing the frequency of indoor air temperature swings so that the interior air temperature is closer to the desired temperature for a long period of time.

  • PDF

후면부재에 따른 BIPV 모듈의 특성 분석 (Characteristic Analysis of BIPV Module according to Rear Materials)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.28-33
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. Building integrated photovoltaic(BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influenced on the reflection by rear materials such as white back sheet and the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. In this study, to use as suitable building materials into environmentally friendly house like green home, characteristic analysis of BIPV module according to rear materials achieved. Electrical output of PV module with white back sheet is high about 10% compared to other pv module because of 83% reflectivity of white back sheet compared to 8.4% reflectivity of other PV modules with different rear materials(black back sheet and glass). In the result of outdoor experiment during a year, electrical output of four different PV module is decreased about 3.72%.

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

평판 및 모서리형 현장열저항 측정기기 개발을 위한 Computer Simulation (Computer Simulation for Developing the Plate and Corner Type In-Situ Thermal Resistance Measuring Device)

  • 강병웅;박승익;유승선;박효순
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.71-80
    • /
    • 1999
  • 본 연구는 예비실험에서 나타난 평판 및 모서리형 현장 열저항 측정기의 내부공기 온도편차를 줄일 수 있는 방안을 모색하기 위한 것으로 연구결과 다음과 같은 결론을 얻을 수 있었다. 첫째, 측정기의 크기에 따라 기기내의 온도편차는 큰 변화가 없으므로 사용과 운반이 용이한 소형이 적정하며 둘째, 방열판의 위치는 측정기 Casing을 통한 부수적인 손실열량을 최소화하기 위해 측정기 내부 표면과 이격시켜 설치하고 셋째, 방열판의 온도는 측정기내부온도가 실내온도까지 접근하는 도달시간을 고려하여 가능한 한 낮게 설정하고 넷째, 측정기 내부에 설치되는 팬은 측정기의 상부에 설치하여 기류를 하향으로 토출하며 다섯째, 방열판 앞에는 Baffle Plate를 설치하는 것이 기기내의 온도편차를 줄일 수 있는 유효한 방법임을 알 수 있었다.

  • PDF

실측 실험을 통한 단열문의 열성능 평가 (Thermal Performance Assessment of Insulated door by experiment.)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구 (The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test)

  • 김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

지역별 에너지 소요량과 생산량을 반영한 제로에너지건축물의 설계 방안에 관한 연구 (A Study on the Design Method of Zero Energy Building considering Energy Demand and Energy Generation by Region)

  • 이순명;이태규;김정욱
    • 대한건축학회논문집:계획계
    • /
    • 제34권8호
    • /
    • pp.13-22
    • /
    • 2018
  • The purpose of this study was to consider the energy generation of the building as well as the energy demand of the building in terms of zero energy building design. The reason why the zero energy building viewpoint should be discussed is that direction of the building, heat transfer rate of the building, and the S/V ratio of the building are variables related to energy demand and solar panels installed on the building roof and building envelope are variables related to energy generation. This study proceeded as follows; Firstly, the simulation model of large office and elementary school has the same mutual volume and total floor area, and the each floor area and number of floors are adjusted so that the S/V ratio is different. To the next, the energy demand and energy generation of the simulation model were derived based on the meteorological data of Seoul, Daejeon, Busan. Finally, energy demand, energy generation, and final energy demand were compared with heat transfer rate, S/V ratio, building type, region, and orientation. The results of this study is that consideration of solar power generation in terms of energy generation should be taken into consideration at the same time in consideration of the heat transfer rate, the shape, the region and the direction of the zero energy building design.

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

채층 활동이 강한 별들의 분광선 (SPECTRA OF CHROMOSPHERICALLY ACTIVE STARS)

  • 강영운;김호일;이우백;오규동
    • 천문학논총
    • /
    • 제15권spc1호
    • /
    • pp.93-102
    • /
    • 2000
  • We have reviewed the magnetic activity in close binaries. Solar like magnetic activity indicators such as photometric spots, chromo spheric emission, coronal X-ray and radio emission, and flare activity are commonplace in many cool stars with convective envelopes. Using the UV spectra we confirmed the strength of stellar activity increases with more rapid rotation and later spectral types which corresponds to the increasing depth of the star's convective envelope. Apart from very young stellar objects such as T Tauri stars, the stars with the highest levels of activity are close binary systems composed of cool stars, i.e., the chromospherically active binaries such as RS CVn, BY Dra, W UMa and related systems. The IUE low and high dispersion spectra of V711 Tau, VW Cep and SW Lac are used for ultraviolet photometry and for a variation study of chromospheric activity. Evidence of chromospherically activity is indicated by the intensity variation of the Mg II emission line with orbital phase.

  • PDF